VOC emissions from a LIFE reference: Small chamber tests and factorial studies

Abstract A liquid-inner tube diffusion-film-emission (LIFE) reference was developed to quickly evaluate the performance of a chamber system for furniture/building material VOC emission tests. The reference has a constant emission rate determined by an analytical balance at typical temperature and relative humidity conditions, and is able to provide predictable concentrations in a chamber testing system. A 51 L stainless steel chamber was used to test the LIFE reference's performance at an air temperature of 23 °C with 50% RH. Factorial studies of the LIFE reference's emission under various temperatures (10 °C, 23 °C and 30 °C) and relative humidities (33%, 50% and 70%) showed that the emission rate is sensitive to the chamber environment. A numerical regression equation was developed to describe the impact of chamber temperature, relative humidity and their interaction on the reference's emission, with the difference between prediction and testing results of less than 6% at 23 °C and 30 °C.

[1]  F. Haghighat,et al.  Volatile organic compound (VOC) adsorption on material: influence of gas phase concentration, relative humidity and VOC type. , 2006, Indoor air.

[2]  Cynthia Howard-Reed,et al.  Diffusion-controlled reference material for volatile organic compound emissions testing: Pilot inter , 2011 .

[3]  Yinping Zhang,et al.  Influence of temperature on formaldehyde emission parameters of dry building materials , 2007 .

[4]  Qinqin Deng,et al.  Study on a new correlation between diffusion coefficient and temperature in porous building materials , 2009 .

[5]  S Kirchner,et al.  State-of-the-art in the measurement of volatile organic compounds emitted from building products: results of European interlaboratory comparison. , 1999, Indoor air.

[6]  Vyt Garnys Test Method: ASTM D5116 "Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Material/Products". , 2010 .

[7]  Yinping Zhang,et al.  A standard reference for chamber testing of material VOC emissions: Design principle and performance , 2012 .

[8]  Chi-Chi Lin,et al.  Evaluation of impact factors on VOC emissions and concentrations from wooden flooring based on chamber tests , 2009 .

[9]  Bernhard Rappenglück,et al.  The first VOC intercomparison exercise within the Global Atmosphere Watch (GAW) , 2006 .

[10]  Ashok J. Gadgil,et al.  Modeling Emissions of Volatile Organic Compounds from New Carpets , 1994 .

[11]  Jianshun Zhang,et al.  An experimental study of relative humidity effect on VOCs effective diffusion coefficient and parti , 2011 .

[12]  Hendrik Emons,et al.  New definitions on reference materials , 2006 .

[13]  M. Morris,et al.  A comparative study of selected sorbents for sampling of aromatic VOCs from indoor air , 2010 .

[14]  Peder Wolkoff,et al.  Impact of air velocity, temperature, humidity, and air on long-term voc emissions from building products , 1998 .

[15]  R. Corsi,et al.  Sorptive interactions between VOCs and indoor materials. , 2001, Indoor air.

[16]  J C Little,et al.  Diffusion-controlled reference material for VOC emissions testing: proof of concept. , 2010, Indoor air.

[17]  B. Andersson,et al.  Evaluation of adsorbents for sampling and quantitative analysis of microbial volatiles using thermal desorption-gas chromatography , 1995 .

[18]  Michael H. Kutner Applied Linear Statistical Models , 1974 .

[19]  V. Barnett,et al.  Applied Linear Statistical Models , 1975 .