Water pollutant monitoring by a whole cell array through lens-free detection on CCD.

Environmental contamination has become a serious problem to human and environmental health, as exposure to a wide range of possible contaminants continuously increases due to industrial and agricultural activities. Whole cell sensors have been proposed as a powerful tool to detect class-specific toxicants based upon their biological activity and bioavailability. We demonstrated a robust toxicant detection platform based on a bioluminescence whole cell sensor array biochip (LumiChip). LumiChip harbors an integrated temperature control and a 16-member sensor array, as well as a simple but highly efficient luminescence collection setup. On LumiChip, samples were infused in an oxygen-permeable microfluidic flow channel to reach the sensor array. Time-lapse changes in bioluminescence emitted by the array members were measured on a single window-removed linear charge-coupled device (CCD) commonly used in commercial industrial process control or in barcode readers. Removal of the protective window on the linear CCD allowed lens-free direct interfacing of LumiChip to the CCD surface for measurement with high light collection efficiency. Bioluminescence induced by simulated contamination events was detected within 15 to 45 minutes. The portable LumiSense system utilizing the linear CCD in combination with the miniaturized LumiChip is a promising potential platform for on-site environmental monitoring of toxicant contamination.

[1]  Shimshon Belkin,et al.  Are luminescent bacteria suitable for online detection and monitoring of toxic compounds in drinking water and its sources? , 2010, Analytical and bioanalytical chemistry.

[2]  Kiyohito Yagi,et al.  Applications of whole-cell bacterial sensors in biotechnology and environmental science , 2007, Applied Microbiology and Biotechnology.

[3]  P. Wei,et al.  Magnetic nanoparticle-enhanced SPR on gold nanoslits for ultra-sensitive, label-free detection of nucleic acid biomarkers. , 2013, The Analyst.

[4]  Shimshon Belkin,et al.  Bioluminescent whole cell optical fiber sensor to genotoxicants: system optimization , 2001 .

[5]  Aydogan Ozcan,et al.  Wide-field lensless fluorescent microscopy using a tapered fiber-optic faceplate on a chip. , 2011, The Analyst.

[6]  J. M. Rochelle,et al.  Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit. , 2002, Sensors and actuators. B, Chemical.

[7]  Yosi Shacham-Diamand,et al.  Online monitoring of water toxicity by use of bioluminescent reporter bacterial biochips. , 2011, Environmental science & technology.

[8]  Aydogan Ozcan,et al.  Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects , 2010, Optics express.

[9]  Elisa Michelini,et al.  A portable bioluminescence engineered cell-based biosensor for on-site applications. , 2011, Biosensors & bioelectronics.

[10]  Pascal Picart,et al.  A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor , 2011, Analytical and bioanalytical chemistry.

[11]  Cheng-Wey Wei,et al.  Direct-write laser micromachining and universal surface modification of PMMA for device development , 2004 .

[12]  Aydogan Ozcan,et al.  Biomedical imaging and sensing using flatbed scanners. , 2014, Lab on a chip.

[13]  S. Belkin Microbial whole-cell sensing systems of environmental pollutants. , 2003, Current opinion in microbiology.

[14]  A. Ozcan,et al.  High-throughput screening of large volumes of whole blood using structured illumination and fluorescent on-chip imaging. , 2012, Lab on a chip.

[15]  R D Schmid,et al.  Reporter gene bioassays in environmental analysis , 2000, Fresenius' journal of analytical chemistry.

[16]  Aydogan Ozcan,et al.  Wide field-of-view lens-free fluorescent imaging on a chip. , 2010, Lab on a chip.

[17]  Shimshon Belkin,et al.  Upgrading bioluminescent bacterial bioreporter performance by splitting the lux operon , 2011, Analytical and bioanalytical chemistry.

[18]  Syed Kamrul Islam,et al.  Integrated Circuit Biosensors Using Living Whole-Cell Bioreporters , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[19]  Robert S. Marks,et al.  Whole-cell aquatic biosensors , 2011, Analytical and bioanalytical chemistry.

[20]  Kangil Kim,et al.  The optimization of PDMS-PMMA bonding process using silane primer , 2010 .

