An in vivo verification of the intravoxel incoherent motion effect in diffusion‐weighted imaging of the abdomen

To investigate the vascular contribution to the measured apparent diffusion coefficient and to validate the Intra Voxel Incoherent Motion theory, the signal as a function of the b‐value was measured in the healthy pancreas with and without suppression of the vascular component and under varying echo times (TE = 50, 70, and 100 msec). The perfusion fraction f and the diffusion coefficient D were extracted from the measured DW‐data using the original Intra Voxel Incoherent Motion‐equation and a modified version of this equation incorporating relaxation effects. First, the perfusion fraction f in the blood suppressed pancreatic tissue decreased significantly (P = 0.03), whereas the diffusion coefficient D did not change with suppression (P = 0.43). Second, the perfusion fraction f increased significantly with increasing echo time (P = 0.0025), whereas the relaxation time compensated perfusion fraction f′ showed no significant dependence on TE (P = 0.31). These results verify a vascular contribution to the diffusion weighted imaging measurement at low b values and support the Intra Voxel Incoherent Motion‐theory. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Bram Stieltjes,et al.  Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values: Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Derived Parameters , 2009, Investigative radiology.

[2]  Namkug Kim,et al.  Quantitative analysis of diffusion‐weighted magnetic resonance imaging of the pancreas: Usefulness in characterizing solid pancreatic masses , 2008, Journal of magnetic resonance imaging : JMRI.

[3]  Seong-Gi Kim,et al.  Quantification of cerebral arterial blood volume using arterial spin labeling with intravoxel incoherent motion‐sensitive gradients , 2006, Magnetic resonance in medicine.

[4]  Seong-Gi Kim,et al.  In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain , 2000, Magnetic resonance in medicine.

[5]  M. Raichle,et al.  The Effects of Changes in PaCO2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time , 1974, Stroke.

[6]  A. Luciani,et al.  Liver Cirrhosis : Intravoxel Incoherent Motion MR Imaging — Pilot Study 1 , 2008 .

[7]  M D King,et al.  Perfusion and diffusion MR imaging , 1992, Magnetic resonance in medicine.

[8]  C T Moonen,et al.  On the precision of diffusion/perfusion imaging by gradient sensitization , 1992, Magnetic resonance in medicine.

[9]  Ultrafast MR imaging of water mobility: Animal models of altered cerebral perfusion , 1992, Journal of magnetic resonance imaging : JMRI.

[10]  T. Kessler,et al.  Noninvasive assessment of acute ureteral obstruction with diffusion-weighted MR imaging: a prospective study. , 2009, Radiology.

[11]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[12]  Richard S. J. Frackowiak,et al.  Cerebral blood flow, blood volume and oxygen utilization. Normal values and effect of age. , 1990, Brain : a journal of neurology.

[13]  T E Conturo,et al.  Diffusion MRI: Precision, accuracy and flow effects , 1995, NMR in biomedicine.

[14]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[15]  N. Rofsky,et al.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. , 2004, Radiology.

[16]  T. Murakami,et al.  Quantitative tissue blood flow evaluation of pancreatic tumor: comparison between xenon CT technique and perfusion CT technique based on deconvolution analysis. , 2005, Radiation medicine.

[17]  T. A. Carpenter,et al.  Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain. , 1997, Magnetic resonance imaging.

[18]  R M Henkelman,et al.  A quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain , 1994, Magnetic resonance in medicine.

[19]  M. Décorps,et al.  Methodology of brain perfusion imaging , 2001, Journal of magnetic resonance imaging : JMRI.

[20]  The use of slice-selective inversion to improve the dynamic range for measurement of pseudodiffusion coefficient , 1992 .

[21]  J. Pearlman,et al.  CSF‐suppressed quantitative single‐shot diffusion imaging , 1991, Magnetic resonance in medicine.

[22]  J R MacFall,et al.  Diffusion/microcirculation MRI in the rat brain , 1991, Magnetic resonance in medicine.

[23]  Jeffrey J. Neil,et al.  Detection of pseudodiffusion in rat brain following blood substitution with perfluorocarbon , 1992 .

[24]  Robert Turner,et al.  The capillary network: a link between ivim and classical perfusion , 1992, Magnetic resonance in medicine.

[25]  D. Le Bihan,et al.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. , 1988, Radiology.

[26]  B. Sykes,et al.  Water Eliminated Fourier Transform NMR Spectroscopy , 1972 .

[27]  D. Le Bihan Molecular diffusion, tissue microdynamics and microstructure. , 1995, NMR in biomedicine.

[28]  D. Norris The effects of microscopic tissue parameters on the diffusion weighted magnetic resonance imaging experiment , 2001, NMR in biomedicine.

[29]  Hiroshi Yamamoto,et al.  Perfusion computerized tomography can predict pancreatic necrosis in early stages of severe acute pancreatitis. , 2007, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[30]  J J Neil,et al.  An evaluation of the sensitivity of the intravoxel incoherent motion (IVIM) method of blood flow measurement to changes in cerebral blood flow , 1994, Magnetic resonance in medicine.

[31]  Junichiro Shimizu,et al.  Measurement of canine pancreatic perfusion using dynamic computed tomography: influence of input-output vessels on deconvolution and maximum slope methods. , 2011, European journal of radiology.