The CRESS checklist for reporting stability studies: on behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)

Abstract To ensure that clinical laboratories produce results that are both accurate and of clinical utility it is essential that only samples of adequate quality are analysed. Although various studies and databases assessing the stability of analytes in different settings do exist, guidance on how to perform and report stability studies is lacking. This results in studies that often do not report essential information, thus compromising transferability of the data. The aim of this manuscript is to describe the Checklist for Reporting Stability Studies (CRESS) against which future studies should be reported to ensure standardisation of reporting and easy assessment of transferability of studies to other healthcare settings. The EFLM WG-PRE (European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase) produced the CRESS checklist following a detailed literature review and extensive discussions resulting in consensus agreement. The checklist consists of 20 items covering all the aspects that should be considered when producing a report on a stability study including details of what should be included for each item and a rationale as to why. Adherence to the CRESS checklist will ensure that studies are reported in a transparent and replicable way. This will allow other laboratories to assess whether published data meet the stability criteria required in their own particular healthcare scenario. The EFLM WG-PRE encourage researchers and authors to use the CRESS checklist as a guide to planning stability studies and to produce standardised reporting of future stability studies.

[1]  J. Pum,et al.  Evaluating sample stability in the clinical laboratory with the help of linear and non-linear regression analysis , 2019, Clinical chemistry and laboratory medicine.

[2]  H. Sachdev,et al.  Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples , 2019, Biochemia medica.

[3]  M. Milić,et al.  Croatian Society of Medical Biochemistry and Laboratory Medicine: National recommendations for blood collection, processing, performance and reporting of results for coagulation screening assays prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen and D-dimer , 2019, Biochemia medica.

[4]  L. Nonkes,et al.  Improving home haemodialysis: Stability evaluation of routine clinical chemistry analytes in blood samples of haemodialysis patients , 2019, Biochemia medica.

[5]  R. Cugat,et al.  Changes of salivary biomarkers under different storage conditions: effects of temperature and length of storage , 2019, Biochemia medica.

[6]  J. Pum Evaluating sample stability in the clinical laboratory with the help of linear and non-linear regression analysis. , 2019, Clinica chimica acta; international journal of clinical chemistry.

[7]  A. Šimundić,et al.  Joint EFLM-COLABIOCLI Recommendation for venous blood sampling , 2018, Clinical chemistry and laboratory medicine.

[8]  A. Šimundić,et al.  Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes , 2018, Clinical chemistry and laboratory medicine.

[9]  A. Šimundić,et al.  Call for more transparency in manufacturers declarations on serum indices: On behalf of the Working Group for Preanalytical Phase (WG-PRE), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). , 2018, Clinica chimica acta; international journal of clinical chemistry.

[10]  V. Álvarez,et al.  Laboratory sample stability. Is it possible to define a consensus stability function? An example of five blood magnitudes , 2018, Clinical chemistry and laboratory medicine.

[11]  David E Bruns,et al.  Smartphones Can Monitor Medical Center Pneumatic Tube Systems. , 2016, Clinical chemistry.

[12]  Christopher-John L Farrell,et al.  Serum indices: managing assay interference , 2016, Annals of clinical biochemistry.

[13]  A. Šimundić,et al.  Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes , 2016, Clinical chemistry and laboratory medicine.

[14]  Jérémie F. Cohen,et al.  STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies. , 2015, Clinical chemistry.

[15]  Sverre Sandberg,et al.  Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine , 2015, Clinical chemistry and laboratory medicine.

[16]  Sverre Sandberg,et al.  A checklist for critical appraisal of studies of biological variation , 2015, Clinical chemistry and laboratory medicine.

[17]  A. Dirican,et al.  Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions , 2012, Biochemia medica.

[18]  H. Portugal,et al.  Stability study of 81 analytes in human whole blood, in serum and in plasma. , 2012, Clinical biochemistry.

[19]  S. Carley,et al.  An introduction to power and sample size estimation , 2003, Emergency medicine journal : EMJ.

[20]  J. H. Lumsden,et al.  Laboratory test method validation , 2000 .