Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes

Previously, electrical impedance tomography (EIT) has been used to image impedance decreases in the exposed cortex of rabbits during brain activity. These are due to increased blood volume at the site of the stimulated cortex; as blood has a lower impedance than brain, the impedance decreases. During human brain activity similar blood flow changes have been detected using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). If blood volume also changes then the impedance of human cortex will change during brain activity; this could theoretically be imaged with EIT. EIT data were recorded from a ring of 16 scalp electrodes in 34 recordings in 19 adult volunteers before, during and after stimulation with (1) a visual stimulus produced by an 8 Hz oscillating checkerboard pattern or (2) sensory stimulation of the median nerve at the wrist by a 3 Hz electrical square wave stimulus. Reproducible impedance changes, with a similar timecourse to the stimulus, were seen in all experiments. Significant impedance changes were seen in 21 +/- 5% (n = 16, mean +/- SEM) and 19 +/- 3% (n = 18) of the electrode measurements for visual and somatosensory paradigms respectively. The reconstructed 2D EIT images showed reproducible impedance changes in the approximate region of the stimulated cortex in 7/16 visual and 5/18 somatosensory experiments. This demonstrates that reproducible impedance changes can be measured during human brain activity. The final images contained spatial noise; the reasons for this and strategies to reduce this in future are discussed.

[1]  E. Gersing,et al.  Messung der elektrischen Impedanz von Organen — Apparative Ausrüstung für Forschung und klinische Anwendung - Measurement of Electrical Impedance in Organs – Measuring Equipment for Research and Clinical Applications , 1991 .

[2]  B H Brown,et al.  The Sheffield data collection system. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[3]  R H Bayford,et al.  Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation. , 1996, Physiological measurement.

[4]  D S Holder,et al.  Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbit. , 1996, Physiological measurement.

[5]  G. Ojemann,et al.  Optical imaging of epileptiform and functional activity in human cerebral cortex , 1992, Nature.

[6]  J C Mazziotta,et al.  Human sensory stimulation and deprivation: Positron emission tomographic results and strategies , 1984, Annals of neurology.

[7]  J. Allman,et al.  Mapping human visual cortex with positron emission tomography , 1986, Nature.

[8]  D S Holder,et al.  Imaging of cortical spreading depression by EIT: implications for localization of epileptic foci. , 1994, Physiological measurement.

[9]  B H Brown,et al.  Noise and spatial resolution of a real-time electrical impedance tomograph. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  J C Mazziotta,et al.  Effects of stimulus rate on regional cerebral blood flow after median nerve stimulation. , 1995, Brain : a journal of neurology.

[11]  P. Pietrini,et al.  Frequency Variation of a Pattern-Flash Visual Stimulus during PET Differentially Activates Brain from Striate through Frontal Cortex , 1997, NeuroImage.

[12]  D S Holder,et al.  Detection of cerebral ischaemia in the anaesthetised rat by impedance measurement with scalp electrodes: implications for non-invasive imaging of stroke by electrical impedance tomography. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[13]  Paul Kinahan,et al.  A Direct Comparison between Whole-Brain PET and BOLD fMRI Measurements of Single-Subject Activation Response , 1999, NeuroImage.

[14]  Richard H. Bayford,et al.  Three-Dimensional Electrical Impedance Tomography of Human Brain Activity , 2001, NeuroImage.

[15]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[16]  M. Hallett,et al.  The functional neuroanatomy of simple and complex sequential finger movements: a PET study. , 1998, Brain : a journal of neurology.

[17]  R H Bayford,et al.  Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank. , 2001, Physiological measurement.

[18]  J. Gati,et al.  Imaging of current density and current pathways in rabbit brain during transcranial electrostimulation , 1999, IEEE Transactions on Biomedical Engineering.

[19]  B. Rosen,et al.  Functional mapping of the human visual cortex by magnetic resonance imaging. , 1991, Science.