Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo.

The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS= approximately 3mm, range: 38-63 mm; pennation angle: RMS= approximately 1.5 degrees, range: 22-32 degrees). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length approximately six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.

[1]  K. An,et al.  Repeated measures of adult normal walking using a video tracking system 1 Presented in part at the 1 , 1997 .

[2]  G. Lichtwark,et al.  Interactions between the human gastrocnemius muscle and the Achilles tendon during incline, level and decline locomotion , 2006, Journal of Experimental Biology.

[3]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  T. Fukunaga,et al.  In vivo behaviour of human muscle tendon during walking , 2001, Proceedings of the Royal Society of London. Series B: Biological Sciences.

[5]  P. Cerretelli,et al.  In vivo human gastrocnemius architecture with changing joint angle at rest and during graded isometric contraction. , 1996, The Journal of physiology.

[6]  Peter A Huijing,et al.  Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry , 2009, Muscle & nerve.

[7]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  O Maïsetti,et al.  Homogeneity and reproducibility of in vivo fascicle length and pennation determined by ultrasonography in human vastus lateralis muscle , 2006 .

[9]  C. Maganaris,et al.  Influence of gait velocity on gastrocnemius muscle fascicle behaviour during stair negotiation. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  Yasuo Kawakami,et al.  In vivo determination of fascicle curvature in contracting human skeletal muscles. , 2002, Journal of applied physiology.

[11]  D. Downham,et al.  How to assess the reliability of measurements in rehabilitation. , 2005, American journal of physical medicine & rehabilitation.

[12]  Jim Dowling,et al.  The effect of ultrasound probe orientation on muscle architecture measurement. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[13]  T. Fukunaga,et al.  Determination of fascicle length and pennation in a contracting human muscle in vivo. , 1997, Journal of applied physiology.

[14]  P Devos,et al.  Statistical tools for clinical gait analysis. , 2004, Gait & posture.

[15]  U. Croce,et al.  A kinematic and kinetic comparison of overground and treadmill walking in healthy subjects. , 2007, Gait & posture.

[16]  M. Bobbert,et al.  Mechanics of human triceps surae muscle in walking, running and jumping. , 2002, Acta physiologica Scandinavica.

[17]  C. Maganaris,et al.  In vivo measurements of the triceps surae complex architecture in man: implications for muscle function , 1998, The Journal of physiology.

[18]  L. Ardigò,et al.  Gastrocnemius muscle–tendon behaviour during walking in young and older adults , 2007, Acta physiologica.

[19]  G. Lichtwark,et al.  Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running. , 2007, Journal of biomechanics.

[20]  T. M. Wood,et al.  Measurement Concepts in Physical Education and Exercise Science , 1989 .