Mechanical performance and capillary water absorption of sewage sludge ash concrete (SSAC)

Disposal of sewage sludge from waste water treatment plants is a serious environmental problem of increasing magnitude. Waste water treatment generates as much as 70 g of dry solids per capita per day. Although one of the disposal solutions for this waste is through incineration, still almost 30% of sludge solids remain as ash. This paper presents results related to reuse of sewage sludge ash in concrete. The sludge was characterised for chemical composition (X-ray flourescence analysis), crystalline phases (X-ray diffraction analysis) and pozzolanic activity. The effects of incineration on crystal phases of the dry sludge were investigated. Two water/cement (W/C) ratios (0.55 and 0.45) and three sludge ash percentages (5%, 10% and 20%) per cement mass were used as filler. The mechanical performance of sewage sludge ash concrete (SSAC) at different curing ages (3, 7, 28 and 90 days) was assessed by means of mechanical tests and capillary water absorption. Results show that sewage sludge ash leads to a reduction in density and mechanical strength and to an increase in capillary water absorption. Results also show that SSAC with 20% of sewage sludge ash and W/C = 0.45 has a 28 day compressive strength of almost 30 MPa. SSAC with a sludge ash contents of 5% and 10% has the same capillary water absorption coefficient as the control concrete; as for the concrete mixtures with 20% sludge ash content, the capillary water absorption is higher but in line with C20/25 strength class concretes performance.

[1]  P. K. Mehta,et al.  REDUCING THE ENVIRONMENT IMPACT OF CONCRETE. CONCRETE CAN BE DURABLE AND ENVIRONMENTALLY FRIENDLY , 2001 .

[2]  I. Hwang,et al.  Characteristics of leachate from pyrolysis residue of sewage sludge. , 2007, Chemosphere.

[3]  M Glavind,et al.  GREEN CONCRETE - A LIFE CYCLE APPROACH , 2002 .

[4]  J. Baeyens,et al.  Enhancing the use of waste activated sludge as bio-fuel through selectively reducing its heavy metal content. , 2007, Journal of hazardous materials.

[5]  R. D Davis,et al.  The Impact of EU and UK Environmental Pressures on the Future of Sludge Treatment and Disposal , 1996 .

[6]  S L Sarkar,et al.  New Cements for Sustainability , 2003 .

[7]  J. E. Halliday,et al.  Hydration Chemistry of Sewage Sludge Ash Used as a Cement Component , 2011 .

[8]  A Van Brecht,et al.  Mass balance for POPs in hazardous and municipal solid waste incinerators. , 2010, Chemosphere.

[9]  K. Mun,et al.  Development and tests of lightweight aggregate using sewage sludge for nonstructural concrete , 2007 .

[10]  J. Monzó,et al.  Reuse of sewage sludge ashes (SSA) in cement mixtures: the effect of SSA on the workability of cement mortars. , 2003, Waste management.

[11]  Gianni Andreottola,et al.  Sludge Reduction Technologies in Wastewater Treatment Plants , 2010 .

[12]  E. Vázquez,et al.  PHYSICAL AND MECHANICAL PROPERTIES OF CONCRETE WITH ADDED DRY SLUDGE FROM A SEWAGE TREATMENT PLANT , 2004 .

[13]  Pierre Clastres,et al.  Technological and Environmental Behavior of Sewage Sludge Ash (SSA) in Cement-based Materials , 2007 .

[14]  Kazunori Shimura,et al.  Applicability of Controlled Low-Strength Materials with Incinerated Sewage Sludge Ash and Crushed-Stone Powder , 2011 .

[15]  R. Cioffi,et al.  Manufacture of artificial aggregate using MSWI bottom ash. , 2011, Waste management.

[16]  J. Baeyens,et al.  Reducing the Heavy Metal Content of Sewage Sludge by Advanced Sludge Treatment Methods , 2006 .

[17]  Yu-min Chang,et al.  Characteristics of PCDD/F content in fly ash discharged from municipal solid waste incinerators. , 2011, Journal of Hazardous Materials.

[18]  B. Lagerblad,et al.  The function of fillers in concrete , 2004 .

[19]  F. Torgal,et al.  Influence of physical and geometrical properties of granite and limestone aggregates on the durability of a C20/25 strength class concrete , 2006 .

[20]  A. Neville,et al.  PROPERTIES OF CONCRETE. 4TH AND FINAL EDITION , 1995 .

[21]  David E. Bloom,et al.  7 Billion and Counting , 2011, Science.

[22]  Gilles Mertens,et al.  Assessment of Pb-slag, MSWI bottom ash and boiler and fly ash for using as a fine aggregate in cement mortar. , 2008, Journal of hazardous materials.

[23]  C. Meyer The greening of the concrete industry , 2009 .

[24]  Anastasia Zabaniotou,et al.  Utilization of sewage sludge in EU application of old and new methods--A review , 2008 .

[25]  Mattias Olofsson,et al.  Environmental and economic assessment of sewage sludge handling options. , 2004 .

[26]  N. Rodríguez,et al.  Re-use of drinking water treatment plant (DWTP) sludge: Characterization and technological behaviour of cement mortars with atomized sludge additions , 2010 .

[27]  E. Vázquez,et al.  Durability of Concrete with Addition of Dry Sludge from Waste Water Treatment Plants , 2005 .

[28]  J Baeyens,et al.  The distribution of heavy metals during fluidized bed combustion of sludge (FBSC). , 2008, Journal of hazardous materials.

[29]  F. Van Puyvelde,et al.  Fluidized bed incineration of sewage sludge: a strategy for the design of the incinerator and the future for incinerator ash utilization , 1994 .

[30]  J. Werther,et al.  Modeling the adsorption of mercury in the flue gas of sewage sludge incineration , 2003 .

[31]  Xiaolu Guo,et al.  Utilization of municipal solid waste incineration fly ash for sulfoaluminate cement clinker production. , 2011, Waste management.

[32]  J. Baeyens,et al.  Correlation of PCDD/F Emissions with Operating Parameters of Municipal Solid Waste Incinerators , 2001, Journal of the Air & Waste Management Association.