Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device

Even if still at an early stage of development, non-invasive continuous glucose monitoring (NI-CGM) sensors represent a promising technology for optimizing diabetes therapy. Recent studies showed that the Multisensor provides useful information about glucose dynamics with a mean absolute relative difference (MARD) of 35.4% in a fully prospective setting. Here we propose a method that, exploiting the same Multisensor measurements, but in a retrospective setting, achieves a much better accuracy. Data acquired by the Multisensor during a long-term study are retrospectively processed following a two-step procedure. First, the raw data are transformed to a blood glucose (BG) estimate by a multiple linear regression model. Then, an enhancing module is applied in cascade to the regression model to improve the accuracy of the glucose estimation by retrofitting available BG references through a time-varying linear model. MARD between the retrospectively reconstructed BG time-series and reference values is 20%. Here, 94% of values fall in zone A or B of the Clarke Error Grid. The proposed algorithm achieved a level of accuracy that could make this device a potential complementary tool for diabetes management and also for guiding prediabetic or nondiabetic users through life-style changes.

[1]  Giovanni Sparacino,et al.  Regularised Model Identification Improves Accuracy of Multisensor Systems for Noninvasive Continuous Glucose Monitoring in Diabetes Management , 2013, J. Appl. Math..

[2]  Giovanni Sparacino,et al.  Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications , 2018, Journal of diabetes science and technology.

[3]  I M E Wentholt,et al.  How to assess and compare the accuracy of continuous glucose monitors? , 2008, Diabetes technology & therapeutics.

[4]  Mattia Zanon,et al.  The Effect of a Global, Subject, and Device-Specific Model on a Noninvasive Glucose Monitoring Multisensor System , 2015, Journal of diabetes science and technology.

[5]  Rishikesh Pandey,et al.  Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy. , 2017, Accounts of chemical research.

[6]  Tracey Neithercott Continuous glucose monitors. , 2011, Diabetes forecast.

[7]  Joseph P Shivers,et al.  Continuous glucose monitors: current status and future developments , 2013, Current opinion in endocrinology, diabetes, and obesity.

[8]  G. Mcgarraugh The chemistry of commercial continuous glucose monitors. , 2009, Diabetes technology & therapeutics.

[9]  W. Clarke The original Clarke Error Grid Analysis (EGA). , 2005, Diabetes technology & therapeutics.

[10]  Pavel Zakharov,et al.  Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation. , 2011, Biosensors & bioelectronics.

[11]  Santhisagar Vaddiraju,et al.  Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises , 2010, Journal of diabetes science and technology.

[12]  Zhigang Zhu,et al.  Current and Emerging Technology for Continuous Glucose Monitoring , 2017, Sensors.

[13]  Giovanni Sparacino,et al.  Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system , 2012, Medical & Biological Engineering & Computing.

[14]  A. Caduff,et al.  The effect of blood content on the optical and dielectric skin properties , 2011, Physiological measurement.

[15]  Silvia Santini,et al.  Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis , 2019, PervasiveHealth.

[16]  G. W. Small,et al.  Noninvasive glucose sensing. , 2005, Analytical chemistry.

[17]  Bernhard Wolf,et al.  Multiparameter techniques for non-invasive measurement of blood glucose , 2009 .

[18]  Pavel Zakharov,et al.  Cutaneous blood perfusion as a perturbing factor for noninvasive glucose monitoring. , 2010, Diabetes technology & therapeutics.

[19]  Mark J. Buller,et al.  The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers , 2018 .

[20]  David Rodbard,et al.  Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities. , 2016, Diabetes technology & therapeutics.

[21]  Thomas Klotzbuecher,et al.  In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring. , 2014, Biosensors & bioelectronics.

[22]  I. Harman-boehm,et al.  Noninvasive Glucose Monitoring: Increasing Accuracy by Combination of Multi-Technology and Multi-Sensors , 2010, Journal of diabetes science and technology.

[23]  A. Caduff,et al.  Measurement and simulation of conductive dielectric two-layer materials with a multiple electrodes sensor , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  Mattia Zanon,et al.  First Experiences With a Wearable Multisensor in an Outpatient Glucose Monitoring Study, Part I: The Users’ View , 2018, Journal of diabetes science and technology.

[25]  R. Esenaliev,et al.  Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. , 2002, Diabetes care.

[26]  Mattia Zanon,et al.  First Experiences With a Wearable Multisensor Device in a Noninvasive Continuous Glucose Monitoring Study at Home, Part II: The Investigators’ View , 2018, Journal of diabetes science and technology.

[27]  Liliana Barrios,et al.  Recognizing Digital Biomarkers for Fatigue Assessment in Patients with Multiple Sclerosis , 2018 .

[28]  Giovanni Sparacino,et al.  Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment , 2017 .

[29]  Yu Feldman,et al.  Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy. , 2006, Biosensors & bioelectronics.