Adhesion patterns in the microvasculature are dependent on bifurcation angle.

Particle adhesion in vivo is highly dependent on the microvascular environment comprising of unique anatomical, geometrical, physiological fluid flow conditions and cell-particle and cell-cell interactions. Hence, proper design of vascular-targeted drug carriers that efficiently deliver therapeutics to the targeted cells or tissue at effective concentrations must account for these complex conditions observed in vivo. In this study, we build upon our previous results with the goal of characterizing the effects of bifurcations and their corresponding angle on adhesion of functionalized particles and neutrophils to activated endothelium. Our hypothesis is that adhesion is significantly affected by the type of biochemical interactions between particles and vessel wall as well as the presence of bifurcations and their corresponding angle. Here, we investigate adhesion of functionalized particles (2 μm and 7 μm microparticles) to protein coated channels as well as adhesion of human neutrophils to human endothelial cells under various physiological flow conditions in microfluidic bifurcating channels comprising of different contained angles (30°, 60°, 90°, or 120°). Our findings indicate that both functionalized particle and neutrophil adhesion propensity increase with a larger bifurcation angle. Moreover, the difference in the adhesion patterns of neutrophils and rigid, similar sized (7 μm) particles is more apparent in the junction regions with a larger contained angle. By selecting the right particle size range, enhanced targeted binding of vascular drug carriers can be achieved along with a higher efficacy at optimal drug dosage. Hence, vascular drug particle design needs to be tailored to account for higher binding propensity at larger bifurcation angles.

[1]  M. U. Nollert,et al.  Design Considerations for a Microfluidic Device to Quantify the Platelet Adhesion to Collagen at Physiological Shear Rates , 2009, Annals of Biomedical Engineering.

[2]  K. Pant,et al.  Generation of shear adhesion map using SynVivo synthetic microvascular networks. , 2014, Journal of visualized experiments : JoVE.

[3]  Phapanin Charoenphol,et al.  Margination propensity of vascular-targeted spheres from blood flow in a microfluidic model of human microvessels. , 2013, Langmuir : the ACS journal of surfaces and colloids.

[4]  S. Simon,et al.  Leukocyte Function Antigen-1, Kindlin-3, and Calcium Flux Orchestrate Neutrophil Recruitment during Inflammation , 2012, The Journal of Immunology.

[5]  D. J. Goetz,et al.  The N-terminal peptide of PSGL-1 can mediate adhesion to trauma-activated endothelium via P-selectin in vivo. , 2002, Blood.

[6]  D. Ku,et al.  Fluid mechanics of vascular systems, diseases, and thrombosis. , 1999, Annual review of biomedical engineering.

[7]  Flor A. Cianchetti,et al.  Development of a Method to Quantify Platelet Adhesion and Aggregation Under Static Conditions , 2014, Cellular and molecular bioengineering.

[8]  T. Karino,et al.  Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries. , 1990, Circulation research.

[9]  V. Odero-Marah,et al.  Snail negatively regulates cell adhesion to extracellular matrix and integrin expression via the MAPK pathway in prostate cancer cells , 2011, Cell adhesion & migration.

[10]  Leonie Rouleau,et al.  Neutrophil Adhesion on Endothelial Cells in a Novel Asymmetric Stenosis Model: Effect of Wall Shear Stress Gradients , 2010, Annals of Biomedical Engineering.

[11]  Jung Yeop Lee,et al.  Murray’s law and the bifurcation angle in the arterial micro-circulation system and their application to the design of microfluidics , 2009 .

[12]  Bin Wang,et al.  Preferential adhesion of leukocytes near bifurcations is endothelium independent. , 2010, Microvascular research.

[13]  J. Abe,et al.  Flow shear stress and atherosclerosis: a matter of site specificity. , 2011, Antioxidants & redox signaling.

[14]  R. Schroter,et al.  Atheroma and arterial wall shear - Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis , 1971, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[15]  Y. Cho,et al.  Experimental investigation of branch flow ratio, angle, and Reynolds number effects on the pressure and flow fields in arterial branch models. , 1985, Journal of biomechanical engineering.

[16]  Rakesh K Jain,et al.  Red blood cells augment leukocyte rolling in a virtual blood vessel. , 2002, Biophysical journal.

[17]  J. Marshall,et al.  Effect of particle collisions and aggregation on red blood cell passage through a bifurcation. , 2009, Microvascular research.

[18]  Noo Li Jeon,et al.  Vascular mimetics based on microfluidics for imaging the leukocyte--endothelial inflammatory response. , 2007, Lab on a chip.

