Long-term results of total condylar knee arthroplasty.

From 1979 to 1984, 126 consecutive Total Condylar (Howmedica, Rutherford, NJ) knee arthroplasties were performed at a hospital in Taiwan, of which 64 knees were available for evaluation. The patients' average weight was 58 kg. The average Hospital for Special Surgery knee score at the latest follow-up was 86 points. Using revision for mechanical failure as an end point, the 20-year overall survival was 91.9%. The survival for the all-polyethylene tibial component was 96.4% and for the metal-backed tibial component was 88.4%. The difference was statistically significant (P < .001). We recommend the use of the more cost-effective and durable all-polyethylene tibial component for a primary cemented total knee arthroplasty, particularly in Asians with a relatively low weight and who are relatively inactive, especially in elderly people.

[1]  G. Scuderi**,et al.  Survivorship of cemented total knee arthroplasty. , 1997, Clinical orthopaedics and related research.

[2]  Kelly G. Vince,et al.  The Total Condylar Knee Prosthesis , 1991 .

[3]  W. F. Conway,et al.  Breakage of the patellar component of a kinematic total knee arthroplasty. A case report. , 1986, Orthopedics.

[4]  K. Heiple,et al.  Use of a total condylar knee prosthesis for treatment of osteoarthritis and rheumatoid arthritis. Long-term results. , 1988, The Journal of bone and joint surgery. American volume.

[5]  R. Bryan,et al.  Total knee arthroplasty with the kinematic condylar prosthesis. A ten-year follow-up study. , 1995, The Journal of bone and joint surgery. American volume.

[6]  J. Insall,et al.  The total condylar prosthesis. 10- to 12-year results of a cemented knee replacement. , 1989, The Journal of bone and joint surgery. British volume.

[7]  Terence J. Gioe,et al.  A Randomized Comparison of All-Polyethylene and Metal-Backed Tibial Components , 2000, Clinical orthopaedics and related research.

[8]  A. Lindstrand,et al.  Polyethylene failure in two total knees. Wear of thin, metal-backed PCA tibial components. , 1990, Acta orthopaedica Scandinavica.

[9]  R. Laskin Total condylar knee replacement in patients who have rheumatoid arthritis. A ten-year follow-up study. , 1990, The Journal of bone and joint surgery. American volume.

[10]  Takaichiro Suzuki,et al.  :A Ten-year Follow-up Study , 1981 .

[11]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[12]  J. Rand Comparison of metal-backed and all-polyethylene tibial components in cruciate condylar total knee arthroplasty. , 1993, The Journal of arthroplasty.

[13]  J. BotellaLlusiá,et al.  [Long-term results]. , 1983, Anales de la Real Academia Nacional de Medicina.

[14]  R. Scott,et al.  Failure of the metal-backed patellar component after total knee replacement. , 1988, The Journal of bone and joint surgery. American volume.

[15]  J. Insall,et al.  The total condylar prosthesis. , 1986, Clinical orthopaedics and related research.

[16]  L. Schaper,et al.  Results of All-Polyethylene Tibial Components as a Cost-Saving Technique , 2000, Clinical orthopaedics and related research.

[17]  A. Lombardi,et al.  Fracture/dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty. , 1988, The Journal of bone and joint surgery. American volume.

[18]  R. Scott,et al.  The patellofemoral component of total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[19]  T. Sculco,et al.  Total Condylar Knee Arthroplasty: A Long-Term Followup , 2001, Clinical orthopaedics and related research.

[20]  L. Dorr,et al.  Matched-pair analysis of all-polyethylene versus metal-backed tibial components. , 2001, The Journal of arthroplasty.

[21]  L. Dorr,et al.  Clinical Comparison of All‐Polyethylene and Metal‐Backed Tibial Components in Total Knee Arthroplasty , 1991, Clinical orthopaedics and related research.

[22]  E. Kaplan,et al.  Nonparametric Estimation from Incomplete Observations , 1958 .

[23]  M. Ritter,et al.  Postoperative alignment of total knee replacement. Its effect on survival. , 1994, Clinical orthopaedics and related research.

[24]  G. Scuderi**,et al.  Survivorship of cemented knee replacements. , 1989, The Journal of bone and joint surgery. British volume.

[25]  U. Frankl,et al.  Fracture of polyethylene of patellar component in total knee arthroplasty, diagnosed by arthroscopy. , 1989, The Journal of arthroplasty.

[26]  G. Gill,et al.  Total condylar knee arthroplasty. 16- to 21-year results. , 1999, Clinical orthopaedics and related research.

[27]  J L Lewis,et al.  A comparative evaluation of tibial component designs of total knee prostheses. , 1982, The Journal of bone and joint surgery. American volume.

[28]  M. Akagi,et al.  Improved range of flexion after total knee arthroplasty. The total condylar knee versus the KU knee. , 1997, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).

[29]  J. Elting,et al.  The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs. , 1998, The Journal of arthroplasty.

[30]  G. Scuderi**,et al.  The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. , 1995, The Journal of bone and joint surgery. American volume.

[31]  C. Ranawat,et al.  Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. , 1993, Clinical orthopaedics and related research.

[32]  S. Stern,et al.  Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. , 1992, The Journal of bone and joint surgery. American volume.

[33]  J. Liau,et al.  The incidence of revision of the metal component of total knee arthroplasties in different tibial-insert designs. , 2002, The Knee.

[34]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[35]  C. Ranawat,et al.  Total Condylar Knee Replacement: A 20-Year Followup Study , 2001, Clinical orthopaedics and related research.

[36]  F. C. Ewald The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. , 1989, Clinical orthopaedics and related research.

[37]  T. Wright,et al.  Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. , 1992, Clinical orthopaedics and related research.

[38]  G. Engh,et al.  Tibial insert undersurface as a contributing source of polyethylene wear debris. , 1997, Clinical orthopaedics and related research.