Lateral Flow Assay Based on Paper–Hydrogel Hybrid Material for Sensitive Point‐of‐Care Detection of Dengue Virus

Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications.

[1]  Mariana Medina-Sánchez,et al.  Simple paper architecture modifications lead to enhanced sensitivity in nanoparticle based lateral flow immunoassays. , 2013, Lab on a chip.

[2]  Daniel T Kamei,et al.  Simultaneous concentration and detection of biomarkers on paper. , 2014, Lab on a chip.

[3]  M. Dou,et al.  A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis , 2014, Analytical chemistry.

[4]  L. Kaiser,et al.  Simultaneous outbreaks of dengue, chikungunya and Zika virus infections: diagnosis challenge in a returning traveller with nonspecific febrile illness , 2016, New microbes and new infections.

[5]  Feng Xu,et al.  Low-cost bioanalysis on paper-based and its hybrid microfluidic platforms. , 2015, Talanta.

[6]  Lixiang Sun,et al.  RILP interacts with HOPS complex via VPS41 subunit to regulate endocytic trafficking , 2014, Scientific reports.

[7]  Il-Hoon Cho,et al.  Ultrasensitive detection of microbial cells using magnetic focus enhanced lateral flow sensors. , 2016, Chemical communications.

[8]  Kinam Park,et al.  Environment-sensitive hydrogels for drug delivery , 2001 .

[9]  Ali Kemal Yetisen,et al.  Paper-based microfluidic point-of-care diagnostic devices. , 2013, Lab on a chip.

[10]  Jie Hu,et al.  Improved sensitivity of lateral flow assay using paper-based sample concentration technique. , 2016, Talanta.

[11]  Jie Hu,et al.  Sensitive biomolecule detection in lateral flow assay with a portable temperature-humidity control device. , 2016, Biosensors & bioelectronics.

[12]  Mingming Yang,et al.  A bare-eye based one-step signal amplified semiquantitative immunochromatographic assay for the detection of imidacloprid in Chinese cabbage samples. , 2015, Analytica chimica acta.

[13]  Da-Jeng Yao,et al.  Molecular-level dengue fever diagnostic devices made out of paper. , 2013, Lab on a chip.

[14]  Paul Yager,et al.  Tunable-delay shunts for paper microfluidic devices. , 2013, Analytical chemistry.

[15]  N. Arunrut,et al.  Rapid and sensitive detection of infectious hypodermal and hematopoietic necrosis virus by loop-mediated isothermal amplification combined with a lateral flow dipstick. , 2011, Journal of virological methods.

[16]  Tzong-Zeng Wu,et al.  Piezoelectric immunochip for the detection of dengue fever in viremia phase. , 2005, Biosensors & bioelectronics.

[17]  Jesse V Jokerst,et al.  Location of biomarkers and reagents within agarose beads of a programmable bio-nano-chip. , 2011, Small.

[18]  Jie Hu,et al.  A volumetric meter chip for point-of-care quantitative detection of bovine catalase for food safety control. , 2016, Analytica chimica acta.

[19]  Mounir Maaloum,et al.  Pore size of agarose gels by atomic force microscopy , 1997, Electrophoresis.

[20]  Feng Xu,et al.  Paper-based sample-to-answer molecular diagnostic platform for point-of-care diagnostics. , 2015, Biosensors & bioelectronics.

[21]  Simon I Hay,et al.  The global burden of dengue: an analysis from the Global Burden of Disease Study 2013. , 2016, The Lancet. Infectious diseases.

[22]  B. Zambrano,et al.  Epidemiology of Dengue in Latin America. , 2014, Journal of the Pediatric Infectious Diseases Society.

[23]  Xiaojun Feng,et al.  Agarose-based microfluidic device for point-of-care concentration and detection of pathogen. , 2014, Analytical chemistry.

