Comparison of the corrosion of fasteners embedded in wood measured in outdoor exposure with the predictions from a combined hygrothermal-corrosion model

Abstract This paper examines the accuracy of a recently developed hygrothermal-corrosion model which predicts the corrosion of fasteners embedded in wood by comparing the results of the model to a one year field test. Steel and galvanized steel fasteners were embedded into untreated and preservative treated wood and exposed outdoors while weather data were collected. Qualitatively, the distribution of corrosion products along the length of the fastener were in agreement with the simulation results. Quantitatively, the combined hygrothermal-corrosion model predicted 20% less corrosion than measured in the exposure test for galvanized steel fasteners due to a lower simulated moisture content.

[1]  D. Rammer,et al.  Synthesis of published and unpublished corrosion data from long term tests of fasteners embedded in wood : calculation of corrosion rates and the effect of corrosion on lateral joint strength , 2011 .

[2]  G. Droguett,et al.  Comparison of steel anticorrosive protection formulated with natural tannins extracted from acacia and from pine bark , 2000 .

[3]  B. Hicks,et al.  The NOAA Integrated Surface Irradiance Study (ISIS) - A new surface radiation monitoring program , 1996 .

[4]  Analytical Determination of the Surface Area of a Threaded Fastener , 2008 .

[5]  J. K. Dennis,et al.  Corrosion Resistance of Zinc-alloy Coated Steel in Construction Industry Environments , 1997 .

[6]  G. Kear,et al.  Corrosion of ferrous- and zinc-based materials in CCA, ACQ and CuAz timber preservative aqueous solutions , 2008 .

[7]  J. Gust,et al.  Sealing and anti-corrosive action of tannin rust converters , 1993 .

[8]  F. Walsh,et al.  Impedance spectroscopy studies of the dissolution of ferrous- and zinc-based materials in aqueous timber preservatives , 2008 .

[9]  Preet M. Singh,et al.  Role of Wood Extractives in Black Liquor Corrosiveness , 2006 .

[10]  J. K. Dennis,et al.  Corrosion behaviour of zinc and zinc alloy coated steel in preservative treated timber , 1995 .

[11]  A. Scalbert,et al.  Precipitation of metal ions by plant polyphenols: optimal conditions and origin of precipitation , 1996 .

[12]  Dominique Derome,et al.  The effect of moisture content on the corrosion of fasteners embedded in wood subjected to alkaline copper quaternary treatment , 2014 .

[13]  E. Rocca,et al.  Inhibitive action of mangrove tannins and phosphoric acid on pre-rusted steel via electrochemical methods , 2008 .

[14]  Samuel L. Zelinka,et al.  Uncertainties in Corrosion Rate Measurements of Fasteners Exposed to Treated Wood at 100 % Relative Humidity , 2007 .

[15]  Douglas R. Rammer,et al.  Corrosion Rates of Fasteners in Treated Wood Exposed to 100% Relative Humidity , 2009 .

[16]  R. Legault,et al.  Kinetics of the Atmospheric Corrosion of Galvanized Steel , 1978 .

[17]  Jan Carmeliet,et al.  CONSERVATIVE MODELLING OF THE MOISTURE AND HEAT TRANSFER IN BUILDING COMPONENTS UNDER ATMOSPHERIC EXCITATION , 2007 .

[18]  Dominique Derome,et al.  Combining hygrothermal and corrosion models to predict corrosion of metal fasteners embedded in wood , 2011 .

[19]  F. Walsh,et al.  Direct-Current Methods for the Estimation of Corrosion Rates in Aqueous Timber Preservatives , 2008 .

[20]  D. Stone,et al.  The effect of tannins and pH on the corrosion of steel in wood extracts , 2011 .

[21]  C. Gervasi,et al.  Corrosion inhibition of mild steel in HCL solution by pectin , 2015 .

[22]  R. A. Legault,et al.  Kinetics of the Atmospheric Corrosion of Low-Alloy Steels in an Industrial Environment , 1975 .

[23]  M. Azzi,et al.  Effect of vegetal tannin on anodic copper dissolution in chloride solutions , 2004 .

[24]  D. Stone,et al.  Corrosion of metals in wood: Comparing the results of a rapid test method with long-term exposure tests across six wood treatments , 2011 .

[25]  Donald S. Stone,et al.  Exposure testing of fasteners in preservative treated wood: Gravimetric corrosion rates and corrosion product analyses , 2010 .

[26]  G. Kear,et al.  Weight loss studies of fastener materials corrosion in contact with timbers treated with copper azole and alkaline copper quaternary compounds , 2009 .

[27]  Wolfgang Zillig,et al.  Moisture Transport in Wood Using a Multiscale Approach (Vocht transport in hout op basis van een multischaal benadering) , 2009 .

[28]  A. Baker,et al.  Corrosion of nails in CCA- and ACA-treated wood in two environments , 1992 .

[29]  H. Danninger,et al.  Corrosion mechanisms in the wood industry, especially caused by tannins , 2009 .

[30]  Kevin W Eliceiri,et al.  NIH Image to ImageJ: 25 years of image analysis , 2012, Nature Methods.

[31]  S. Zelinka Comparing the Methodologies in ASTM G198: Is There an Easy Way Out? , 2013 .

[32]  Samuel V. Glass,et al.  Moisture relations and physical properties of wood , 2010 .

[33]  D. R. Rammer,et al.  Optical method for measuring the surface area of a threaded fastener , 2009 .

[34]  Dominique Derome,et al.  Moisture storage and transport properties of preservative treated and untreated southern pine wood , 2016 .

[35]  Jenna Jambeck,et al.  Preservative Treated Wood , 2010 .

[36]  Douglas R. Rammer,et al.  Electrochemical corrosion testing of fasteners in extracts of treated wood , 2008 .

[37]  Mayanker Singh,et al.  Corrosion inhibition of mild steel in acidic solution by Tagetes erecta (Marigold flower) extract as a green inhibitor , 2014 .

[38]  D. Rammer,et al.  Modeling the Effect of Nail Corrosion on the Lateral Strength of Joints , 2012 .