Classification of ECG signal with Support Vector Machine Method for Arrhythmia Detection

An electrocardiogram is a potential bioelectric record that occurs as a result of cardiac activity. QRS Detection with zero crossing calculation is one method that can precisely determine peak R of QRS wave as part of arrhythmia detection. In this paper, two experimental scheme (2 minutes duration with different activities: relaxed and, typing) were conducted. From the two experiments it were obtained: accuracy, sensitivity, and positive predictivity about 100% each for the first experiment and about 79%, 93%, 83% for the second experiment, respectively. Furthermore, the feature set of MIT-BIH arrhythmia using the support vector machine (SVM) method on the WEKA software is evaluated. By combining the available attributes on the WEKA algorithm, the result is constant since all classes of SVM goes to the normal class with average 88.49% accuracy.

[1]  Sweta Sneha,et al.  A wireless ECG monitoring system for pervasive healthcare , 2007, Int. J. Electron. Heal..

[2]  Álvaro Alesanco Iglesias,et al.  Clinical Assessment of Wireless ECG Transmission in Real-Time Cardiac Telemonitoring , 2010, IEEE Transactions on Information Technology in Biomedicine.

[3]  G Martinelli,et al.  Telecardiology: One-lead electrocardiogram monitoring and nurse triage in chronic heart failure , 2005, Journal of telemedicine and telecare.

[4]  Balázs Benyó,et al.  An open architecture patient monitoring system using standard technologies , 2002, IEEE Transactions on Information Technology in Biomedicine.

[5]  Arjon Turnip,et al.  Adaptive Principal Component Analysis Based Recursive Least Squares for Artifact Removal of EEG Signals , 2014 .

[6]  A. Martinez,et al.  A Home Telecare Management System , 1994, Computers in Cardiology 1994.

[7]  Heng-Ming Tai,et al.  Adaptive Noise Cancellation Algorithm for Speech Processing , 2007, IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society.

[8]  Lui Sha,et al.  A Medical-Grade Wireless Architecture for Remote Electrocardiography , 2011, IEEE Transactions on Information Technology in Biomedicine.

[9]  Steve Baker,et al.  Building reliability into your digital telemetry system. , 2002, Health management technology.

[10]  Arjon Turnip Artifacts Removal of EEG Signals Using Nonlinear Adaptive Autoregressive , 2015 .

[11]  P. Johnson,et al.  Remote Continuous Physiological Monitoring in the Home , 1996, Journal of telemedicine and telecare.

[12]  Upkar Varshney,et al.  Pervasive Healthcare Computing: EMR/EHR, Wireless and Health Monitoring , 2009 .

[13]  Witold Pedrycz,et al.  ECG signal processing, classification, and interpretation : , 2012 .

[14]  Nada Golmie,et al.  Prevailing over wires in healthcare environments: benefits and challenges , 2006, IEEE Communications Magazine.

[15]  Upkar Varshney Pervasive healthcare computing , 2009 .