Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.

BACKGROUND Extent and orientation of interfragmentary movement (IFM) are crucially affecting course and quality of fracture healing. The effect of different configurations for implant fixation on successful fracture healing remain unclear. We hypothesize that screw type and configuration of locking plate fixation profoundly influences stiffness and IFM for a given load in a distal femur fracture model. METHODS Simple analytical models are presented to elucidate the influence of fixation configuration on construct stiffness. Models were refined with a consistent single-patient-data-set to create finite-element femur models. Locking plate fixation of a distal femoral 10mm-osteotomy (comminution model) was fitted with rigid locking screws (rLS) or semi-rigid locking screws (sLS). Systematic variations of screw placements in the proximal fragment were tested. IFM was quantitatively assessed and compared for different screw placements and screw types. RESULTS Different screw allocations significantly affect IFM in a locking plate construct. LS placement of the first screw proximal to the fracture (plate working length, PWL) has a significant effect on axial IFM (p < 0.001). Replacing rLS with sLS caused an increase (p < 0.001) of IFM under the plate (cis-cortex) between +8.4% and +28.1% for the tested configurations but remained constant medially (<1.1%, trans-cortex). Resultant shear movements markedly increased at fracture level (p < 0.001) to the extent that plate working length increased. The ratio of shear/axial IFM was found to enhance for longer PWL. sLS versus rLS lead to significantly smaller ratios of shear/axial IFM at the cis-cortex for PWL of ≥ 62 mm (p ≤ 0.003). CONCLUSION Mechanical frame conditions can be significantly influenced by type and placement of the screws in locking plate osteosynthesis of the distal femur. By varying plate working length stiffness and IFM are modulated. Moderate axial and concomitantly low shear IFM could not be achieved through changes in screw placement alone. In the present transverse osteotomy model, ratio of shear/axial IFM with simultaneous moderate axial IFM is optimized by the use of appropriate plate working length of about 42-62 mm. Fixation with sLS demonstrated significantly more axial IFM underneath the plate and may further contribute to compensation of asymmetric straining.

[1]  T. Apivatthakakul,et al.  The safety and feasibility of minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur: A cadaveric injection study. , 2015, Injury.

[2]  B. MacDonald,et al.  Predicting the external formation of callus tissues in oblique bone fractures: idealised and clinical case studies , 2013, Biomechanics and modeling in mechanobiology.

[3]  J Kenwright,et al.  The influence of induced micromovement upon the healing of experimental tibial fractures. , 1985, The Journal of bone and joint surgery. British volume.

[4]  S. Döbele,et al.  DLS 5.0 - The Biomechanical Effects of Dynamic Locking Screws , 2014, PloS one.

[5]  Rainer Burgkart,et al.  The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness , 2010, Langenbeck's Archives of Surgery.

[6]  J. García-Aznar,et al.  An interface finite element model can be used to predict healing outcome of bone fractures. , 2014, Journal of the mechanical behavior of biomedical materials.

[7]  J. McArthur,et al.  Distal femoral fractures: The need to review the standard of care. , 2015, Injury.

[8]  William M. Ricci,et al.  Risk Factors for Failure of Locked Plate Fixation of Distal Femur Fractures: An Analysis of 335 Cases , 2014, Journal of orthopaedic trauma.

[9]  M. Moazen,et al.  The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures. , 2015, Injury.

[10]  Seung-Jae Lim,et al.  Outcomes of long retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty , 2013, Archives of Orthopaedic and Trauma Surgery.

[11]  B. Rahn,et al.  Fracture healing in biological plate osteosynthesis. , 1998, Injury.

[12]  Michael J. Beltran,et al.  Management of distal femur fractures with modern plates and nails: state of the art. , 2015, Journal of orthopaedic trauma.

[13]  John M. O’Byrne,et al.  Locking compression plate breakage and fracture non-union: a finite element study of three patient-specific cases , 2012, European Journal of Orthopaedic Surgery & Traumatology.

[14]  L. Claes,et al.  The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation. , 1998, Clinical biomechanics.

[15]  M. Ehlinger,et al.  Distal femur fractures. Surgical techniques and a review of the literature. , 2013, Orthopaedics & traumatology, surgery & research : OTSR.

[16]  P. Tornetta,et al.  Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort , 2013, Journal of Orthopaedic Surgery and Research.

[17]  B. MacDonald,et al.  Predicting the external formation of a bone fracture callus: an optimisation approach , 2012, Computer methods in biomechanics and biomedical engineering.

[18]  Georg N Duda,et al.  Instability prolongs the chondral phase during bone healing in sheep. , 2006, Bone.

[19]  Lutz Claes,et al.  Prediction of fracture healing under axial loading, shear loading and bending is possible using distortional and dilatational strains as determining mechanical stimuli , 2013, Journal of The Royal Society Interface.

[20]  L. Claes,et al.  Numerical Simulation of Callus Healing for Optimization of Fracture Fixation Stiffness , 2014, PloS one.

[21]  Zsolt J Balogh,et al.  Indications and limitations of locked plating. , 2009, Injury.

[22]  M. Bottlang,et al.  Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation , 2010, Journal of orthopaedic trauma.

[23]  L. Claes,et al.  Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating. , 2014, Injury.

[24]  Lutz Claes,et al.  Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone , 2005, Osteoporosis International.

[25]  L. Claes Biomechanical Principles and Mechanobiologic Aspects of Flexible and Locked Plating , 2011, Journal of orthopaedic trauma.

[26]  Stephan M Perren,et al.  Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. , 2002, The Journal of bone and joint surgery. British volume.

[27]  Damien Lacroix,et al.  Simulation of fracture healing in the tibia: Mechanoregulation of cell activity using a lattice modeling approach , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[28]  B. MacDonald,et al.  Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced? , 2013, Journal of orthopaedics.

[29]  William R Taylor,et al.  Mechanical conditions in the initial phase of bone healing. , 2006, Clinical biomechanics.

[30]  G N Duda,et al.  The course of bone healing is influenced by the initial shear fixation stability , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[31]  Larry A. Taber To the readers of this BMMB/10237 issue , 2013 .

[32]  G. Hofmann,et al.  Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study. , 2011, Clinical biomechanics.

[33]  Georg N Duda,et al.  Initial vascularization and tissue differentiation are influenced by fixation stability , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  S. Gilbert,et al.  The development of the distal femur Less Invasive Stabilization System (LISS). , 2001, Injury.

[35]  Ulrich Dieter,et al.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? , 2003, Injury.

[36]  K. Schaser,et al.  Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading. , 2015, Clinical biomechanics.

[37]  Georg N Duda,et al.  Timely fracture-healing requires optimization of axial fixation stability. , 2007, The Journal of bone and joint surgery. American volume.

[38]  J. L. Marsh,et al.  Locking Plates for Distal Femur Fractures: Is There a Problem With Fracture Healing? , 2011, Journal of orthopaedic trauma.

[39]  T. Smith,et al.  The clinical and radiological outcomes of the LISS plate for distal femoral fractures: a systematic review. , 2009, Injury.

[40]  S. Kim,et al.  Overlapping intramedullary nailing after failed minimally invasive locked plating for osteoporotic distal femur fractures--Report of 2 cases. , 2015, Injury.