[19]  Aliasger K Salem,et al.  Leukocyte-inspired biodegradable particles that selectively and avidly adhere to inflamed endothelium in vitro and in vivo , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[20]  Hiroki Fujiwara,et al.  Asymmetry of blood flow and cancer cell adhesion in a microchannel with symmetric bifurcation and confluence , 2011, Biomedical microdevices.

[21]  Y. Yeo,et al.  Development of quinic acid-conjugated nanoparticles as a drug carrier to solid tumors. , 2013, Biomacromolecules.

[22]  M. Jutila,et al.  Measurement of neutrophil adhesion under conditions mimicking blood flow. , 2007, Methods in molecular biology.

[23]  M. Lawrence,et al.  Microparticle adhesive dynamics and rolling mediated by selectin‐specific antibodies under flow , 2007, Biotechnology and bioengineering.

[24]  Kapil Pant,et al.  Microfluidic devices for modeling cell-cell and particle-cell interactions in the microvasculature. , 2011, Microvascular research.

[25]  M Ferrari,et al.  Flow chamber analysis of size effects in the adhesion of spherical particles , 2007, International journal of nanomedicine.

[26]  Samir Mitragotri,et al.  Using shape effects to target antibody-coated nanoparticles to lung and brain endothelium , 2013, Proceedings of the National Academy of Sciences.

[27]  Klaus Ley,et al.  Analysis of leukocyte rolling in vivo and in vitro. , 2006, Methods in enzymology.

[28]  T. Omori,et al.  CC-Chemokine receptor CCR7: a key molecule for lymph node metastasis in esophageal squamous cell carcinoma , 2014, BMC Cancer.

[29]  Yi Wang,et al.  Bifurcations: Focal Points of Particle Adhesion in Microvascular Networks , 2011, Microcirculation.

[30]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[31]  K. Pant,et al.  Bioinspired Microfluidic Assay for In Vitro Modeling of Leukocyte–Endothelium Interactions , 2014, Analytical chemistry.

[32]  Daniel A Hammer,et al.  Quantifying nanoparticle adhesion mediated by specific molecular interactions. , 2008, Langmuir : the ACS journal of surfaces and colloids.

[33]  Sudaxshina Murdan,et al.  Fabrication and in vivo evaluation of highly pH-responsive acrylic microparticles for targeted gastrointestinal delivery. , 2009, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[34]  Arnan Mitchell,et al.  A microfluidics device to monitor platelet aggregation dynamics in response to strain rate micro-gradients in flowing blood. , 2010, Lab on a chip.

[35]  Interactions between multiple cell types in parallel microfluidic channels: monitoring platelet adhesion to an endothelium in the presence of an anti-adhesion drug. , 2008, Analytical chemistry.

[36]  B. Prabhakarpandian,et al.  Expression and Functional Significance of Adhesion Molecules on Cultured Endothelial Cells in Response to Ionizing Radiation , 2001, Microcirculation.

[37]  Mauro Ferrari,et al.  The margination propensity of spherical particles for vascular targeting in the microcirculation , 2008, Journal of nanobiotechnology.

[38]  Yi Wang,et al.  Adhesive Interaction of Functionalized Particles and Endothelium in Idealized Microvascular Networks , 2013, Microvascular research.

[39]  G. Garcı́a-Cardeña,et al.  Vascular endothelium, hemodynamics, and the pathobiology of atherosclerosis. , 2013, Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology.

[40]  I. Sarelius,et al.  Distributions of Wall Shear Stress in Venular Convergences of Mouse Cremaster Muscle , 2003, Microcirculation.

[41]  M. Fahim Cardiovascular sensory receptors and their regulatory mechanisms. , 2003, Indian journal of physiology and pharmacology.

[42]  Samir Mitragotri,et al.  Flow and adhesion of drug carriers in blood vessels depend on their shape: a study using model synthetic microvascular networks. , 2010, Journal of controlled release : official journal of the Controlled Release Society.

[43]  Kapil Pant,et al.  A physiologically realistic in vitro model of microvascular networks , 2009, Biomedical microdevices.

[44]  D. Hammer,et al.  Sialyl LewisX-Mediated, PSGL-1-Independent RollingAdhesion on P-selectin , 2000 .

[45]  Phapanin Charoenphol,et al.  Potential role of size and hemodynamics in the efficacy of vascular-targeted spherical drug carriers. , 2010, Biomaterials.

[46]  D. Ku BLOOD FLOW IN ARTERIES , 1997 .

[47]  C. Zarins,et al.  Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress , 1983, Circulation research.

[48]  S. Chien,et al.  Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives. , 2011, Physiological reviews.