Quantitative analysis of left ventricular function from equilibrium gated blood pool scintigrams: an overview of computer methods

An overview is presented on different techniques for data acquisition and analysis of technetium-99m gated blood pool scintigrams. The basic principles for semi- and fully automated boundary detection of the left ventricular activity structure in one or more frames and for the selection of the background region of interest are described. Methods for the computation of global and regional ejection fraction are discussed and comparative data from scintigraphic and contrast left ventricular angiography presented. Finally, an overview of commercially available state of the art computer programs for the computation of global and regional ejection fraction is presented.

[1]  Eric G. Hawman Digital Boundary Detection Techniques For The Analysis Of Gated Cardiac Scintigrams , 1981 .

[2]  M. Pfisterer,et al.  Response of Left Ventricular Volume to Exercise in Man Assessed by Radionuclide Equilibrium Angiography , 1979, Circulation.

[3]  R. Dinsmore,et al.  Observer Variance in the Qualitative Evaluation of Left Ventricular Wall Motion and the Quantitation of Left Ventricular Ejection Fraction Using Rest and Exercise Multigated Blood Pool Imaging , 1980, Circulation.

[4]  M. Nagao,et al.  Edge preserving smoothing , 1979 .

[5]  A. Todd-Pokropek Image Processing in Nuclear Medicine , 1980, IEEE Transactions on Nuclear Science.

[6]  D R Ricci,et al.  Validity of left-ventricular ejection fractions measured at rest and peak exercise by equilibrium radionuclide angiography using short acquisition times. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  J. J. Gerbrands,et al.  Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Michael J. Welch,et al.  Development of a positron emitting radio pharmaceutical suitable for imaging myelin , 1982 .

[9]  S M Larson,et al.  The radionuclide ejection fraction: a comparison of three radionuclide techniques with contrast angiography. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  W R Brody,et al.  Ejection fraction by count rate from gated images. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  M. A. Douglas,et al.  High temporal resolution ECG-gated scintigraphic angiocardiography. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  E Nickoloff,et al.  Analysis of Left Ventricular Function from Multiple Gated Acquisition Cardiac Blood Pool Imaging Comparison to Contrast Angiography , 1977, Circulation.

[13]  Daniel S. Berman,et al.  Validation of a two minute technique for multiple gated scintigraphic assessment of left ventricular ejection fraction and regional wall motion , 1978 .

[14]  L. Smith,et al.  Effect of Filming Projection and Interobserver Variability on Angiographic Biplane Left Ventricular Volume Determination , 1979, Circulation.

[15]  P. R. Bell,et al.  Nonlinear Image Processing Methods , 1978, IEEE Transactions on Nuclear Science.

[16]  G S Johnston,et al.  Sensitivity, Specificity and Predictive Accuracy of Radionuclide Cineangiography During Exercise in Patients with Coronary Artery Disease: Comparison with Exercise Electrocardiography , 1979, Circulation.

[17]  T R Miller,et al.  Digital filtering in nuclear medicine. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  L Goldman,et al.  Multiple gated cardiac blood pool imaging for left ventricular ejection fraction: validation of the technique and assessment of variability. , 1979, The American journal of cardiology.

[19]  J S Borer,et al.  Instrumentation and data processing in cardiovascular nuclear medicine: evaluation of ventricular function. , 1979, Seminars in nuclear medicine.

[20]  J A Parker,et al.  Ejection fraction image: a noninvasive index of regional left ventricular wall motion. , 1978, The American journal of cardiology.

[21]  T. K. Natarajan,et al.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization. , 1971, The American journal of cardiology.

[22]  G. S. Robinson Edge detection by compass gradient masks , 1977 .

[23]  J A Parker,et al.  A new technique for the calculation of left ventricular ejection fraction. , 1972, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  R. Helfant,et al.  Nuclear cardiology. I. Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. , 1980, The American journal of cardiology.

[25]  D. J. Hale,et al.  Methods for detection of left ventricular edges. , 1980, Seminars in nuclear medicine.

[26]  E L Nickoloff,et al.  Temporal resolution requirements for left ventricular time-activity curves. , 1980, Radiology.

[27]  P Richards,et al.  Cardiac chamber imaging: a comparison of red blood cells labeled with Tc-99m in vitro and in vivo. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  B. Chaitman,et al.  Objective and Subjective Analysis of Left Ventricular Angiograms , 1975, Circulation.

[29]  J A Parker,et al.  Radionuclide left ventriculography with the slant hole collimator. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[30]  H R Schelbert,et al.  Left ventricular ejection fraction--a review of several radionuclide angiographic approaches using the scintillation camera. , 1978, Progress in cardiovascular diseases.

[31]  I.E. Abdou,et al.  Quantitative design and evaluation of enhancement/thresholding edge detectors , 1979, Proceedings of the IEEE.

[32]  J L Ritchie,et al.  R-wave synchronized blood-pool imaging. , 1979, Radiology.

[33]  G. B. Hopkins,et al.  Edge enhancement of ECG-gated cardiac images using directional masks. , 1978, Radiology.

[34]  F. Maul,et al.  Fully automated sectorial equilibrium radionuclide ventriculography , 1983, European Journal of Nuclear Medicine.

[35]  Michael V. Green,et al.  Left-ventricular peak ejection rate, filling rate, and ejection fraction--frame rate requirements at rest and exercise: concise communication. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[36]  Martin Stauch,et al.  Radionuklid-Ventrikulographie I. Grundlagen und Methoden , 1978, Nuklearmedizin.

[37]  Larry S. Davis,et al.  A survey of edge detection techniques , 1975 .

[38]  J A Parker,et al.  Regional Ejection Fraction A Quantitative Radionuclide Index of Regional Left Ventricular Performance , 1979, Circulation.

[39]  B A Goddard,et al.  The effect of various background protocols on the measurement of left ventricular ejection fraction in equilibrium radionuclide angiography. , 1980, The British journal of radiology.