Series of experiments for empirical validation of solar gain modeling in building energy simulation codes—Experimental setup, test cell characterization, specifications and uncertainty analysis

Empirical validation of building energy simulation codes is an important component in understanding the capacity and limitations of the software. Within the framework of Task 34/Annex 43 of the International Energy Agency (IEA), a series of experiments was performed in an outdoor test cell. The objective of these experiments was to provide a high-quality data set for code developers and modelers to validate their solar gain models for windows with and without shading devices. A description of the necessary specifications for modeling these experiments is provided in this paper, which includes information about the test site location, experimental setup, geometrical and thermophysical cell properties including estimated uncertainties. Computed overall thermal cell properties were confirmed by conducting a steady-state experiment without solar gains. A transient experiment, also without solar gains, and corresponding simulations from four different building energy simulation codes showed that the provided specifications result in accurate thermal cell modeling. A good foundation for the following experiments with solar gains was therefore accomplished.

[1]  Daniel E. Fisher,et al.  EnergyPlus: creating a new-generation building energy simulation program , 2001 .

[2]  Joseph Andrew Clarke,et al.  Energy Simulation in Building Design , 1985 .

[3]  Kevin J. Lomas,et al.  Sensitivity analysis techniques for building thermal simulation programs , 1992 .

[4]  P. Strachan,et al.  Model validation using the PASSYS Test cells , 1993 .

[5]  Gilles Guyon,et al.  Theoretical basis for empirical model validation using parameters space analysis tools , 2003 .

[6]  Abdullatif Ben-Nakhi,et al.  Development and integration of a user friendly validation module within whole building dynamic simulation , 2003 .

[7]  R. D. Judkoff,et al.  Validation of building energy analysis simulation programs at the solar energy research institute , 1988 .

[8]  Th. Frank,et al.  Thermal simulation of buildings with double-skin façades , 2005 .

[9]  Gilles Guyon,et al.  Application of parameters space analysis tools for empirical model validation , 2004 .

[10]  R. Judkoff,et al.  International Energy Agency building energy simulation test (BESTEST) and diagnostic method , 1995 .

[11]  Paul Strachan,et al.  Practical application of uncertainty analysis , 2001 .

[12]  P. Wouters,et al.  The use of outdoor test cells for thermal and solar building research within the PASSYS project , 1993 .

[13]  Leon Jay Gleser,et al.  Assessing uncertainty in measurement , 1998 .

[14]  Søren Østergaard Jensen,et al.  Validation of building energy simulation programs: a methodology , 1995 .

[15]  Kevin J. Lomas,et al.  Empirical validation of building energy simulation programs , 1997 .