Implications of in-use photostability: proposed guidance for photostability testing and labeling to support the administration of photosensitive pharmaceutical products, part 1: drug products administered by injection.

Basic guidance on the photostability testing of pharmaceuticals, designed to cover manufacturing and storage over shelf life, has long been established within ICH Q1(ICH,B(10) , but the guideline does not cover the photostability of drugs during or after administration (i.e., under conditions of use). To date, there has been a paucity of guidance covering the additional testing that would be of value during the clinical preparation and use of products. This commentary suggests a systematic approach, based on realistic "worst case" photoexposure scenarios and the existing ICH Option 1 and 2 light sources, to provide valuable data to pharmaceutical manufacturers and compounding pharmacists for the safe and effective use of photosensitive injection products.

[1]  W Aman,et al.  ICH guideline for photostability testing: aspects and directions for use. , 2003, Die Pharmazie.

[2]  I. Kjønniksen,et al.  Photodestabilization of epinephrine by sodium metabisulfite. , 2000, PDA journal of pharmaceutical science and technology.

[3]  S. Kristensen Photostability of Parenteral Products , 2004 .

[4]  J. Brustugun,et al.  Formation and reactivity of free radicals in 5-hydroxymethyl-2-furaldehyde--the effect on isoprenaline photostability. , 2005, Journal of photochemistry and photobiology. B, Biology.

[5]  N. Anderson,et al.  Photostability Testing: Design and Interpretation of Tests on New Drug Substances and Dosage Forms , 2004 .

[6]  P. Ineichen,et al.  A new operational model for satellite-derived irradiances: description and validation , 2002 .

[7]  Karen M. Alsante,et al.  A critical assessment of the ICH guideline on photostability testing of new drug substances and products (Q1B): Recommendation for revision. , 2010, Journal of pharmaceutical sciences.

[8]  Robert A Reed,et al.  The role of excipients and package components in the photostability of liquid formulations. , 2003, PDA journal of pharmaceutical science and technology.

[9]  J. Brustugun,et al.  Photostability of symphatomimetic agents in commonly used infusion media in the absence and presence of bisulfite. , 2004, PDA journal of pharmaceutical science and technology.

[10]  Edward H. Lee American society of health-system pharmacists. , 2011, P & T : a peer-reviewed journal for formulary management.

[11]  P Flesch,et al.  Light and Light Sources: High-Intensity Discharge Lamps , 2007 .

[12]  F. Sequeira,et al.  Photostability studies of drug substances and products practical implications of the ich guideline , 2000 .

[13]  S. R. Thatcher,et al.  Pharmaceutical photostability : A technical guide and practical interpretation of the ICH guideline and its application to pharmaceutical stability : Part II , 2001 .

[14]  E. L. Maxwell,et al.  High-resolution maps of solar collector performance using a climatological solar radiation model , 1999 .

[15]  Robert A. Reed,et al.  Implications of photostability on the manufacturing, packaging, storage, and testing of formulated pharmaceutical products , 2005 .