Effect of Improper Scan Alignment on Retinal Nerve Fiber Layer Thickness Measurements Using Stratus Optical Coherence Tomograph

ObjectiveMisalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. DesignObservational clinical study. MethodsSixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered on the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. ResultsWhen the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 μm), superiorly (106.2 μm), or inferiorly (104.1 μm) displaced scans and the centered scans (106.4 μm). However, a significant difference (analysis of variance with Dunnett's test: F=8.82, P<0.0001) was found between temporally displaced scans (115.8 μm) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. ConclusionsIn normal eyes, average RNFL thickness measurements are robust and similar with significant superior, inferior, and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.

[1]  Mei-Ling Huang,et al.  Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[2]  Ki Ho Park,et al.  Diagnostic ability of optical coherence tomography with a normative database to detect localized retinal nerve fiber layer defects. , 2005, Ophthalmology.

[3]  Robert N Weinreb,et al.  Combining structural and functional testing for detection of glaucoma. , 2006, Ophthalmology.

[4]  Christopher Bowd,et al.  Retinal nerve fiber layer analysis in the diagnosis of glaucoma. , 2006, Current opinion in ophthalmology.

[5]  R. Bourne,et al.  Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry. , 2006, Investigative ophthalmology & visual science.

[6]  E A Swanson,et al.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. , 1995, Archives of ophthalmology.

[7]  G. Savini,et al.  Influence of Pupil Size and Cataract on Retinal Nerve Fiber Layer Thickness Measurements by Stratus OCT , 2006, Journal of glaucoma.

[8]  J. Katz,et al.  Sensitivity and specificity of the StratusOCT for perimetric glaucoma. , 2005, Ophthalmology.

[9]  D. Greenfield,et al.  Quantitative assessment of structural damage in eyes with localized visual field abnormalities. , 2004, American journal of ophthalmology.

[10]  R. Bourne,et al.  Relationship between patterns of visual field loss and retinal nerve fiber layer thickness measurements. , 2006, American journal of ophthalmology.

[11]  P. Carpineto,et al.  Custom Measurement of Retinal Nerve Fiber Layer Thickness Using STRATUS OCT in Normal Eyes , 2005, European journal of ophthalmology.

[12]  G. Wollstein,et al.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. , 2004, Investigative ophthalmology & visual science.

[13]  F. Medeiros,et al.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. , 2005, American journal of ophthalmology.

[14]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[15]  M. L. Salvetat,et al.  Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma. , 2006, Acta ophthalmologica Scandinavica.

[16]  F. Medeiros,et al.  Optic Nerve Imaging: Recent Advances , 2004 .

[17]  F. Medeiros,et al.  Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. , 2004, Archives of ophthalmology.

[18]  Optical coherence tomography for clinical detection and monitoring of glaucoma? , 2007, British Journal of Ophthalmology.

[19]  Parul Sony,et al.  Diagnostic capability of optical coherence tomography in evaluating the degree of glaucomatous retinal nerve fiber damage. , 2006, Investigative ophthalmology & visual science.

[20]  F. Medeiros,et al.  Differences in visual function and optic nerve structure between healthy eyes of blacks and whites. , 2005, Archives of ophthalmology.

[21]  M. Shahidi,et al.  Thickness of the peripapillary retina in healthy subjects with different degrees of ametropia. , 2000, Ophthalmology.

[22]  R. Knighton,et al.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. , 2005, Investigative ophthalmology & visual science.