Dithizone Modified Gold Nanoparticles Films as Solid Contact for Cu2+ Ion‐Selective Electrodes

Gold nanoparticles surface modified with dithizone were applied as dedicated transducer in ion-selective electrodes. The presence of a dithizone modified gold nanoparticle layer beneath the ion-selective membrane enables tailoring of copper ion fluxes in all-solid-state copper selective potentiometric electrodes. Thus, depending on the pretreatment of the modified gold nanoparticle layer, different potentiometric responses can be obtained: from typical for systems with lowered activity of primary ions at the back side of the membrane (with super-Nernstian slope region), through low detection limit to classical ones.

[1]  Z. Galus Fundamentals of electrochemical analysis , 1976 .

[2]  Satsuo Kamata,et al.  Copper(II)-selective membrane electrodes based on o-xylylene bis(dithiocarbamates) as neutral carriers , 1989 .

[3]  R. Paradkar,et al.  Micellar Colorimetric Determination of Dithizone Metal Chelates , 1994 .

[4]  J. Bobacka,et al.  Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. , 1999, Analytical chemistry.

[5]  R. Murray,et al.  Monolayer-protected cluster molecules. , 2000, Accounts of chemical research.

[6]  A. Michalska,et al.  All-plastic, disposable, low detection limit ion-selective electrodes , 2004 .

[7]  A. Michalska,et al.  Highly Selective All-Plastic, Disposable, Cu2+-Selective Electrodes , 2005 .

[8]  A. Michalska,et al.  Accumulation of Cu(II) cations in poly(3,4-ethylenedioxythiophene) films doped by hexacyanoferrate anions and its application in Cu2+-selective electrodes with PVC based membranes , 2006 .

[9]  A. Michalska,et al.  Effect of interferents present in the internal solution or in the conducting polymer transducer on the responses of ion-selective electrodes , 2006, Analytical and bioanalytical chemistry.

[10]  Potassium-selective electrodes with stable and geometrically well-defined internal solid contact based on nanoparticles of polyaniline and plasticized poly(vinyl chloride). , 2007, Analytical chemistry.

[11]  A. Stein,et al.  Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact. , 2007, Analytical chemistry.

[12]  F. Rius,et al.  Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers. , 2008, Analytical chemistry.

[13]  M. Fouskaki,et al.  Fullerene-based electrochemical buffer layer for ion-selective electrodes. , 2008, The Analyst.

[14]  Ewa Gorecka,et al.  Liquid-crystalline phases made of gold nanoparticles. , 2009, Angewandte Chemie.

[15]  J. Riu,et al.  Ion-selective electrodes using multi-walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate. , 2009, In Analysis.

[16]  D. Beattie,et al.  Functionalized gold nanoparticles: synthesis, structure and colloid stability. , 2009, Journal of colloid and interface science.

[17]  F. Rius,et al.  Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes. , 2009, Analytical chemistry.

[18]  R. E. Gyurcsányi,et al.  Ionophore-gold nanoparticle conjugates for Ag(+)-selective sensors with nanomolar detection limit. , 2010, Chemical communications.

[19]  Maciej Mazur,et al.  Polypyrrole microcapsules as a transducer for ion-selective electrodes , 2010 .

[20]  Potentiometric online detection of aromatic hydrocarbons in aqueous phase using carbon nanotube-based sensors. , 2010, Analytical chemistry.

[21]  J. Riu,et al.  Real-time potentiometric detection of bacteria in complex samples. , 2010, Analytical chemistry.

[22]  Ewa Gorecka,et al.  Multidimensional structures made by gold nanoparticles with shape-adaptive grafting layers , 2010 .

[23]  E. Jaworska,et al.  Lowering the resistivity of polyacrylate ion-selective membranes by platinum nanoparticles addition. , 2011, Analytical chemistry.

[24]  F. Rius,et al.  An effective nanostructured assembly for ion-selective electrodes. An ionophore covalently linked to carbon nanotubes for Pb2+ determination. , 2011, Chemical communications.

[25]  J. Riu,et al.  Nanostructured materials in potentiometry , 2011, Analytical and bioanalytical chemistry.

[26]  R. E. Gyurcsányi,et al.  Solid-state ion channels for potentiometric sensing. , 2011, Angewandte Chemie.

[27]  J. Riu,et al.  Potentiometric strip cell based on carbon nanotubes as transducer layer: toward low-cost decentralized measurements. , 2011, Analytical chemistry.

[28]  E. Jaworska,et al.  Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings. , 2011, Talanta.

[29]  E. Jaworska,et al.  Non-covalently functionalized graphene for the potentiometric sensing of zinc ions. , 2012, The Analyst.

[30]  Jakub Szlachetko,et al.  Photopolymerized polypyrrole microvessels. , 2012, Chemistry.

[31]  E. Jaworska,et al.  Critical assessment of graphene as ion-to-electron transducer for all-solid-state potentiometric sensors. , 2012, Talanta.

[32]  M. Wójcik,et al.  Dithizone modified gold nanoparticles films for potentiometric sensing. , 2012, Analytical chemistry.

[33]  A. Michalska All‐Solid‐State Ion Selective and All‐Solid‐State Reference Electrodes , 2012 .

[34]  Fenghua Li,et al.  All-solid-state potassium-selective electrode using graphene as the solid contact. , 2012, The Analyst.

[35]  A. Kisiel,et al.  Microspheres aided introduction of ionophore and ion-exchanger to the ion-selective membrane. , 2012, Talanta.