Magnetically Shielded Miniature Hall Thruster: Development and Initial Testing

The scaling of magnetically shielded Hall thrusters to low-power is investigated through the development and fabrication of a 4 cm Hall thruster. During initial testing, the magnetically shielded miniature Hall thruster was operated at 275 V discharge voltage and 325 W discharge power. Inspection of the channel walls after testing suggests that the outer discharge channel wall was successfully shielded from high-energy ion erosion while the inner channel wall showed evidence of weaker shielding, likely due to magnetic circuit saturation. Scanning planar probe measurements taken at 4.4 cm and 10.8 cm downstream of the thruster face provided ion current density profiles. The ion current calculated by integrating these data was 1.04 A with a plume divergence half-angle of 30°. Swept retarding potential analyzer measurements taken at 80 cm axially downstream of the thruster measured the most probable ion voltage to be 252 V. The total thruster efficiency was calculated from probe measurements to be 43% (anode efficiency of 59%) corresponding to a thrust of 19 mN at a specific impulse of 1870 s. Discharge channel erosion rates were found to be approximately three orders of magnitude less than unshielded Hall thrusters, suggesting a significant increase in projected operational life.

[1]  A. Mathers,et al.  Demonstration of 10,400 Hours of Operation on a 4.5 kW Qualification Model Hall Thruster , 2010 .

[2]  I. Mikellides,et al.  Wear test of a magnetically shielded Hall thruster at 3000 seconds specific impulse IEPC-2013-033 , 2013 .

[3]  I. Mikellides,et al.  Design of a Laboratory Hall Thruster with Magnetically Shielded Channel Walls, Phase II: Experiments , 2012 .

[4]  I. Mikellides,et al.  Magnetic Shielding of the Acceleration Channel Walls in a Long-Life Hall Thruster , 2010 .

[5]  Jason D. Sommerville,et al.  Hall-effect thruster--Cathode coupling: The effect of cathode position and magnetic field topology , 2009 .

[6]  W. Hargus Near Exit Plane Velocity Field of 200 W Hall Thruster , 2003 .

[7]  I. Mikellides,et al.  Conducting Wall Hall Thrusters , 2013, IEEE Transactions on Plasma Science.

[8]  Jared M. Ekholm,et al.  E x B Measurements of a 200 W Xenon Hall Thruster , 2005 .

[9]  Noah Zachary Warner,et al.  Theoretical and experimental investigation of Hall thruster miniaturization , 2007 .

[10]  W. Hargus,et al.  Near Exit Plane Velocity Field of a 200-Watt Hall Thruster , 2008 .

[11]  Yevgeny Raitses,et al.  Parametric investigation of miniaturized cylindrical and annular Hall thrusters , 2001 .

[12]  Mariano Andrenucci,et al.  A Review of the Hall Thruster Scaling Methodology , 2007 .

[13]  I. Mikellides,et al.  Design of a Laboratory Hall Thruster with Magnetically Shielded Channel Walls, Phase III: Comparison of Theory with Experiment , 2012 .

[14]  Manuel Martinez-Sanchez,et al.  Hybrid Particle-in-Cell Erosion Modeling of Two Hall Thrusters , 2008 .

[15]  Alec D. Gallimore,et al.  Preliminary Plume Characterization of a Low-Power Hall Thruster Cluster , 2002 .

[16]  Y. Garnier,et al.  Low-energy xenon ion sputtering of ceramics investigated for stationary plasma thrusters , 1999 .

[17]  Robert S. Jankovsky,et al.  Test Results of a 200 W Class Hall Thruster , 1998 .

[18]  Yury A. Sharov,et al.  PLASMA ACCELERATOR WITH CLOSED ELECTRON DRIFT AND EXTENDED ACCELERATION ZONE. , 1972 .

[19]  A. Morozov,et al.  Fundamentals of Stationary Plasma Thruster Theory , 2000 .

[20]  I. Katz,et al.  Fundamentals of Electric Propulsion: Ion and Hall Thrusters , 2008 .

[21]  Mariano Andrenucci,et al.  HET Scaling Methodology: Improvement and Assessment , 2008 .

[22]  Yassir Azziz,et al.  Instrument development and plasma measurements on a 200-watt Hall thruster plume , 2003 .

[23]  M. Tartz,et al.  Sputter Yields of Carbon Materials under Xenon Ion Incidence , 2007 .

[24]  A. Morozov FOCUSING COLD QUASINEUTRAL BEAMS IN ELECTROMAGNETIC FIELDS , 1965 .

[25]  Alec D. Gallimore,et al.  Ion Voltage Diagnostics in the Far-Field Plume of a High-Specific Impulse Hall Thruster , 2013 .

[26]  I. Mikellides,et al.  Design of a Laboratory Hall Thruster with Magnetically Shielded Channel Walls, Phase I: Numerical Simulations , 2011 .

[27]  I. Mikellides,et al.  Magnetic Shielding of the Channel Walls in a Hall Plasma Accelerator , 2011 .

[28]  Bruce Pote,et al.  Development of low power Hall thrusters , 1999 .

[29]  B. M. Reid,et al.  The Influence of Neutral Flow Rate in the Operation of Hall Thrusters. , 2009 .

[30]  L. B. King,et al.  Hall-Effect Thruster--Cathode Coupling, Part I: Efficiency Improvements from an Extended Outer Pole , 2011 .

[31]  Dan M. Goebel,et al.  Magnetic shielding of walls from the unmagnetized ion beam in a Hall thruster , 2013 .

[32]  J. R. Shell,et al.  Optimizing the energy resolution of planar retarding potential analyzers , 1992 .

[33]  I. Mikellides,et al.  The Effectiveness of Magnetic Shielding in High-Isp Hall Thrusters , 2013 .

[34]  T. E. Sheridan How big is a small Langmuir probe , 2000 .

[35]  Boris B. Kadomtsev,et al.  Reviews of Plasma Physics , 2012 .

[36]  M. Cappelli,et al.  Experimental Characterization of a Micro-Hall Thruster , 2007 .