Respiratory impedance spectral estimation for digitally created random noise

Measurement of respiratory input mechanical impedance (Zrs) is noninvasive, requires minimal subject cooperation, and contains information related to mechanical lung function. A common approach to measure Zrs is to apply random noise pressure signals at the airway opening, measure the resulting flow variations, and then estimate Zrs using Fast-Fourier Transform (FFT) techniques. The goal of this study was to quantify how several signal processing issues affect the quality of a Zrs spectral estimate when the input pressure sequence is created digitally. Random noise driven pressure and flow time domain data were simulated for three models, which permitted predictions of Zrs characteristics previously reported from 0–4, 4–32, and 4–200 Hz. Then, the quality of the Zrs estimate was evaluated as a function of the number of runs ensemble averaged, windowing, flow signal-to-noise ratio (SNR), and pressure spectral magnitude shape |P(jω)|. For a |P(jω)| with uniform power distribution and a SNR<100, the 0–4 Hz and 4–200 Hz Zrs estimates for 10 runs were poor (minimum coherence γ2<0.75) particularly where Zrs is high. When the SNR>200 and 10 runs were averaged, the minimum γ2 >0.95. However, when |P(jω)| was matched to |Zrs|, γ2 > 0.91 even for 5 runs and a SNR of 20. For data created digitally with equally spaced spectral content, the rectangular window was superior to the Hanning. Finally, coherence alone may not be a reliable measure of Zrs quality because coherence is only an estimate itself. We conclude that an accurate estimate of Zrs is best obtained by matching |P(jω)| to |Zin| (subject and speaker) and using rectangular windowing.

[1]  J Richalet,et al.  Frequency response of the chest: modeling and parameter estimation. , 1975, Journal of applied physiology.

[2]  K P Van de Woestijne,et al.  Mechanical properties of lungs and chest wall during spontaneous breathing. , 1980, Journal of applied physiology: respiratory, environmental and exercise physiology.

[3]  B. Suki,et al.  Forced oscillatory impedance of the respiratory system at low frequencies. , 1986, Journal of applied physiology.

[4]  Brian E. Maki,et al.  Interpretation of the Coherence Function When Using Pseudorandom Inputs to Identify Nonlinear Systems , 1986, IEEE Transactions on Biomedical Engineering.

[5]  I. Hamberg,et al.  Evaporated Sn‐doped In2O3 films: Basic optical properties and applications to energy‐efficient windows , 1986 .

[6]  K. Lutchen,et al.  Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations. , 1988, Journal of applied physiology.

[7]  Z Hantos,et al.  An improved forced oscillatory estimation of respiratory impedance. , 1982, International journal of bio-medical computing.

[8]  E D Michaelson,et al.  Pulmonary mechanics by spectral analysis of forced random noise. , 1975, The Journal of clinical investigation.

[9]  R. L. Pimmel,et al.  Parameter Estipiates in a Five-Element Respiratory Mechanical Model , 1982, IEEE Transactions on Biomedical Engineering.

[10]  D. Speers,et al.  Frequency dependence of total respiratory resistance in early airway disease. , 2015, The American review of respiratory disease.

[11]  W A Zin,et al.  Respiratory resistance with histamine challenge by single-breath and forced oscillation methods. , 1986, Journal of applied physiology.

[12]  J. Mead,et al.  Contribution of compliance of airways to frequency-dependent behavior of lungs. , 1969, Journal of applied physiology.

[13]  J. Mead,et al.  Mechanical factors in distribution of pulmonary ventilation. , 1956, Journal of applied physiology.

[14]  K. Lutchen,et al.  Reliability of parameter estimates from models applied to respiratory impedance data. , 1987, Journal of applied physiology.

[15]  A. W. Brody,et al.  Oscillation mechanics of lungs and chest in man. , 1956, Journal of applied physiology.

[16]  F. Harris On the use of windows for harmonic analysis with the discrete Fourier transform , 1978, Proceedings of the IEEE.

[17]  Z. Hantos,et al.  Importance of low-frequency impedance data for reliably quantifying parallel inhomogeneities of respiratory mechanics , 1988, IEEE Transactions on Biomedical Engineering.