Long term in vitro monitoring of polyimide microprobe electrical properties

In vitro soak tests lasting over 400 days were performed on polyimide sieve electrodes (PI2611D) using a method that allows in situ measurement of the impedance and relative dielectric constant of polyimide or alternate polymers. It was found that following an initial period of change, both values stabilized after a period of about 100 days. The dielectric constant was measured at 1 kHz and found to increase by 18% over 406 days. A short-term comparison (23 days) between polyimide cured on a hotplate in air versus using an oven with N/sub 2/ was also performed. No difference could be seen between the 2 methods.

[1]  Daryl R. Kipke,et al.  3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..

[2]  Daryl R. Kipke,et al.  Advanced neural implants using thin-film polymers , 2002, 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353).

[3]  T. Stieglitz,et al.  Immunohistochemical characterization of axonal sprouting and reactive tissue changes after long-term implantation of a polyimide sieve electrode to the transected adult rat sciatic nerve. , 2001, Biomaterials.

[4]  T. Stieglitz Flexible biomedical microdevices with double-sided electrode arrangements for neural applications , 2001 .

[5]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[6]  T. Stieglitz,et al.  Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .

[7]  K. Mabuchi,et al.  Flexible microelectrode for interfacing regenerating peripheral nerves , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[8]  M. Kosaki,et al.  Open-circuit voltage and short-circuit current characteristics of moisture absorbed polyimide thin films with different electrode materials , 1997, Proceedings of 5th International Conference on Properties and Applications of Dielectric Materials.

[9]  Thomas Stieglitz,et al.  A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves , 1997 .

[10]  B. Wheeler,et al.  A flexible perforated microelectrode array for extended neural recordings , 1992, IEEE Transactions on Biomedical Engineering.

[11]  H. K. Charles,et al.  Multisite microprobes for neural recordings , 1991, IEEE Transactions on Biomedical Engineering.