A high-precision and fast-sampling frequency measurement method based on FPGA carry chain for airborne optically pumped cesium magnetometer.

Improving the precision and sampling rate of the resonance frequency of cesium atoms is the key to enhancing the same factors of an airborne optically pumped cesium magnetometer (AOPCM). Aiming at the existed problems of AOPCM and characteristics of resonance signal, this paper proposes a high-precision and fast-sampling frequency measurement method based on carry chains of Field-Programmable Gate Array (FPGA). In order to achieve a fast-sampling rate, an improved equal precision frequency measurement method is proposed to measure the standard signal and the resonance signal continuously. Besides, by using the serial full adder to connect FPGA carry chains to a delay line, the delay line is used to compensate the unsynchronized clock edge, so the counting error can be reduced, and the precision of frequency measurement can be improved greatly. Experiments show that the frequency resolution is 0.014 nT and the relative error is lower than 2 × 10-6 when the sampling rate is 500 Hz. The experimental result indicates that the proposed method improves the precision and sampling rate of resonance frequency measurement greatly. Consequently, the precision and sampling rate of AOPCM can be improved.

[1]  Huan Liu,et al.  A High-Precision Frequency Measurement Algorithm for FID Signal of Proton Magnetometer , 2016, IEEE Transactions on Instrumentation and Measurement.

[2]  J. Lenz,et al.  Magnetic sensors and their applications , 2006, IEEE Sensors Journal.

[3]  D. Budker,et al.  Optical magnetometry - eScholarship , 2006, physics/0611246.

[4]  J. Kitching,et al.  Atomic Sensors – A Review , 2011, IEEE Sensors Journal.

[5]  Shuang Zhang,et al.  An improved Overhauser magnetometer for Earth's magnetic field observation , 2016, Optical Engineering + Applications.

[6]  Cheolgi Kim,et al.  OPTICAL PUMPING MAGNETIC RESONANCE IN CS ATOMS FOR USE IN PRECISE LOW-FIELD MAGNETOMETRY , 1998 .

[7]  K.-H. Jäckel,et al.  A new optically pumped tandem magnetometer: principles and experiences , 1999 .

[8]  Marcin Kowalski,et al.  High resolution time-interval measurement systems applied to flow measurement , 2014 .

[9]  Gerardo Noriega,et al.  Aeromagnetic Compensation in Gradiometry—Performance, Model Stability, and Robustness , 2015, IEEE Geoscience and Remote Sensing Letters.

[10]  G. Bison,et al.  A high-sensitivity laser-pumped Mx magnetometer , 2004, physics/0406105.

[12]  Huan Liu,et al.  Research on a secondary tuning algorithm based on SVD & STFT for FID signal , 2016 .

[13]  Josef Lazar,et al.  Methods for Measurement and Verification of Purity of Iodine Cells for Laser Frequency Stabilization , 2008 .

[14]  P. J. Hood History of aeromagnetic surveying in Canada , 2007 .