An evaluation of the Amputee Mobility Aid (AMA) early walking aid

The most popular early walking aid (EWA) in the United Kingdom (UK) is the Pneumatic PostAmputation Mobility aid or PPAM aid. A disadvantage of this device is that it does not allow a transtibial amputee to flex or extend the knee during walking. The Amputee Mobility Aid (AMA) was developed to allow knee movement, enabling transtibial amputees to practise a more natural gait. The benefits of using EWAs include early walking, reduction in postoperative oedema and improvement in patient morale. This pilot study investigated the pneumatic bag/stump interface pressures of the PPAM aid and the AMA. In addition, the range of motion of the knee on the amputated side and the mechanical knee of the AMA were compared. The AMA was found to have higher interface pressures than the PPAM aid during standing and similar pressures during supported walking. Subjects using the AMA did flex and extend their knee during walking but through a reduced range of motion. There were no significant differences between the angular movements of the AMA's mechanical knee and the patient's knee within it.

[1]  J. Barbenel Measurement of interface pressures , 1983 .

[2]  Green Rf,et al.  Pneumatic Airleg prosthesis: report of 200 cases. , 1982 .

[3]  E. Burgess,et al.  Progression of weight bearing after immediate prosthesis fitting following below-knee amputation. , 1971, Archives of physical medicine and rehabilitation.

[4]  J. Little THE USE OF AIR SPLINTS AS IMMEDIATE PROSTHESES AFTER BELOW‐KNEE AMPUTATION FOR VASCULAR INSUFFICIENCY , 1970, The Medical journal of Australia.

[5]  S. Pocock,et al.  Clinical Trials: A Practical Approach , 1984 .

[6]  R. Rausch,et al.  Air splint in preprosthetic rehabilitation of lower extremity amputated limbs. A clinical report. , 1985, Physical therapy.

[7]  K. Robinson,et al.  Post‐amputation pneumatic walking aid , 1978, The British journal of surgery.

[8]  J. M. Little,et al.  EXPERIENCE WITH A PNEUMATIC LOWER‐LIMB PROSTHESIS , 1972, The Medical journal of Australia.

[9]  F. Bonner,et al.  Pneumatic Airleg prosthesis: report of 200 cases. , 1982, Archives of physical medicine and rehabilitation.

[10]  J. Little A pneumatic weight-bearing temporary prosthesis for below-knee amputees. , 1971, Lancet.

[11]  R. Dickstein,et al.  The pneumatic post-amputation mobility aid in geriatric rehabilitation. , 1982, Scandinavian journal of rehabilitation medicine.

[12]  E. Condie,et al.  A One-year National Survey of Patients Having a Lower Limb Amputation , 1996 .

[13]  M. Kerstein Utilization of an air splint after below-knee amputation. , 1973, American journal of physical medicine.

[14]  Karpovich Pv,et al.  Electrogoniometric study of joints. , 1960 .

[15]  Knee Recurvatum in Gait: A Study of Associated Knee Biomechanics , 1996 .

[16]  J. H. Evans,et al.  Interface Pressure Sensors: Existing Devices, Their Suitability And Limitations , 1976 .

[17]  M. Sher The air splint. An alternative to the immediate postoperative prosthesis. , 1974, Archives of surgery.