Fully printed metabolite sensor using organic electrochemical transistor

As conducting polymer based devices, organic electrochemical transistors (OECTs) are suited for printing process. The convenience of the screen-printing techniques allowed us to design and fabricate OECTs with a selected design and using different gate material. Depending on the material used, we were able to tune the transistor for different biological application. Ag/AgCl gate provided transistor with good transconductance, and electrochemical sensitivity to pH was provided by polyaniline ink. Finally, we validate the enzymatic sensing of glucose and lactate with a Poly(3,4-ethylene dioxythiophene) doped with poly(styrene sulfonate) (PEDOT:PSS) gate often used due to its biocompatible properties. The screen-printing process allowed us to fabricate a large amount of devices in a short period of time, using only commercially available grades of ink, showing by this way the possible transfer to industrial purpose.

[1]  Wouter Olthuis,et al.  Lactate biosensors: current status and outlook , 2013, Analytical and Bioanalytical Chemistry.

[2]  Wenzhao Jia,et al.  Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites. , 2014, The Analyst.

[3]  Dermot Diamond,et al.  Organic electrochemical transistor incorporating anionogel as solid state electrolyte for lactate sensing , 2012 .

[4]  Piero Cosseddu,et al.  Inkjet printing of transparent, flexible, organic transistors , 2011 .

[5]  George G. Malliaras,et al.  All-Plastic Electrochemical Transistor for Glucose Sensing Using a Ferrocene Mediator , 2009, Sensors.

[6]  George G. Malliaras,et al.  Enzymatic sensing with organic electrochemical transistors , 2008 .

[7]  David Nilsson,et al.  An all-organic sensor-transistor based on a novel electrochemical transducer concept printed electrochemical sensors on paper , 2002 .

[8]  P. Leleux,et al.  High transconductance organic electrochemical transistors , 2013, Nature Communications.

[9]  George G. Malliaras,et al.  Influence of Device Geometry on Sensor Characteristics of Planar Organic Electrochemical Transistors , 2010, Advanced materials.

[10]  Barbara Stadlober,et al.  Influence of geometry variations on the response of organic electrochemical transistors , 2013 .

[11]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[12]  Chi-An W. Emhoff,et al.  Lactate kinetics at the lactate threshold in trained and untrained men. , 2013, Journal of applied physiology.

[13]  B. Phypers,et al.  Lactate physiology in health and disease , 2006 .

[14]  Jonathan Rivnay,et al.  Organic Electrochemical Transistors with Maximum Transconductance at Zero Gate Bias , 2013, Advanced materials.

[15]  Henry S. White,et al.  Chemical derivatization of an array of three gold microelectrodes with polypyrrole: Fabrication of a molecule-based transistor , 1984 .

[16]  George G. Malliaras,et al.  Effect of the gate electrode on the response of organic electrochemical transistors , 2010 .

[17]  Babak A. Parviz,et al.  A contact lens with an integrated lactate sensor , 2012 .

[19]  Shirley Dex,et al.  JR 旅客販売総合システム(マルス)における運用及び管理について , 1991 .

[20]  George G. Malliaras,et al.  Optimization of organic electrochemical transistors for sensor applications , 2011 .

[21]  J. Windmiller,et al.  Electrochemical tattoo biosensors for real-time noninvasive lactate monitoring in human perspiration. , 2013, Analytical chemistry.

[22]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[23]  Ronald Österbacka,et al.  Printed all-polymer electrochemical transistors on patterned ion conducting membranes , 2010 .

[24]  Göran Gustafsson,et al.  Fast-switching all-printed organic electrochemical transistors , 2013 .

[25]  George G Malliaras,et al.  Integration of a surface-directed microfluidic system with an organic electrochemical transistor array for multi-analyte biosensors. , 2009, Lab on a chip.

[26]  Huanfen Yao,et al.  A contact lens with embedded sensor for monitoring tear glucose level. , 2011, Biosensors & bioelectronics.