[21]  S. Belkin,et al.  Where microbiology meets microengineering: design and applications of reporter bacteria , 2010, Nature Reviews Microbiology.

[22]  Michael J. Paulus,et al.  Bioluminescent-bioreporter integrated circuits form novel whole-cell biosensors , 1998 .

[23]  Matti Karp,et al.  Generation of thermostable monomeric luciferases from Photorhabdus luminescens. , 2002, Biochemical and biophysical research communications.

[24]  G. Gil,et al.  A multi-channel continuous toxicity monitoring system using recombinant bioluminescent bacteria for classification of toxicity. , 2001, Biosensors & bioelectronics.

[25]  R. Larossa,et al.  Oxidative stress detection with Escherichia coli harboring a katG'::lux fusion , 1996 .

[26]  Aydogan Ozcan,et al.  Lensfree Fluorescent On-Chip Imaging of Transgenic Caenorhabditis elegans Over an Ultra-Wide Field-of-View , 2011, PloS one.

[27]  Man Bock Gu,et al.  An integrated mini biosensor system for continuous water toxicity monitoring. , 2005, Biosensors & bioelectronics.

[28]  S. Belkin,et al.  Mathematical Modeling of a Bioluminescent E. Coli Based Biosensor , 2009 .

[29]  A. Agranat,et al.  Simultaneous quantification of the fluorescent responses of an ensemble of bacterial sensors. , 2013, Biosensors & bioelectronics.

[30]  Yosi Shacham-Diamand,et al.  Development of a quantitative optical biochip based on a double integrating sphere system that determines absolute photon number in bioluminescent solution: application to quantum yield scale realization. , 2009, Applied optics.

[31]  Stefano Girotti,et al.  Monitoring of environmental pollutants by bioluminescent bacteria. , 2008, Analytica chimica acta.

[32]  Craig R Forest,et al.  Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood. , 2012, Lab on a chip.

[33]  E. Stackebrandt,et al.  Xenorhabdus and Photorhabdus spp.: bugs that kill bugs. , 1997, Annual review of microbiology.

[34]  Shimshon Belkin,et al.  Escherichia coli bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene , 2013, Applied Microbiology and Biotechnology.

[35]  Ji-Yen Cheng,et al.  Performing microchannel temperature cycling reactions using reciprocating reagent shuttling along a radial temperature gradient. , 2005, The Analyst.

[36]  Elisa Michelini,et al.  Bioengineered bioluminescent magnetotactic bacteria as a powerful tool for chip-based whole-cell biosensors. , 2013, Lab on a chip.

[37]  C. Lim,et al.  Rapid quantification of live cell receptors using bioluminescence in a flow-based microfluidic device. , 2015, Small.

[38]  R. Larossa,et al.  Improved bacterial SOS promoter∷lux fusions for genotoxicity detection. , 2000, Mutation research.

[39]  M. Gu,et al.  Geno-Tox: Cell Array Biochip for Genotoxicity Monitoring and Classification , 2012, Applied Biochemistry and Biotechnology.

[40]  A. Ozcan,et al.  Ultra wide-field lens-free monitoring of cells on-chip. , 2008, Lab on a chip.

[41]  Aydogan Ozcan,et al.  Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy , 2012, Nature Methods.

[42]  Shimshon Belkin,et al.  Modeling and measurement of a whole-cell bioluminescent biosensor based on a single photon avalanche diode. , 2008, Biosensors & bioelectronics.

[43]  Meng-Hua Yen,et al.  Electrotaxis of lung cancer cells in a multiple-electric-field chip. , 2009, Biosensors & bioelectronics.

[44]  G. Barrett,et al.  Genetically engineered whole-cell sensing systems: coupling biological recognition with reporter genes. , 2000, Chemical reviews.

[45]  M. J. Cormier,et al.  Quantum efficiency determinations on components of the bacterial luminescence system. , 1957, Biochimica et biophysica acta.

[46]  Ji-Yen Cheng,et al.  Electrotaxis of oral squamous cell carcinoma cells in a multiple-electric-field chip with uniform flow field. , 2012, Biomicrofluidics.