Time-resolved SAXS measurements facilitated by online HPLC buffer exchange.

Small-angle X-ray scattering (SAXS) is a powerful technique to structurally characterize biological macromolecules in solution. Heterogeneous solutions are inherently challenging to study. However, since SAXS data from ideal solutions are additive, with careful computational analysis it may be possible to separate contributions from individual species present in solution. Hence, time-resolved SAXS (TR-SAXS) data of processes in development can be analyzed. Many reported TR-SAXS results are initialized by a sudden change in buffer conditions facilitated by rapid mixing combined with either continuous or stopped flow. In this paper a method for obtaining TR-SAXS data from systems where the reaction is triggered by removal of a species is presented. This method is based on fast buffer exchange over a short desalting column facilitated by an online HPLC (high-performance liquid chromatography) connected to the SAXS sample cell. The sample is stopped in the sample cell and the evolving reaction is followed. In this specific system the removal of phenol initiates a self-association process of long-acting insulin analogues. For this experiment, data were collected in time series while varying concentrations. The method can be generally applied to other systems where removal of a species or other changes in experimental conditions trigger a process.

[1]  Hye Yoon Park,et al.  Concordant exploration of the kinetics of RNA folding from global and local perspectives. , 2006, Journal of molecular biology.

[2]  Michael Wulff,et al.  Structural dynamics of light-driven proton pumps. , 2009, Structure.

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  A. R. Balkenende,et al.  An in Situ Study of Mesostructured CTAB−Silica Film Formation during Dip Coating Using Time-Resolved SAXS and Interferometry Measurements , 2002 .

[5]  U. Ribel,et al.  The Mechanism of Protraction of Insulin Detemir, a Long-Acting, Acylated Analog of Human Insulin , 2004, Pharmaceutical Research.

[6]  Dmitri I. Svergun,et al.  PRIMUS: a Windows PC-based system for small-angle scattering data analysis , 2003 .

[7]  Yoshiyuki Amemiya,et al.  Influence of nucleotide effectors on the kinetics of the quaternary structure transition of allosteric aspartate transcarbamylase. , 2005, Journal of molecular biology.

[8]  S Doniach,et al.  Characterization of transient intermediates in lysozyme folding with time-resolved small-angle X-ray scattering. , 1999, Journal of molecular biology.

[9]  John E. Johnson,et al.  Evidence that a local refolding event triggers maturation of HK97 bacteriophage capsid. , 2004, Journal of molecular biology.

[10]  Svend Havelund,et al.  Biochemical and Physiological Properties of a Novel Series of Long-Acting Insulin Analogs Obtained by Acylation with Cholic Acid Derivatives , 2006, Pharmaceutical Research.

[11]  T. Narayanan,et al.  Millisecond-range time-resolved small-angle x-ray scattering studies of micellar transformations. , 2002, Physical Review Letters.

[12]  Hye Yoon Park,et al.  Reconstructing three-dimensional shape envelopes from time-resolved small-angle X-ray scattering data. , 2008, Journal of applied crystallography.

[13]  S. Stupp,et al.  Spontaneous and X-ray–Triggered Crystallization at Long Range in Self-Assembling Filament Networks , 2010, Science.

[14]  Y. Amemiya,et al.  Stopped-flow apparatus for x-ray scattering at subzero temperature , 1989 .

[15]  Y. Amemiya,et al.  Protein globularization during folding. A study by synchrotron small-angle X-ray scattering. , 1996, Journal of Molecular Biology.

[16]  A. Raudino,et al.  Pressure-induced formation of diblock copolymer "micelles" in supercritical fluids. A combined study by small angle scattering experiments and mean-field theory. I. The critical micellization density concept. , 2004, The Journal of chemical physics.

[17]  P. Vachette,et al.  Detection and characterization of an intermediate conformation during the divalent ion-dependent swelling of tomato bushy stunt virus. , 2000, Cellular and molecular biology.

[18]  Pressure-induced formation of diblock copolymer "micelles" in supercritical fluids. A combined study by small angle scattering experiments and mean-field theory. II. Kinetics of the unimer-aggregate transition. , 2004, The Journal of chemical physics.

[19]  Stephan Polachowski,et al.  Chopper system for time resolved experiments with synchrotron radiation. , 2009, The Review of scientific instruments.

[20]  G. David,et al.  Combined sampler robot and high-performance liquid chromatography: a fully automated system for biological small-angle X-ray scattering experiments at the Synchrotron SOLEIL SWING beamline , 2009 .

[21]  Maxim V. Petoukhov,et al.  ATSAS 2.1, a program package for small‐angle scattering data analysis , 2006 .

[22]  Jesper Søndergaard Pedersen,et al.  A SAXS study of glucagon fibrillation. , 2009, Journal of molecular biology.

[23]  L. Benning,et al.  Quantification of initial steps of nucleation and growth of silica nanoparticles: An in-situ SAXS and DLS study , 2009 .

[24]  P. Højrup,et al.  Small angle X-ray scattering study of calreticulin reveals conformational plasticity. , 2008, Biochimica et biophysica acta.

[25]  Satoshi Takahashi,et al.  Time-resolved small-angle X-ray scattering investigation of the folding dynamics of heme oxygenase: implication of the scaling relationship for the submillisecond intermediates of protein folding. , 2006, Journal of molecular biology.

[26]  A. Chmielewski,et al.  Structural temperature transformation of the cellulose–water system using time-resolved SAXS , 2001 .