Simulation of dynamics-coupling in piezoelectric tube scanners by reduced order finite element analysis.

Piezoelectric tube scanners are widely used in scanning probe microscopes to position the sample or the probe. Fast and accurate scanning requires the suppression of dominant low-frequency resonances as well as the compensation of dynamics-coupling effects. The present article gives a detailed description of the fully coupled tube scanner dynamics over a wide frequency range modeled by finite element (FE) analysis using the commercially available software package ANSYS. The effect of a sample mass attached to the top of the tube is investigated by considering its added mass and local stiffening. A model order reduction scheme is applied to obtain a low order model that describes the lateral and vertical deflections as well as the voltage induced on quadrant electrodes. Comparison to experimental data demonstrates a good agreement for both the full FE model and reduced order model.

[1]  Lothar Gaul,et al.  Finite element-based analysis of shunted piezoelectric structures for vibration damping , 2006 .

[2]  Qiao Sun,et al.  Three-dimensional displacement analysis of a piezoelectric tube scanner through finite element simulations of a tube assembly , 2006 .

[3]  J. Garbini,et al.  The design and control of a three-dimensional piezoceramic tube scanner with an inertial slider , 2006 .

[4]  S. O. Reza Moheimani,et al.  Sensor-less Vibration Suppression and Scan Compensation for Piezoelectric Tube Nanopositioners , 2005, Proceedings of the 44th IEEE Conference on Decision and Control.

[5]  Qingze Zou,et al.  Iterative control of dynamics-coupling-caused errors in piezoscanners during high-speed AFM operation , 2005, IEEE Transactions on Control Systems Technology.

[6]  J.A. De Abreu-Garcia,et al.  Tracking control of a piezoceramic actuator with hysteresis compensation using inverse Preisach model , 2005, IEEE/ASME Transactions on Mechatronics.

[7]  Wodek Gawronski,et al.  Advanced Structural Dynamics and Active Control of Structures , 2004 .

[8]  Young-Hun Lim Finite-element simulation of closed loop vibration control of a smart plate under transient loading , 2003 .

[9]  Meng-Shiun Tsai,et al.  Robust Tracking Control of a Piezoactuator Using a New Approximate Hysteresis Model , 2003 .

[10]  F. Allgöwer,et al.  A new control strategy for high-speed atomic force microscopy , 2003 .

[11]  Murti V. Salapaka,et al.  High bandwidth nano-positioner: A robust control approach , 2002 .

[12]  A. Preumont,et al.  Finite element modelling of piezoelectric active structures , 2001 .

[13]  D. Croft,et al.  Creep, hysteresis, and vibration compensation for piezoactuators: atomic force microscopy application , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[14]  V. Piefort FINITE ELEMENT MODELING OF PIEZOELECTRIC STRUCTURES , 2000 .

[15]  Roger Ohayon,et al.  A Unified Beam Finite Element Model for Extension and Shear Piezoelectric Actuation Mechanisms , 1997 .

[16]  A. Preumont Vibration Control of Active Structures , 1997 .

[17]  R. Carr,et al.  Finite element analysis of PZT tube scanner motion for scanning tunnelling microscopy , 1988 .

[18]  G. Binnig,et al.  Single-tube three-dimensional scanner for scanning tunneling microscopy , 1986 .

[19]  John F. MacGregor,et al.  Proceedings of the American Control Conference , 1985 .