Neutral current reduction control for smart transformer under the imbalanced load in distribution system

Imbalanced loads arouse neutral current looping in the distribution system, which increases power loss and results in neutral potential variation. Compared to the conventional power transformer, the smart transformer (ST) has advantages on the downstream voltage regulation. Thus, this paper proposes a voltage control strategy based on ST to reduce the LV grid neutral current according with EN 50160 imbalanced voltage standard. The proposed control has been validated in the Matlab/Simulink, and the system performance under the proposed control has been simulated under the imbalanced loading profile in a 400 kVA, 10 kV/400 V distribution network. The results prove the proposed control can practically reduce the neutral current.

[1]  Marco Liserre,et al.  Voltage control strategies of smart transformer considering DC capacitor lifetime , 2017, IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society.

[2]  Marco Liserre,et al.  Reverse power flow control in a ST-fed distribution grid , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[3]  Marco Liserre,et al.  Increasing Integration of Wind Power in Medium Voltage Grid by Voltage Support of Smart Transformer , 2016 .

[4]  Marco Liserre,et al.  Smart Transformer-Fed Variable Frequency Distribution Grid , 2018, IEEE Transactions on Industrial Electronics.

[5]  Ke Zhou,et al.  The study of power electronic transformer on power flow control and voltage regulation in DC micro-grid , 2015, 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[6]  Marco Liserre,et al.  The Smart Transformer: Impact on the Electric Grid and Technology Challenges , 2016, IEEE Industrial Electronics Magazine.

[7]  Marco Liserre,et al.  Investigation on Common-Mode Voltage Suppression in Smart Transformer-Fed Distributed Hybrid Grids , 2018, IEEE Transactions on Power Electronics.

[8]  Marco Liserre,et al.  Frequency-Adaptive Control of Smart Transformer-Fed Distribution Grid , 2018 .

[9]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[10]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[11]  Sanjib Kumar Panda,et al.  Design of new control strategies for a four-leg three-phase inverter to eliminate the neutral current under unbalanced loads , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[12]  Terence O'Donnell,et al.  Dynamic demand minimization using a smart transformer , 2017, IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society.

[13]  Andrew Keane,et al.  Discrete elastic residential load response under variable pricing schemes , 2014, IEEE PES Innovative Smart Grid Technologies, Europe.

[14]  Math Bollen IEEE Richard Harold Kaufmann Award Call for Nominations , 2002 .

[15]  S. K. Panda,et al.  A novel four-leg three-phase inverter control strategy to reduce the data center thermal losses: Elimination of neutral current , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.