Measurements and characterization of power transformer and low voltage access network for NB‐PLC

Correspondence Bilal Masood, COMSATS Institute of Information Technology, Lahore, Pakistan. Email: bilal.masood@superior.edu.pk Summary Several techniques for a state-of-the-art advanced metering infrastructure (AMI) within the smart grid are being extensively studied and evaluated around the world. Advanced metering infrastructure provides an enhanced and efficient energy management infrastructure that can facilitate the latest demands of electric utilities, consumers, and smart grid. In the past few years, standardization process for the implementation of AMI using narrowband power line communications (NB-PLC) transceivers has been completed by ITU-T and IEEE. This paper is focused on the utilization of CENELEC band of NB-PLC for deployment aspects. The power transformer model of 200 and 75 kVA transformers for 9 to 90 kHz frequency range that lies in CENELEC-A band of NB-PLC is also proposed. The proposed model is more simple than previously presented models in the literature and has the capability to evaluate the transformers working not only under normal condition but also under resonance condition for frequency of interest. Moreover, the efficient procedure for field measurements that provides a generalized NB-PLC channel model for low voltage access network to deploy AMI within Lahore, Pakistan, is presented. A Simulink model is developed to validate the results. The analysis of measured and simulated results illustrates a close agreement of channel transfer functions. This research work proposes an improved and more accurate NB-PLC channel model especially for South Asian countries.

[1]  Weilin Liu,et al.  Narrow band power line channel characteristics for low voltage access network in China , 2013, 2013 IEEE 17th International Symposium on Power Line Communications and Its Applications.

[2]  A. Cataliotti,et al.  Power-Line Communication in Medium-Voltage System: Simulation Model and Onfield Experimental Tests , 2012, IEEE Transactions on Power Delivery.

[3]  Wonsoo Kim,et al.  Channel measurements and field tests of narrowband power line communication over Korean underground LV power lines , 2014, 18th IEEE International Symposium on Power Line Communications and Its Applications.

[4]  Andrea M. Tonello,et al.  New Results on Top-down and Bottom-up Statistical PLC Channel Modeling , 2009 .

[5]  Sobia Baig,et al.  Opportunities and Challenges of ICT in AMI , 2013 .

[6]  Nikoleta Andreadou,et al.  Telecommunication Technologies for Smart Grid Projects with Focus on Smart Metering Applications , 2016 .

[7]  N. Idir,et al.  High Frequency MV/LV transformer modelling for Power Line Communication applications , 2014, 18th IEEE International Symposium on Power Line Communications and Its Applications.

[8]  Yilmaz Sozer,et al.  Power-Line Impedance Estimation at FCC Band Based on Intelligent Home Appliances Status Detection Algorithm Through Their Individual Energy and Impedance Signatures , 2014, IEEE Transactions on Power Delivery.

[9]  A. Haidine,et al.  Deployment of power line communication by European utilities in advanced metering infrastructure , 2013, 2013 IEEE 17th International Symposium on Power Line Communications and Its Applications.

[10]  Klaus Dostert,et al.  A multipath model for the powerline channel , 2002, IEEE Trans. Commun..

[11]  A M Tonello,et al.  Bottom-Up Statistical PLC Channel Modeling—Part I: Random Topology Model and Efficient Transfer Function Computation , 2011, IEEE Transactions on Power Delivery.

[12]  Jianhui Wang,et al.  Smart Transmission Grid: Vision and Framework , 2010, IEEE Transactions on Smart Grid.

[13]  T. Tran-Quoc,et al.  High frequency power transformer modeling for Power Line Communication applications , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[14]  Nadeem Javaid,et al.  Pakistan's overall energy potential assessment, comparison of LNG, TAPI and IPI gas projects , 2014 .

[15]  T. Banwell,et al.  A novel approach to the modeling of the indoor power line channel-Part II: transfer function and its properties , 2005, IEEE Transactions on Power Delivery.

[16]  Taskin Koçak,et al.  Smart Grid Technologies: Communication Technologies and Standards , 2011, IEEE Transactions on Industrial Informatics.

[17]  John Newbury,et al.  Power line communications : theory and applications for narrowband and broadband communications over power lines , 2010 .

[18]  Andrea M. Tonello,et al.  Measurement and Characterization of Load Impedances in Home Power Line Grids , 2014, IEEE Transactions on Instrumentation and Measurement.

[19]  A. Cataliotti,et al.  Simulation and Laboratory Experimental Tests of a Line to Shield Medium-Voltage Power-Line Communication System , 2011, IEEE Transactions on Power Delivery.

[20]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[21]  N. Theethayi,et al.  Power-Line Communication Channel Model for Interconnected Networks—Part II: Multiconductor System , 2009, IEEE Transactions on Power Delivery.

[22]  Sobia Baig,et al.  Role of Narrow-Band Low Data Rate Power Line Communication in Smart Grids and Noise Reduction Strategy , 2013 .

[23]  A M Tonello,et al.  Bottom-Up Statistical PLC Channel Modeling—Part II: Inferring the Statistics , 2010, IEEE Transactions on Power Delivery.

[24]  Sobia Baig,et al.  Channel modeling of NB-PLC for Smart Grid , 2015, 2015 IEEE Symposium on Computers and Communication (ISCC).

[25]  Antonio Cataliotti,et al.  Measurement Issues for the Characterization of Medium Voltage Grids Communications , 2013, IEEE Transactions on Instrumentation and Measurement.

[26]  S. Galli,et al.  A novel approach to the modeling of the indoor power line channel part I: circuit analysis and companion model , 2005, IEEE Transactions on Power Delivery.

[27]  Tae-Eung Sung,et al.  Time-varying power line block transmission models over doubly selective channels , 2008, 2008 IEEE International Symposium on Power Line Communications and Its Applications.

[28]  Andrea M. Tonello,et al.  Power Line Communications: Understanding the Channel for Physical Layer Evolution Based on Filter Bank Modulation , 2014, IEICE Trans. Commun..

[29]  Klaus Dostert,et al.  On the impedance of the low-voltage distribution grid at frequencies up to 500 kHz , 2012, 2012 IEEE International Symposium on Power Line Communications and Its Applications.

[30]  Stefano Galli,et al.  Next generation Narrowband (under 500 kHz) Power Line Communications (PLC) standards , 2015, China Communications.

[31]  Luís Díez del Río,et al.  A channel model proposal for indoor power line communications , 2011, IEEE Communications Magazine.

[32]  Antonio Cataliotti,et al.  Oil-Filled MV/LV Power-Transformer Behavior in Narrow-Band Power-Line Communication Systems , 2012, IEEE Transactions on Instrumentation and Measurement.

[33]  K. Dostert,et al.  Characteristics of Indoor Power Line Channels in the Frequency Range 50 - 500 kHz , 2006, 2006 IEEE International Symposium on Power Line Communications and Its Applications.

[34]  N. Theethayi,et al.  Power-Line Communication Channel Model for Interconnected Networks—Part I: Two-Conductor System , 2009, IEEE Transactions on Power Delivery.

[35]  T. Noda,et al.  Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies , 2002, IEEE Power Engineering Review.