Independent power producers (IPP) perspectives and experiences with WSCC requirements for generator model validation tests

After two regional blackouts in 1996, The Western Systems Coordinating Council (WSCC) instituted guidelines to verify that, for grid connected generators, the stated data represents accurate information that could reliably be used in the dynamic modeling of the system. This paper demonstrates an experience with the applications of WSCC's test guidelines to mid size units built and commissioned by independent power producers (IPPs). The paper addresses concerns with the excitation and voltage control systems and their limitations. An example of a generation unit connected at the end of a long line is discussed to demonstrate variances associated with testing and operating under extreme conditions. The concerns and issues discussed are of importance to IPPs beyond the WSCC's system as many other reliability councils are adopting rules similar to those established by WSCC.

[1]  M. M. Adibi,et al.  Reactive capability limitation of synchronous machines , 1994 .

[2]  H. Happ Power system control and stability , 1979, Proceedings of the IEEE.

[3]  J.R. Ribeiro Minimum Excitation Limiter Effects on Generator Response to System Disturbances , 1991, IEEE Power Engineering Review.

[4]  A. Panvini,et al.  Field assessment of generators reactive capability , 1995 .

[5]  J. A. Mallick,et al.  Modeling of Solid Rotor Turbogenerators Part I: Theory and Techniques , 1978, IEEE Transactions on Power Apparatus and Systems.

[6]  P. Kundur,et al.  Power system stability and control , 1994 .

[7]  J. C. Agee,et al.  Validation of mechanical governor performance and models using an improved system for driving ballhead motors , 1995 .

[8]  L. N. Hannett,et al.  Test and simulation of network dynamic response using SSFR and RTDR derived synchronous machine models , 1990 .

[9]  P. Dandeno Supplementary Definitions & Associated Test Methods for Obtaining Parameters for Synchronous Machine Stability Study Simulations , 1980, IEEE Transactions on Power Apparatus and Systems.

[10]  S.E.M. de Oliveira,et al.  Impact of under-excitation limit control on power system dynamic performance , 1995 .

[11]  L. Hannett,et al.  Determination of Synchronous Machine Electrical Characteristics by Test , 1983, IEEE Transactions on Power Apparatus and Systems.

[12]  G. K. Girgis,et al.  Verification of limiter performance in modern excitation control systems , 1995 .

[13]  A.J.P. Ramos,et al.  Performance of under excitation limiter of synchronous machines for system critical disturbances , 1997 .

[14]  F.P. de Mello,et al.  Derivation of synchronous machine parameters from tests , 1977, IEEE Transactions on Power Apparatus and Systems.

[15]  R. C. Schaefer,et al.  Minimum/maximum excitation limiter performance goals for small generation , 1995 .

[16]  Ali Keyhani,et al.  On-line synchronous machine parameter estimation from small disturbance operating data , 1995 .

[17]  M.E. Coultes,et al.  Synchronous Machine Models by Standstill Frequency Response Tests , 1981, IEEE Transactions on Power Apparatus and Systems.

[18]  S. Henschel,et al.  Noniterative synchronous machine parameter identification from frequency response tests , 1999 .

[19]  G. R. Berube,et al.  A utility perspective on under-excitation limiters , 1995 .

[20]  P.L. Dandeno,et al.  Development of Detailed Turbogenerator Equivalent Circuits from Standstill Frequency Response Measurements , 1981, IEEE Transactions on Power Apparatus and Systems.

[21]  P. Kundur,et al.  Adaptation and Validation of Turbogenerator Model Parameters Through On-Line Frequency Response Measurements , 1981, IEEE Transactions on Power Apparatus and Systems.

[22]  S. S. Choi,et al.  A technique for tuning under excitation limiters , 1999 .

[23]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[24]  J. D. Hurley,et al.  The adverse effects of excitation system VAr and power factor controllers , 1999 .

[25]  J. Hurley,et al.  Standstill Frequency Response Modeling and Evaluation by Field Tests on a 645 MVA Turbine Generator , 1981, IEEE Transactions on Power Apparatus and Systems.

[26]  L. Hannett,et al.  Validation of Synchronous Machine Models and Derivation of Model Parameters from Tests , 1981, IEEE Transactions on Power Apparatus and Systems.

[27]  N. E. Nilsson,et al.  Synchronous generator capability curve testing and evaluation , 1994 .

[28]  G. K. Girgis,et al.  Recommended models for overexcitation limiting devices. Discussion , 1995 .

[29]  Y. H. Ku,et al.  Electric Power System Dynamics , 1983 .