Flow velocity patterns in and distensibility of the carotid artery bulb in subjects of various ages.

Velocity patterns in and distensibility of the carotid artery bulb were studied in younger (20 to 30 years; n = 11) and older (50 to 60 years; n = 9) volunteers without detectable lesions of the cervical carotid arteries by means of a high-resolution, multigate, pulsed Doppler system coupled to a B mode imager. In the bulb the axial velocities were highest on the side of the flow divider, while regions of flow separation and recirculation were observed on the side opposite to this divider. Flow separation and recirculation were less pronounced and less common in the older subjects. Flow separation was not continuously present throughout the cardiac cycle. The distensibility of the carotid arteries was significantly diminished in older subjects, especially in the bulb. The velocity patterns in the carotid artery bulb of younger subjects corroborate the patterns observed in models. The diminished flow separation and recirculation in the older subjects might result from alterations in distensibility at the transition from common to internal carotid artery with increasing age.

[1]  A. Svindland,et al.  Localization of early atherosclerotic lesions in an arterial bifurcation in humans. , 2009, Acta pathologica et microbiologica Scandinavica. Section A, Pathology.

[2]  R S Reneman,et al.  Methods to evaluate the sample volume of pulsed Doppler systems. , 1984, Ultrasound in medicine & biology.

[3]  J. Jakimowicz,et al.  Noninvasive Evaluation of Carotid Artery Stenosis— Comparison of Direct and Indirect Techniques , 1984 .

[4]  Arnold P. G. Hoeks,et al.  A Novel Frequency Estimator for Sampled Doppler Signals , 1984, IEEE Transactions on Biomedical Engineering.

[5]  M. Motomiya,et al.  Flow Patterns in the Human Carotid Artery Bifurcation , 1984, Stroke.

[6]  R. Reneman,et al.  Limitations of Doppler spectral broadening in the early detection of carotid artery disease due to the size of the sample volume. , 1983, Ultrasound in medicine & biology.

[7]  C. Zarins,et al.  Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress , 1983, Circulation research.

[8]  D. Ku,et al.  Pulsatile Flow in a Model Carotid Bifurcation , 1983, Arteriosclerosis.

[9]  R. Reneman What measurements are necessary for a comprehensive evaluation of the peripheral arterial circulation? , 1981, Cardiovascular diseases.

[10]  M D Nowak,et al.  Flow Studies in a Model Carotid Bifurcation , 1981, Arteriosclerosis.

[11]  R.S. Reneman,et al.  A Multigate Pulsed Doppler System with Serial Data Processing , 1981, IEEE Transactions on Sonics and Ultrasonics.

[12]  G. Hutchins,et al.  Correlation between intimal thickness and fluid shear in human arteries. , 1981, Atherosclerosis.

[13]  D J Phillips,et al.  Detection of carotid occlusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis. , 1979, Surgery.

[14]  M. Anliker,et al.  Noninvasive Measurement of Velocity Profiles and Blood Flow in the Common Carotid Artery by Pulsed Doppler Ultrasound , 1976, Stroke.

[15]  C. J. Ruissen,et al.  Transcutaneous detection of relative changes in artery diameter. , 1985, Ultrasound in medicine & biology.

[16]  R. Reneman,et al.  Serum HDL/total cholesterol ratio and blood pressure in asymptomatic atherosclerotic lesions of the cervical carotid arteries in men. , 1985, Stroke.

[17]  F. M. Greene,et al.  Flow velocity patterns in the carotid bifurcations of young, presumed normal subjects. , 1983, Ultrasound in medicine & biology.

[18]  K W Beach,et al.  Evaluating carotid artery disease. The concordance between pulsed Doppler/spectrum analysis and angiography. , 1983, Ultrasound in medicine & biology.

[19]  D. Giddens,et al.  Steady flow in a model of the human carotid bifurcation. Part II--laser-Doppler anemometer measurements. , 1982, Journal of biomechanics.

[20]  S. Rittgers,et al.  Real-time Doppler spectrum analysis: predictive value in defining operable carotid artery disease. , 1982, Archives of surgery.

[21]  P. Breslau Ultrasonic duplex scanning in the evaluation of carotid artery disease , 1982 .

[22]  R. Reneman,et al.  Noninvasive detection of atherosclerotic lesions in cervical carotid arteries at an early stage of the disease. , 1982, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[23]  A.P.G. Hoeks,et al.  On the development of a multi-gate pulsed Doppler system with serial data-processing , 1982 .

[24]  D. Giddens,et al.  Steady flow in a model of the human carotid bifurcation. Part I--flow visualization. , 1982, Journal of biomechanics.

[25]  F. M. Greene,et al.  Computer based pattern recognition of carotid arterial disease using pulsed Doppler ultrasound. , 1982, Ultrasound in medicine & biology.

[26]  D. Strandness,et al.  Evaluation of carotid bifurcation disease: the role of common carotid artery velocity patterns. , 1982, Archives of surgery.

[27]  R. Reneman,et al.  Local Doppler audio spectra in normal and stenosed carotid arteries in man. , 1979, Ultrasound in medicine & biology.