In this paper, a 600kw 4200rpm interior permanent magnet (IPM) traction motor for high-speed train has been designed, and its characteristics under typical short-circuit faults are particularly analyzed using the finite element method (FEM), especially the short-circuit current. Solutions and fault tolerance ability for short-circuit faults are proposed according to the analysis above. Furthermore, key design parameters of the IPM traction motor influencing the short-circuit current are discussed in order to provide some methods to reinforce the short-circuit fault tolerance ability.
[1] B. Nahid-Mobarakeh,et al. Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis , 2011, IEEE Transactions on Industry Applications.
[2] T. M. Jahns,et al. IPM Synchronous Machine Drive Response to Symmetrical and Asynunetrical Short Circuit Faults , 2002, IEEE Power Engineering Review.