Distribution measurements of 3,4-methylenedioxymethamphetamine and its metabolites in organs by matrix-assisted laser desorption/ionization imaging mass spectrometry using an automatic matrix spraying system with an air brush and a turntable

Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI/IMS) is a useful tool for measuring drug distributions. To obtain reproducible analytical results with MALDI/IMS, it is essential to apply a homogeneous matrix coating onto sample surfaces. A simple and inexpensive automatic matrix spraying system (AMSS) with good reproducibility was developed in this study. In addition, drug distributions in organs were measured by MALDI/IMS using the AMSS for forensic toxicology applications. The AMSS was constructed from simple components, including an air brush, a turntable, and a microscope. Organ slices placed onto conductive sheets were attached to the turntable. The trigger of the air brush was held with a clamp to ensure that it sprayed continuously onto a defined area of the table. Periodic spraying of the matrix solution and evaporation of solvent were performed by rotating the turntable. The droplets and crystals on the sample surfaces were observed under a microscope attached to the turntable. The droplet size, rotation rate of the turntable, and the formulation of the matrix solution were optimized. The homogeneity of the matrix coating was evaluated using the coefficients of variation (CV) obtained by quantifying the color density of the sheet surface. The AMSS enabled more homogeneous matrix coating (intersheet CV = 5.4 %) than manual spraying (intersheet CV = 16.7 %) when 10 mL of 0.5 % aqueous trifluoroacetic acid/acetonitrile (1:3, v/v) containing 10 mg/mL α-cyano-4-hydroxycinnamic acid were sprayed as droplets less than 50 μm in diameter onto a turntable rotating at 30 rpm. The distributions of 3,4-methylenedioxymethamphetamine (MDMA) and its main metabolites in the brain, liver, and kidney of a mouse that died from an MDMA overdose (58 mg/kg i.p.) were visualized by MALDI/IMS using the AMSS. The ion intensities of MDMA obtained from the same regions on three sequential kidney slices showed acceptable variations (CV = 2.9–8.8 % for five different regions), implying repeatable measurements with MALDI/IMS using the AMSS. It was revealed that MDMA was particularly concentrated around the brain stem and the major calix of the kidney. The AMSS would be suitable for preparing samples for measuring the distributions of drugs in organs at toxic dose levels in forensic toxicological applications.

[1]  H. Kalant,et al.  The pharmacology and toxicology of "ecstasy" (MDMA) and related drugs. , 2001, CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne.

[2]  J. Cadet,et al.  Methylenedioxymethamphetamine (MDMA, Ecstasy) neurotoxicity: cellular and molecular mechanisms , 2003, Brain Research Reviews.

[3]  C. Jurado,et al.  Tissue concentrations of MDMA and its metabolite MDA in three fatal cases of overdose. , 2003, Forensic science international.

[4]  V. Fineschi,et al.  Fatal poisoning by MDMA (ecstasy) and MDEA: A case report , 2005, International Journal of Legal Medicine.

[5]  Richard M Caprioli,et al.  Automated acoustic matrix deposition for MALDI sample preparation. , 2006, Analytical chemistry.

[6]  R. Caprioli,et al.  Direct molecular analysis of whole-body animal tissue sections by imaging MALDI mass spectrometry. , 2006, Analytical chemistry.

[7]  Richard A Yost,et al.  Automated MALDI matrix deposition method with inkjet printing for imaging mass spectrometry. , 2007, Analytical chemistry.

[8]  S. Deininger,et al.  MALDI tissue imaging: mass spectrometric localization of biomarkers in tissue slices , 2007 .

[9]  T. Michiue,et al.  Postmortem serum catecholamine levels in relation to the cause of death. , 2007, Forensic science international.

[10]  K. Woźniak,et al.  Fatality due to the use of a designer drug MDMA (Ecstasy). , 2007, Legal medicine.

[11]  M. Clench,et al.  Matrix-assisted laser desorption/ionization-ion mobility separation-mass spectrometry imaging of vinblastine in whole body tissue sections. , 2008, Analytical chemistry.

[12]  Ying Liu,et al.  Imaging MALDI mass spectrometry using an oscillating capillary nebulizer matrix coating system and its application to analysis of lipids in brain from a mouse model of Tay-Sachs/Sandhoff disease. , 2008, Analytical chemistry.

[13]  K. Owens,et al.  Development of a dual-spray electrospray deposition system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. , 2008, Rapid communications in mass spectrometry : RCM.

[14]  T. Kondo,et al.  Distribution of zolpidem in body fluids and organ tissues in five autopsy cases , 2008, Forensic Toxicology.

[15]  M. Stoeckli,et al.  Matrix-assisted laser desorption/ionization mass spectrometric imaging of complete rat sections using a triple quadrupole linear ion trap. , 2009, Rapid communications in mass spectrometry : RCM.

[16]  K. Owens,et al.  Optimization of a modified aerospray deposition device for the preparation of samples for quantitative analysis by MALDI-TOFMS. , 2010, Analytica chimica acta.

[17]  J. Walker,et al.  Automated solvent-free matrix deposition for tissue imaging by mass spectrometry. , 2010, Analytical chemistry.

[18]  B. Spengler,et al.  Matrix vapor deposition/recrystallization and dedicated spray preparation for high-resolution scanning microprobe matrix-assisted laser desorption/ionization imaging mass spectrometry (SMALDI-MS) of tissue and single cells. , 2010, Rapid communications in mass spectrometry : RCM.

[19]  J. Cadet,et al.  (±)-3,4-methylenedioxymethamphetamine and metabolite disposition in plasma and striatum of wild-type and multidrug resistance protein 1a knock-out mice. , 2011, Journal of analytical toxicology.

[20]  K. Kuwayama,et al.  Distribution measurement of amphetamine-type stimulants in organs using micropulverized extraction and liquid chromatography/tandem mass spectrometry to complement drug distribution using mass spectrometry imaging. , 2011, Rapid communications in mass spectrometry : RCM.

[21]  C. Milroy,et al.  “Ecstasy” associated deaths: what is a fatal concentration ? Analysis of a case series , 2011, Forensic science, medicine, and pathology.

[22]  T. Takubo,et al.  Imaging of methamphetamine incorporated into hair by MALDI-TOF mass spectrometry , 2011, Forensic Toxicology.