Air, antibiotics and sepsis in replacement joints.

Reducing bacterial contamination of the wound by limiting dispersal from the operating staff through the wearing of special occlusive clothing and by employing directional flow ventilating systems substantially reduces the risk of later joint sepsis. Inhibiting growth of those bacteria which reach the wound, by means of perioperative antibiotics, further reduces the incidence of joint sepsis. When all three means are used together the sepsis rate in the years after operation can be reduced to no more than a few per thousand. The hospital costs of any or all of these measures, in terms of the cases of sepsis avoided, are several times less than the costs of treating a septic joint.

[1]  John Charnley,et al.  Low Friction Arthroplasty of the Hip , 1979 .

[2]  R. Blowers,et al.  Hospital Infection: Causes and Prevention , 1961, Pediatrics.

[3]  O M Lidwell,et al.  Ultraclean air and antibiotics for prevention of postoperative infection. A multicenter study of 8,052 joint replacement operations. , 1987, Acta orthopaedica Scandinavica.

[4]  J. Lister On a Case Illustrating the Present Aspect of the Antiseptic System of Treatment in Surgery , 1871, British medical journal.

[5]  O. Lidwell The Cost Implications of Clean Air Systems and Antibiotic Prophylaxis in Operations for Total Joint Replacement , 1984, Infection Control.

[6]  R. Blowers,et al.  Infection and sepsis after operations for total hip or knee-joint replacement: influence of ultraclean air, prophylactic antibiotics and other factors , 1984, Journal of Hygiene.

[7]  R. Blowers,et al.  Extended follow-up of patients suspected of having joint sepsis after total joint replacement , 1985, Journal of Hygiene.

[8]  R. Blowers,et al.  Design of operating-room dress for surgeons. , 1965, The Lancet.

[9]  O M Lidwell,et al.  Suggested bacteriological standards for air in ultraclean operating rooms. , 1983, The Journal of hospital infection.

[10]  An Address on the Present Position of Antiseptic Surgery , 1890, British medical journal.

[11]  B. B. Roe,et al.  Total Anomalous Pulmonary Venous Drainage, Technical and Physiological Considerations , 1964 .

[12]  O. Lidwell,et al.  Multi-Hospital Trial on the use of Ultraclean Air Systems in Orthopaedic Operating Rooms to Reduce Infection: Preliminary Communication 1 , 1978, Journal of the Royal Society of Medicine.

[13]  J. Lister ON THE EFFECTS OF THE ANTISEPTIC SYSTEM OF TREATMENT UPON THE SALUBRITY OF A SURGICAL HOSPITAL. , 1870 .

[14]  J. Evrard,et al.  PROPHYLACTIC CEFAZOLIN VERSUS PLACEBO IN TOTAL HIP REPLACEMENT Report of a Multicentre Double-blind Randomised Trial , 1981, The Lancet.

[15]  J. Charnley,et al.  Postoperative infection in total prosthetic replacement arthroplasty of the hip‐joint with special reference to the bacterial content of the air of the operating room , 1969, The British journal of surgery.

[16]  O. Lidwell The economics of sepsis control. , 1988, Journal of Hospital Infection.

[17]  L COLEBROOK,et al.  Air hygiene in dressing-rooms for burns or major wounds. , 1946, Lancet.

[18]  O M Lidwell,et al.  Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. , 1982, British medical journal.

[19]  O M Lidwell,et al.  Airborne contamination of wounds in joint replacement operations: the relationship to sepsis rates. , 1983, The Journal of hospital infection.

[20]  P. Trexler An isolator system for the maintenance of aseptic environments. , 1973, Lancet.

[21]  G. W. Snedecor Statistical Methods , 1964 .

[22]  J. Duguid,et al.  Air infection with dust liberated from clothing. , 1948, Lancet.

[23]  J. Lister Observations ON LIGATURE OF ARTERIES ON THE ANTISEPTIC SYSTEM. , 1869 .

[24]  W. Noble,et al.  Dispersal of bacteria on desquamated skin. , 1962, Lancet.

[25]  J CHARNLEY,et al.  A clean‐air operating enclosure , 1964, The British journal of surgery.

[26]  O M Lidwell,et al.  The dimensions of skin fragments dispersed into the air during activity , 1978, Journal of Hygiene.

[27]  R. Blowers,et al.  Bacteria isolated from deep joint sepsis after operation for total hip or knee replacement and the sources of the infections with Staphylococcus aureus. , 1983, The Journal of hospital infection.

[28]  J. Charley A sterile‐air operating theatre enclosure , 1964 .