Joint reconstruction of activity and attenuation in non-TOF PET using a synergistic prior to enforce structural similarities

This study investigates the use of a synergistic edge-preserving prior for a maximum-likelihood reconstruction of PET activity and attenuation images. The effect of the prior was tested on different reconstruction methods: MLAA and our algorithm MLAA-EB-S. Simple simulations on cylindrical phantoms with an insert showed that the presence of a synergistic prior enforces cross-talk related edges when the images are reconstructed with non-TOF MLAA and increases the bias in both the reconstructed activity and attenuation images. However, benefits appear when the joint problem is less ill-posed, as in the case of our method MLAA-EB-S, which exploits scatter information to improve conditioning. Overall, MLAA-EB-S with synergistic prior achieved the lowest bias and variance in both the activity and the attenuation images amongst the compared methods. Therefore, the proposed synergistic prior could be a useful way for improving the performance of MLAA-EB-S without the need of relying on anatomical images.

[1]  Patrick J La Rivière,et al.  Joint reconstruction of multi-channel, spectral CT data via constrained total nuclear variation minimization , 2014, Physics in medicine and biology.

[2]  Jorge Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[3]  Kristian Bredies,et al.  Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer , 2017, IEEE Transactions on Medical Imaging.

[4]  David Atkinson,et al.  Joint reconstruction of PET-MRI by exploiting structural similarity , 2014, Inverse Problems.

[5]  D. Newport,et al.  A Single Scatter Simulation Technique for Scatter Correction in 3D PET , 1996 .

[6]  Nassir Navab,et al.  Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Brian F. Hutton,et al.  Maximum-likelihood estimation of emission and attenuation images in 3D PET from multiple energy window measurements , 2018, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).

[8]  Patrick Dupont,et al.  Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms , 1999, IEEE Transactions on Medical Imaging.

[9]  Alexander Hammers,et al.  Multi‐modal synergistic PET and MR reconstruction using mutually weighted quadratic priors , 2018, Magnetic resonance in medicine.

[10]  S. Ourselin,et al.  PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques , 2019, Medical physics.

[11]  Alexander Hammers,et al.  Synergistic PET and SENSE MR Image Reconstruction Using Joint Sparsity Regularization , 2018, IEEE Transactions on Medical Imaging.