Effect of cornea material stiffness on measured intraocular pressure.

Intraocular pressure (IOP) in the human eye as measured by a Goldmann applanation tonometer (GAT) is known to be affected by individual differences in central corneal thickness (CCT). However, data from clinical studies also show considerable scatter in the correlation between measured IOP and CCT. One possible implication of the large observed scatter is that the true IOP (IOPT) also depends significantly on individual variations in the material stiffness properties of the cornea. This hypothesis is explored and evaluated herein using computational simulation of applanation tonometry. A simplified 2D finite element model of the eye, which employs a calibrated nonlinear transversely isotropic material model for the cornea, is developed, and a series of GAT simulations is carried out to study the effect of geometry and material properties of the cornea on the IOP readings obtained via GAT. The results of this parametric study provide a simple correction equation, which quantifies the effect on measured IOP of variations in CCT and corneal material stiffness. In addition, several previously proposed IOP correction equations are compared with the one proposed here.

[1]  R A Moses,et al.  Increased corneal thickness simulating elevated intraocular pressure. , 1978, Archives of ophthalmology.

[2]  N A Brennan,et al.  Anatomically accurate, finite model eye for optical modeling. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  R. Stein,et al.  The effect of corneal thickness on applanation tonometry. , 1993, American journal of ophthalmology.

[4]  Y. Fung,et al.  Pseudoelasticity of arteries and the choice of its mathematical expression. , 1979, The American journal of physiology.

[5]  M. R. Bryant,et al.  Constitutive laws for biomechanical modeling of refractive surgery. , 1996, Journal of biomechanical engineering.

[6]  T. Kwon Minimally Invasive Characterization and Intraocular Pressure Measurement via Numerical Simulation of Human Cornea , 2006 .

[7]  R. Krueger,et al.  How might corneal elasticity help us understand diabetes and intraocular pressure? , 2007, Journal of refractive surgery.

[8]  Sunil Shah,et al.  Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. , 2002, Investigative ophthalmology & visual science.

[9]  N. Ehlers,et al.  APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS , 1975, Acta ophthalmologica.

[10]  R. S. Mackay,et al.  A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of intraocular pressure , 1966 .

[11]  D. Pye,et al.  Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo , 1999, Bulletin of mathematical biology.

[12]  J. Stahl,et al.  Effect of corneal thickness on the accuracy of intraocular pressure measurement in rabbits after excimer laser photoablation. , 2000, Journal of cataract and refractive surgery.