Experimental thermal performance evaluation of a horizontal ground-source heat pump system

The goal of the present study is to validate the effects of the parameters such as the buried depth of earth coupled heat exchanger, mass flow rate of the water-antifreeze solution and sewer water on the performance of a horizontal ground-source heat pump (GSHP) system used for space heating experimentally. The GSHP system connected to a test room with 16.24 m2 floor area in Firat University, Elazig (38.41° N, 39.14° E), Turkey, was designed and constructed. The heating and cooling loads of the test room were 2.5 and 3.1 kW at design conditions, respectively. The experimental results were obtained from November to April in heating season of 2002–2003. The average performance coefficients of the system (COPsys) for horizontal ground heat exchanger in the different trenches, at 1 and 2 m depths, were obtained to be 2.66 and 2.81, respectively. Results obtained from experimental measurement concluded that the horizontal GSHP systems can be used for Elazig, Turkey climatic conditions.

[1]  Yusuf Ali Kara,et al.  Evaluation of low temperature geothermal energy through the use of heat pump , 2001 .

[2]  V. D. Baxter,et al.  An optimized ground-coupled heat pump system design for northern climate applications , 1985 .

[3]  D. A. Ball,et al.  Design methods for ground: source heat pumps , 1983 .

[4]  Josua P. Meyer,et al.  A performance comparison between an air‐source and a ground‐source reversible heat pump , 2001 .

[5]  A. Demirbas Turkey's Geothermal Energy Potential , 2002 .

[6]  Josua P. Meyer,et al.  A techno-economic analytical comparison of the performance of air-source and horizontal-ground-source air-conditioners in South Africa , 1997 .

[7]  Thore Berntsson,et al.  Heat sources — technology, economy and environment , 2002 .

[8]  Lingen Chen,et al.  Ground heat exchanger temperature distribution analysis and experimental verification , 2002 .

[9]  David E. Johnson,et al.  Electric Circuit Analysis , 1989 .

[10]  Arif Hepbasli,et al.  Experimental study of a closed loop vertical ground source heat pump system , 2003 .

[11]  J. P. Holman,et al.  Experimental methods for engineers , 1971 .

[12]  Arif Hepbasli,et al.  Geothermal energy utilization in Turkey , 2001 .

[13]  Stephen P. Kavanaugh,et al.  Ground Source Heat Pumps : Design of Geothermal Systems for Commercial and Institutional Buildings , 1997 .

[14]  Kamil Kaygusuz,et al.  Experimental and theoretical investigation of a solar heating system with heat pump , 2000 .

[15]  A Aittomäki,et al.  Effect of soil type and moisture content on ground heat pump performance , 1998 .

[16]  V. I. Ugursal,et al.  Performance and economic feasibility of ground source heat pumps in cold climate , 1997 .

[17]  Paul J. Lienau Geothermal Heat Pump Performance and Utility Programs in the United States , 1997 .

[18]  J. E. Bose,et al.  Design/data manual for closed-loop ground-coupled heat pump systems , 1985 .

[19]  Kamil Kaygusuz,et al.  Geothermal Energy: Power for a Sustainable Future , 2002 .

[20]  Arif Hepbasli,et al.  Energy and exergy analysis of a ground source (geothermal) heat pump system , 2004 .