Functional Magnetic Resonance Imaging in a Low-Field Intraoperative Scanner

Background: Functional magnetic resonance imaging (fMRI) has been used for preoperative planning and intraoperative surgical navigation. However, most experience to date has been with preoperative images acquired on high-field echoplanar MRI units. We explored the feasibility of acquiring fMRI of the motor cortex with a dedicated low-field intraoperative MRI (iMRI). Methods: Five healthy volunteers were scanned with the 0.12-tesla PoleStar N-10 iMRI (Odin Medical Technologies, Israel). A finger-tapping motor paradigm was performed with sequential scans, acquired alternately at rest and during activity. In addition, scans were obtained during breath holding alternating with normal breathing. The same paradigms were repeated using a 3-tesla MRI (Siemens Corp., Allandale, N.J., USA). Statistical analysis was performed offline using cross-correlation and cluster techniques. Data were resampled using the ‘jackknife’ process. The location, number of activated voxels and degrees of statistical significance between the two scanners were compared. Results: With both the 0.12- and 3-tesla imagers, motor cortex activation was seen in all subjects to a significance of p < 0.02 or greater. No clustered pixels were seen outside the sensorimotor cortex. The resampled correlation coefficients were normally distributed, with a mean of 0.56 for both the 0.12- and 3-tesla scanners (standard deviations 0.11 and 0.08, respectively). The breath holding paradigm confirmed that the expected diffuse activation was seen on 0.12- and 3-tesla scans. Conclusions: Accurate fMRI with a low-field iMRI is feasible. Such data could be acquired immediately before or even during surgery. This would increase the utility of iMRI and allow for updated intraoperative functional imaging, free of the limitations of brain shift.

[1]  Michael A Vogelbaum,et al.  Intracranial navigation by using low-field intraoperative magnetic resonance imaging: preliminary experience. , 2002, Journal of neurosurgery.

[2]  W. Harkness,et al.  Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation. , 1998, Journal of neurosurgery.

[3]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[4]  B. Bergquist Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit. , 2000, Neurosurgery.

[5]  G. Sutherland,et al.  Utility of a Moveable 1.5 Tesla Intraoperative MR Imaging System , 1999, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[6]  A. Holodny,et al.  Functional Magnetic Resonance Image-Guided Surgery of Tumors in or near the Primary Visual Cortex , 2000, Stereotactic and Functional Neurosurgery.

[7]  G. Sutherland,et al.  Advances in mobile intraoperative magnetic resonance imaging. , 2000, Neurosurgery.

[8]  B. Biswal,et al.  Use of Jackknife Resampling Techniques to Estimate the Confidence Intervals of fMRI Parameters , 2001, Journal of computer assisted tomography.

[9]  O. Ganslandt,et al.  Intraoperative imaging with open magnetic resonance imaging and neuronavigation , 2000, Child's Nervous System.

[10]  P. Black,et al.  Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit. , 1999, Neurosurgery.

[11]  J. Maldjian,et al.  Functional image-guided surgery of intracranial tumors located in or near the sensorimotor cortex. , 1998, Journal of neurosurgery.

[12]  W. Hall,et al.  Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery. , 2000, Neurosurgery.

[13]  H. Berkenstadt,et al.  Novel, Compact, Intraoperative Magnetic Resonance Imaging-guided System for Conventional Neurosurgical Operating Rooms , 2001, Neurosurgery.

[14]  J. Tsuruda,et al.  Integration of preoperative and intraoperative functional brain mapping in a frameless stereotactic environment for lesions near eloquent cortex. Technical note. , 1999, Journal of neurosurgery.

[15]  J. Hajnal,et al.  Imaging of human brain activity at 0.15 T using fluid attenuated inversion recovery (FLAIR) pulse sequences , 1993, Magnetic resonance in medicine.