Effects of Attenuation and Scatter Corrections in Cat Brain PET Images Using microPET R4 Scanner

Purpose: The aim of this study was to examine the effects of attenuation correction (AC) and scatter correction (SC) on the quantification of PET count rates. Materials and Methods: To assess the effects of AC and SC -FDG PET images of phantom and cat brain were acquired using microPET R4 scanner. Thirty-minute transmission images using source and emission images after injection of FDG were acquired. PET images were reconstructed using 2D OSEM. AC and SC were applied. Regional count rates were measured using ROIs drawn on cerebral cortex including frontal, parietal, and latral temporal lobes and deep gray matter including head of caudate nucleus, putamen and thalamus for pre- and post-AC and SC images. The count rates were then normalized with the injected dose per body weight. To assess the effects of AC, count ratio of "deep gray matter/cerebral cortex" was calculated. To assess the effects of SC, ROIs were also drawn on the gray matter (GM) and white matter (WM), and contrast between them ((GM-WM)/GM was measured. Results: After the AC, count ratio of "deep gray matter/cerebral cortex" was increased by . After the SC, contrast was also increased by . Conclusion: Relative count of deep gray matter and contrast between gray and white matters were increased after AC and SC, suggesting that the AC would be critical for the quantitative analysis of cat brain PET data.

[1]  Roberto Accorsi,et al.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging—a simulation study , 2005, Physics in medicine and biology.

[2]  Martin G Pomper,et al.  Small animal imaging in drug development. , 2005, Current pharmaceutical design.

[3]  Jürgen Seidel,et al.  First results from the high-resolution mouseSPECT annular scintillation camera , 2005, IEEE Transactions on Medical Imaging.

[4]  Ronald J. Jaszczak,et al.  Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation , 2005, IEEE Transactions on Medical Imaging.

[5]  André Constantinesco,et al.  Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Patrick L Chow,et al.  Attenuation correction for small animal PET tomographs , 2005, Physics in medicine and biology.

[7]  S. Cherry,et al.  Physics in Nuclear Medicine , 2004 .

[8]  John Missimer,et al.  Performance evaluation of the 16-module quad-HIDAC small animal PET camera. , 2004, Physics in medicine and biology.

[9]  Tim Mulnix,et al.  PET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Tim Mulnix,et al.  NEMA NU 2 performance tests for scanners with intrinsic radioactivity. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Masaaki Tanaka,et al.  Assessment of microPET performance in analyzing the rat brain under different types of anesthesia: comparison between quantitative data obtained with microPET and ex vivo autoradiography , 2003, NeuroImage.

[12]  R. N. Goble,et al.  Performance evaluation of the microPET R4 PET scanner for rodents , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  R. Leahy,et al.  Transmission imaging and attenuation correction for the microPET/spl reg/ P4 tomograph , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[14]  R. N. Goble,et al.  Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. , 2001, Physics in medicine and biology.

[15]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[16]  S. Cherry,et al.  MicroPET: a high resolution PET scanner for imaging small animals , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[17]  B F Hutton,et al.  Simultaneous emission and transmission measurements for attenuation correction in whole-body PET. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  T. Turkington,et al.  An evaluation of post-injection transmission measurement in PET , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.