Statistical Evaluation of Indoor Air Quality Parameters in Classrooms of a University

This study was carried out in order to determine the indoor air quality of the classrooms existing in university (Turkey). Relative humidity, temperature, carbon dioxide, radon, and particulate matters (PM0.5, PM1.0, PM2.5, PM5.0, and PM10) were taken into account as the parameters of indoor air quality measurements. The results obtained from the present work were interpreted by comparing them with the standards of different countries. The relations between all parameters were statistically examined by means of correlation and regression analysis in SPSS 17 statistical program. As a result, it was observed that indoor temperature was lower than the standards, yet carbon dioxide and PM values were higher than the upper limit, but relative humidity level was within comfort conditions. The average indoor radon concentrations were found to be below the recommended reference levels for International Commission on Radiological Protection (ICRP), yet it was seen that the results were relatively higher in comparison with the worldwide values. In addition, it was determined that there was a meaningful relation between outdoor relative humidity, indoor relative humidity, and particulate matters in different diameters. Some solutions were suggested for the treatment of the indoor air quality for each parameter.

[1]  Martin Branis,et al.  The effect of outdoor air and indoor human activity on mass concentrations of PM(10), PM(2.5), and PM(1) in a classroom. , 2005, Environmental research.

[2]  Jeff McLeod Evaluation of indoor air quality parameters and airborne fungal spore concentrations by season and type of HVAC system in a school building , 2008 .

[3]  D Faulkner,et al.  Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. , 2004, Indoor air.

[4]  Komalanathan Vimalanathan,et al.  The effect of indoor office environment on the work performance, health and well-being of office workers , 2014, Journal of Environmental Health Science and Engineering.

[5]  K. Pandey,et al.  Indoor Air Quality for Poor Families: New Evidence from Bangladesh , 2004, Indoor air.

[6]  Elena Bucur,et al.  Assessment of indoor air quality in a wooden church for preventive conservation , 2015 .

[7]  Chi-Chi Lin,et al.  Characterization of Indoor PM10, PM2.5, and Ultrafine Particles in Elementary School Classrooms: A Review , 2010 .

[8]  Taeyon Hwang,et al.  Assessment of Indoor Environmental Quality in Open-Plan Offices , 2013 .

[9]  V. Sharifi,et al.  Experimental Investigation of Indoor Air Pollutants in Residential Buildings , 2013 .

[10]  K. Naddafi,et al.  Perceived risk of exposure to indoor residential radon and its relationship to willingness to test among health care providers in Tehran , 2014, Journal of Environmental Health Science and Engineering.

[11]  S. Crow,et al.  Causes of Indoor Air Quality Problems in Schools: Summary of Scientific Research. Revised Edition. , 2000 .

[12]  R. S. Zimmerman Indoor Air Quality Guidelines for Pennsylvania Schools. , 1999 .

[13]  S. Tao,et al.  Carbonaceous Particulate Matter Air Pollution and Human Exposure from Indoor Biomass Burning Practices , 2012 .

[14]  ZhuYing,et al.  Indoor Air Quality in Kitchens in Rural China , 2016 .