Near-field probing of vibrational absorption for chemical microscopy

Identification of chemical compounds by vibrational spectroscopy at infrared wavelengths requires macroscopic samples: the spatial resolution is diffraction-limited to a scale of about half the wavelength, or about five micrometres. The scanning near-field optical microscope,, however, can reveal sub-wavelength detail because it uses near-field probing rather than beam focusing. Here we demonstrate the use of the aperture-less approach to scanning near-field optical microscopy to obtain contrast in vibrational absorption on a scale of about 100 nanometres, about one-hundredth of a wavelength. We record infrared scattering from the tip of an atomic force microscope scanned over a composite polymer film. At the boundary between different polymers we observe contrast changes owing to changes in vibrational absorption. The contrast is strongly enhanced in the near field of the probe tip, which we interpret as evidence of surface-enhanced infrared absorption. When extended to multi-wavelength operation, this approach should enable imaging of chemical composition at nanometre resolution.

[1]  W. Denk,et al.  Optical stethoscopy: Image recording with resolution λ/20 , 1984 .

[2]  C. Licoppe,et al.  Imaging and local infrared spectroscopy with a near field optical microscope , 1996 .

[3]  A. Liu,et al.  Prediction of New Low Compressibility Solids , 1989, Science.

[4]  W. Steen Absorption and Scattering of Light by Small Particles , 1999 .

[5]  M. Isaacson,et al.  Development of a 500 Å spatial resolution light microscope: I. light is efficiently transmitted through λ/16 diameter apertures , 1984 .

[6]  A. Zunger,et al.  CORRIGENDUM: Momentum-space formalism for the total energy of solids , 1979 .

[7]  John E. Wessel,et al.  Surface-enhanced optical microscopy , 1985 .

[8]  T. D. Harris,et al.  Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale , 1991, Science.

[9]  H. Walther,et al.  Detection of local conductivity by laser‐frequency mixing in a scanning force microscope , 1993 .

[10]  Warren E. Pickett,et al.  Pseudopotential methods in condensed matter applications , 1989 .

[11]  F. Keilmann,et al.  Contrast of microwave near-field microscopy , 1997 .

[12]  F. Keilmann,et al.  Scanning microscopy by mid-infrared near-field scattering , 1998 .

[13]  J. Gilman The Plastic Resistance of Crystals , 1960 .

[14]  John J. Gilman,et al.  Physical chemistry of intrinsic hardness , 1996 .

[15]  A. Boccara,et al.  Infrared-reflection-mode near-field microscopy using an apertureless probe with a resolution of lambda/600. , 1996, Optics letters.

[16]  E. Ash,et al.  Super-resolution Aperture Scanning Microscope , 1972, Nature.

[17]  Y. Martin,et al.  Scanning Interferometric Apertureless Microscopy: Optical Imaging at 10 Angstrom Resolution , 1995, Science.

[18]  H. Ledbetter,et al.  Mechanical hardness: A semiempirical theory based on screened electrostatics and elastic shear , 1998 .

[19]  David M. Teter,et al.  Computational Alchemy: The Search for New Superhard Materials , 1998 .

[20]  E. Korte,et al.  Surface enhanced infrared absorption observed with attenuated total reflection (ATR-SEIRA): modeling the optical response , 1998 .