Environmental and technical assessments of the potential utilization of sewage sludge ashes (SSAs) as secondary raw materials in construction.

Ashes produced by thermal treatments of sewage sludge exhibit common properties with cement. For example, major elements present in SSA are the same of major elements of cement. Hydraulic properties of SSA are quite the same of cement ones. They may therefore be used to substitute part of cement in concrete or other cementitious materials, provided that technical prescriptions are satisfied and that environmental risks are not significantly increased. The objective of the present study was to determine the appropriate substitution ratios to satisfy both technical and environmental criteria. In a first step, the elemental composition and particle size distribution of the ashes were measured. Then the ashes were used along with Portland cement and sand at different ratios of substitution to produce mortar and concrete which were cured for up to 90 days into parallelepipedic or cylindrical monoliths. The mechanical properties of the monoliths were measured using standard procedures for flexural and compressive strengths, and compared to blanks containing no ashes. The environmental criteria were assessed using leaching tests conducted according to standard protocols both on the ashes and the monoliths, and compared to the blanks. Results showed that the characteristics of the ashes ranged between those of cement and sand because of their larger particle size and higher content in SiO2 as compared to cement. The monoliths made with the highest substitution ratios exhibited a significant decrease in flexural and compressive strengths. However, when the ashes were used in partial substitution of cement at appropriate ratios, the concrete monoliths exhibited similar compressive strengths as the blank samples. The most appropriate ratios were found to be 10% substitution of cement and 2% substitution of sand. The leaching tests conducted on the ashes in their powdery form revealed that amongst the potential contaminants analyzed only Mo and Se were leached at concentrations above the threshold limits considered. The leaching tests conducted on concrete monoliths showed however that none of the contaminants monitored, including Mo and Se, were leached above the limits. In addition, whether concrete recipe incorporated ashes or not, similar concentrations were measured for each potential contaminant in the leachates. This result indicated that mixing ash with cement and sand to produce mortar or concrete induced a stabilization of Mo and Se and thereby constituted in itself a good treatment of the ashes.

[1]  T. Kojima,et al.  Compositions and leaching behaviours of combustion residues , 2006 .

[2]  T Sabbas,et al.  Management of municipal solid waste incineration residues. , 2003, Waste management.

[3]  J. Monzó,et al.  Reuse of sewage sludge ashes (SSA) in cement mixtures: the effect of SSA on the workability of cement mortars. , 2003, Waste management.

[4]  P. K. Mehta,et al.  Concrete: Microstructure, Properties, and Materials , 2005 .

[5]  Michael Tate THE MOST IMPORTANT PROPERTY OF CEMENT-LIME MORTAR IN MASONRY CONSTRUCTION IS …. ∗ , 2005 .

[6]  Bekir Yılmaz Pekmezci,et al.  Optimum usage of a natural pozzolan for the maximum compressive strength of concrete , 2004 .

[7]  Bernd Wiebusch,et al.  Characteristics of heavy metal release from incinerated ash, melted slag and their re-products , 1997 .

[8]  Mark Tyrer,et al.  EU landfill waste acceptance criteria and EU Hazardous Waste Directive compliance testing of incinerated sewage sludge ash. , 2010, Waste management.

[9]  J Baeyens,et al.  The distribution of heavy metals during fluidized bed combustion of sludge (FBSC). , 2008, Journal of hazardous materials.

[10]  L. Petrik,et al.  The use of X-ray fluorescence (XRF) analysis in predicting the alkaline hydrothermal conversion of fly ash precipitates into zeolites. , 2004, Talanta.

[11]  J. Corella,et al.  Incineration of doped sludges in fluidized bed. Fate and partitioning of six targeted heavy metals. I. Pilot plant used and results. , 2000, Journal of hazardous materials.

[12]  J. R. Benson Highly porous polymers , 2003 .

[13]  Z. Rakotoarisoa Prédiction du comportement environnemental des résidus de procédés thermiques (RPT) utilisés comme matériaux de travaux publics , 2003 .

[14]  N Lapa,et al.  The behaviour of ashes and heavy metals during the co-combustion of sewage sludges in a fluidised bed. , 2003, Waste management.

[15]  M. E. Brown,et al.  Introduction to Thermal Analysis: Techniques and applications , 1988 .

[16]  F. Romero,et al.  Characterization and possible uses of ashes from wastewater treatment plants. , 2005, Waste management.

[17]  K. Chiang,et al.  Hydration characteristics of waste sludge ash that is reused in eco-cement clinkers , 2005 .

[18]  B. Kovács,et al.  Speciation of chromium from industrial wastes and incinerated sludges , 1997 .