Suppression of nonlinear optical frequency sweeping in frequency-scanning interferometry for absolute distance measurement

The precision of Frequency-scanning interferometer(FSI) for absolute distance measurement depends much on the tunability of its laser source. However, an external cavity laser diode (ECLD) exhibits nonlinearity during optical frequency sweep due to hysteresis inherent to the piezoelectric ceramic transducer (PZT) actuator in the ECDL. As a result, the interference signal become nonstationary, and then extracting the phase of the nonstationary interference signal may cause errors. To address this problem, we propose a new method based on the Prandtl–Ishlinskii (PI) model for suppressing nonlinearity of optical frequency sweeping. For the proposed FSI, the output transmission signal of a Fabry–Perot (F-P) cavity is used to obtain the optical frequency curve of the ECLD. By using the input voltage of the linear driving signal and the optical frequency of the ECLD as input and output of the model respectively, the hysteresis model can be built based on PI modelling method. Hence, the inverse of the rate-independent PI model is employed as a feedforward controller to compensate the nonlinearity of the optical frequency sweeping. In our case, instead of driving the ECLD with a linear signal, we implement a corrected nonlinear driving signal of the PZT to suppress the nonlinearity of the sweeping frequency. Experimental results demonstrate the effectiveness of our proposed method. Compared with an external witness He–Ne incremental interferometer, the proposed method greatly improves the performance of the FSI for absolute distance measurement.

[1]  Bingguo Liu,et al.  FSI-based non-cooperative target absolute distance measurement method using PLL correction for the influence of a nonlinear clock. , 2018, Optics Letters.

[2]  Matthew S. Warden,et al.  Dual-Sweep Frequency Scanning Interferometry Using Four Wave Mixing , 2015, IEEE Photonics Technology Letters.

[3]  Weiqi Wang,et al.  Precision improvement of frequency-modulated continuous-wave laser ranging system with two auxiliary interferometers , 2018 .

[4]  Bing Li,et al.  Precision improvement in frequency-scanning interferometry based on suppressing nonlinear optical frequency sweeping , 2015, Optical Review.

[5]  Ruili Dong,et al.  A modified Prandtl–Ishlinskii modeling method for hysteresis , 2009 .

[6]  Zhongwen Deng,et al.  Frequency-scanning interferometry using a time-varying Kalman filter for dynamic tracking measurements. , 2017, Optics express.

[7]  Yanding Qin,et al.  Modeling and Identification of the Rate-Dependent Hysteresis of Piezoelectric Actuator Using a Modified Prandtl-Ishlinskii Model , 2017, Micromachines.

[8]  Li-Min Zhu,et al.  Modeling and Compensation of Asymmetric Hysteresis Nonlinearity for Piezoceramic Actuators With a Modified Prandtl–Ishlinskii Model , 2014, IEEE Transactions on Industrial Electronics.

[9]  Yuansheng Chen,et al.  A modified prandtl-ishlinskii model for modeling asymmetric hysteresis of piezoelectric actuators , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  A. Reichold,et al.  Multi-channel absolute distance measurement system with sub ppm-accuracy and 20 m range using frequency scanning interferometry and gas absorption cells. , 2014, Optics express.

[11]  A. Cabral,et al.  Accuracy of frequency-sweeping interferometry for absolute distance metrology , 2007 .

[12]  Xinghua Qu,et al.  Micron-precision measurement using a combined frequency-modulated continuous wave ladar autofocusing system at 60 meters standoff distance. , 2018, Optics express.