Instantaneous heartbeat detection using a cross-correlation based template matching for continuous wave radar systems

Instantaneous heartbeat detection is necessary for an optimal patient monitoring in healthcare centers. Whereas electrocardiogram (ECG) and ballistocardiogram (BCG), for instance, are established methods for real time monitoring nowadays, contact-free systems are appreciated. Herewith, a 24 GHz continuous wave (CW) radar system with an intelligent signal processing is presented. Common heartbeat detection algorithms use the fast Fourier transform (FFT), and therefore require an adequate observation time window and rather detect an averaged heart rate. The proposed algorithm in contrast accomplishes the detection of single heart beats directly in the time domain with an insignificant delay. The core of that algorithm is a template matching using the cross-correlation method. In this paper, after describing the radar system with the novel signal processing, the presented system is compared to a commercial ECG product.

[1]  Laura Anitori,et al.  FMCW radar for life-sign detection , 2009, 2009 IEEE Radar Conference.

[2]  Sneh Anand,et al.  Application of wavelets based multiresolution analysis to detect relevant points of interest from finger-tip photoplethesmography and pressure signal from the radial artery , 2008, 2008 Cairo International Biomedical Engineering Conference.

[3]  Glenn F. Engen,et al.  Application of an Arbitrary 6-Port Junction to Power-Measurement Problems , 1972 .

[4]  C.C. Lin,et al.  Heart rate detection in highly noisy handgrip electrocardiogram , 2008, 2008 Computers in Cardiology.

[5]  James C. Lin,et al.  Microwave sensing of physiological movement and volume change: a review. , 1992, Bioelectromagnetics.

[6]  J. H. Shin,et al.  Automatic ballistocardiogram (BCG) beat detection using a template matching approach , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Robert Weigel,et al.  A Compact, Versatile Six-Port Radar Module for Industrial and Medical Applications , 2013, J. Electr. Comput. Eng..

[8]  Changzhi Li,et al.  Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection , 2008, IMS 2008.

[9]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[10]  Shaolin Liao,et al.  A real-time heart rate analysis for a remote millimeter wave I-Q sensor , 2011, IEEE Transactions on Biomedical Engineering.

[11]  H.L. Chan,et al.  Heartbeat Detection Using Energy Thresholding and Template Match , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[12]  William Plowden The Compact , 2003 .

[13]  Robert Weigel,et al.  Six-Port Radar Sensor for Remote Respiration Rate and Heartbeat Vital-Sign Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[14]  O. Boric-Lubecke,et al.  A digital signal processor for Doppler radar sensing of vital signs , 2001, IEEE Engineering in Medicine and Biology Magazine.

[15]  Shintaro Izumi,et al.  Noise-tolerant instantaneous heart rate and R-peak detection using short-term autocorrelation for wearable healthcare systems , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).