[24]  Jonathan D Posner,et al.  Two orders of magnitude improvement in detection limit of lateral flow assays using isotachophoresis. , 2014, Analytical chemistry.

[25]  Jie Hu,et al.  Paper-based point-of-care testing for diagnosis of dengue infections , 2017, Critical reviews in biotechnology.

[26]  Katja Fink,et al.  Electrochemical impedance spectroscopy characterization of nanoporous alumina dengue virus biosensor. , 2012, Bioelectrochemistry.

[27]  Dipankar Bandyopadhyay,et al.  Magnetically guided chemical locomotion of self-propelling paperbots , 2015 .

[28]  徐峰,et al.  即时检测试纸内渗流理论及流动控制研究进展 State-of-Art Advances in Liquid Penetration Theory and Flow Control in Paper for Paper-Based Diagnosis , 2015 .

[29]  Feng Xu,et al.  Advances in paper-based sample pretreatment for point-of-care testing , 2017, Critical reviews in biotechnology.

[30]  Alfredo de la Escosura-Muñiz,et al.  Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes. , 2013, Biosensors & bioelectronics.

[31]  María F. Laguna,et al.  Optimization of Dengue Immunoassay by Label-Free Interferometric Optical Detection Method , 2014, Sensors.

[32]  Jie Hu,et al.  An integrated lateral flow assay for effective DNA amplification and detection at the point of care. , 2016, The Analyst.

[33]  Fei Li,et al.  Advances in paper-based point-of-care diagnostics. , 2014, Biosensors & bioelectronics.

[34]  Hui Xu,et al.  Ultrasensitive nucleic acid biosensor based on enzyme-gold nanoparticle dual label and lateral flow strip biosensor. , 2011, Biosensors & bioelectronics.

[35]  Kim-Kee Tan,et al.  Detection of dengue viruses using reverse transcription-loop-mediated isothermal amplification , 2013, BMC Infectious Diseases.

[36]  Rosanna W. Peeling,et al.  Dengue: a continuing global threat , 2010, Nature Reviews Microbiology.

[37]  Daniela Munteanu,et al.  Correlation between inflammatory biomarkers and metabolic disorders in HIV infected patients undergoing antiretroviral therapy , 2013, BMC Infectious Diseases.

[38]  Zhen Gu,et al.  Detection of mercury ion by infrared fluorescent protein and its hydrogel-based paper assay. , 2011, Analytical chemistry.

[39]  Dipankar Bandyopadhyay,et al.  Paper-based α-amylase detector for point-of-care diagnostics. , 2016, Biosensors & bioelectronics.

[40]  W. Kiatpathomchai,et al.  Rapid and sensitive detection of white spot syndrome virus by loop-mediated isothermal amplification combined with a lateral flow dipstick. , 2009, Molecular and cellular probes.

[41]  Sándor Belák,et al.  Development of a loop-mediated isothermal amplification assay combined with a lateral flow dipstick for rapid and simple detection of classical swine fever virus in the field. , 2014, Journal of virological methods.

[42]  M. Medina‐Sánchez,et al.  Improving sensitivity of gold nanoparticle-based lateral flow assays by using wax-printed pillars as delay barriers of microfluidics. , 2014, Lab on a chip.

[43]  Kim-Kee Tan,et al.  Early Detection of Dengue Virus by Use of Reverse Transcription-Recombinase Polymerase Amplification , 2015, Journal of Clinical Microbiology.

[44]  Daohong Zhang,et al.  Development of a detector-free semiquantitative immunochromatographic assay with major aflatoxins as target analytes , 2013 .

[45]  C. Alpuche-Aranda,et al.  Determination of viremia and concentration of circulating nonstructural protein 1 in patients infected with dengue virus in Mexico. , 2013, The American journal of tropical medicine and hygiene.

[46]  Yi Zhang,et al.  A stacking flow immunoassay for the detection of dengue-specific immunoglobulins in salivary fluid. , 2015, Lab on a chip.