IFCC Scientific Division Committee on Point of Care Testing

Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal win this document, ‘‘plasma’’ refers to circulating plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or ‘‘blood’’), plasma separated from blood cells, or serumx. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is ‘‘the concentration of ionized magnesium in plasma’’. Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4% lower than the true molality in plasma. Calcium ions interfere with all current magnesium ion-selective electrodes (Mg-ISEs), and thus it is necessary to determine both ions simultaneously in each sample and correct the result for Caq interference. Binding of Mg in plasma is pH-dependent. Therefore, pH should be measured simultaneously with iMg to allow adjustment of the result to pH 7.4. 22 Ben Rayana et al.: IFCC Guideline for sampling, measuring and reporting ionized magnesium Article in press uncorrected proof The concentration of iMg in plasma may be physiologically and clinically more relevant than the concentration of total magnesium. Furthermore, blood-gas analyzers or instruments for point-of-care testing are able to measure plasma iMg using whole blood (with intact blood cells) as the sample, minimizing turnaround time compared to serum and plasma, which require removal of blood cells. Clin Chem Lab Med 2008;46:21–6.

[1]  T. M. Brown,et al.  By Electrochemical methods , 2007 .

[2]  A. Lewenstam,et al.  Numerical Solution of the Coupled Nernst-Planck and Poisson Equations for Liquid Junction and Ion Selective Membrane Potentials , 2003 .

[3]  Andrzej Lewenstam,et al.  Application of Nernst–Planck and Poisson equations for interpretation of liquid-junction and membrane potentials in real-time and space domains , 2001 .

[4]  W. Zijlstra,et al.  Use of Ion-Selective Electrodes for Blood-Electrolyte Analysis. Recommendations for Nomenclature, Definitions and Conventions , 2000, Clinical chemistry and laboratory medicine.

[5]  N E Saris,et al.  Magnesium. An update on physiological, clinical and analytical aspects. , 2000, Clinica chimica acta; international journal of clinical chemistry.

[6]  O. Siggaard‐Andersen,et al.  IFCC Recommended Reference Method for the Determination of the Substance Concentration of Ionized Calcium in Undiluted Serum, Plasma or Whole Blood , 2000, Clinical chemistry and laboratory medicine.

[7]  M. Meyerhoff,et al.  Potentiometric response of magnesium-selective membrane electrode in the presence of nonionic surfactants , 1999 .

[8]  G. Sanders,et al.  Serum Ionized Magnesium: Comparison of Results Obtained with Three Ion-Selective Analyzers , 1999, Clinical chemistry and laboratory medicine.

[9]  G. Csako,et al.  Falsely high ionized magnesium results by an ion-selective electrode method in severe hypomagnesemia. , 1997, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[10]  J. Niemela,et al.  Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode. , 1997, Clinical chemistry.

[11]  G. Sanders,et al.  Magnesium fractions in serum of healthy individuals and CAPD patients, measured by an ion-selective electrode and ultrafiltration. , 1996, Clinical biochemistry.

[12]  O. Siggaard‐Andersen,et al.  Changes in plasma ionized calcium and magnesium in blood donors after donation of 450 mL blood. Effects of hemodilution and Donnan equilibrium. , 1996, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[13]  W. Külpmann,et al.  Ionized magnesium concentration during liver transplantation, resection of the liver and cardiac surgery. , 1996, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[14]  R. Brunkhorst,et al.  Ionised and Total Magnesium Serum Concentrations in Renal and Hepatic Diseases , 1996, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[15]  J. Niemela,et al.  Analyzer-dependent differences in results for ionized calcium, ionized magnesium, sodium, and pH. , 1995, Clinical chemistry.

[16]  O. Siggaard‐Andersen,et al.  Composition of interstitial fluid. , 1995, Clinical chemistry.

[17]  O. Siggaard‐Andersen,et al.  International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Approved IFCC recommendations on whole blood sampling, transport and storage for simultaneous determination of pH, blood gases and electrolytes. , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[18]  M. Lyon,et al.  Zinc heparin introduces a preanalytical error in the measurement of ionized calcium concentration. , 1995, Scandinavian journal of clinical and laboratory investigation.

[19]  M. Lyon,et al.  Specific heparin preparations interfere with the simultaneous measurement of ionized magnesium and ionized calcium. , 1995, Clinical biochemistry.

[20]  A. Okorodudu,et al.  A Method for the Measurement of Ionized Magnesium , 1995 .

[21]  R. DeFronzo,et al.  Fluid, electrolyte, and acid-base disorders , 1995 .

[22]  A. Jeremias,et al.  Measurement of Free Magnesium in Blood, Serum and Plasma with an Ion-Sensitive Electrode , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[23]  M. Landt,et al.  Interference of zinc heparin anticoagulant in determination of plasma magnesium. , 1994, Clinical chemistry.

[24]  B. Altura,et al.  A method for distinguishing ionized, complexed and protein-bound Mg in normal and diseased subjects. , 1994, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[25]  H. Offenbacher,et al.  Measurement of ionized magnesium with neutral carrier based ISE's. Progress and results with the AVL 988-4 magnesium analyzer. , 1994, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[26]  A. Lewenstam,et al.  Characterization, standardization and experiences with KONE ISE for Mg2+. , 1994, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[27]  O. Siggaard‐Andersen,et al.  Standardizing and reporting results from Mg2+ ISEs, with some notes on sample handling. , 1994, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[28]  G. Sanders,et al.  Analytical evaluation of Kone Microlyte determination of ionized magnesium. , 1994, Clinical chemistry.

[29]  O. Siggaard‐Andersen,et al.  IFCC recommendation on sampling, transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum , 1991, The Journal of automatic chemistry.

[30]  W. Simon,et al.  Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum. , 1990, Clinical chemistry.

[31]  A. Lewenstam,et al.  Fully automated potentiometric determination of ionized magnesium in blood serum , 1990 .

[32]  M H Kroll,et al.  Relationships between magnesium and protein concentrations in serum. , 1985, Clinical chemistry.

[33]  O. Siggaard‐Andersen,et al.  Acid-base-induced changes in the distribution of water between plasma and erythrocytes, as measured with a sodium-ion-selective electrode. , 1984, Clinical chemistry.