The true cyclotron frequency for particles and ions in a Penning trap

The true cyclotron frequency of a particle or ion, needed for mass spectrometry and other accurate measurements in a Penning trap, cannot be measured directly. It is not one of the oscillation frequencies of the trapped particle, and the three oscillation frequencies that can be measured vary with the misalignment and the harmonic distortion of the trap potential. Two methods to determine the cyclotron frequency are discussed. First, when all three eigenfrequencies of a trapped particle can be measured, the true cyclotron frequency is given by the prescription of the Brown–Gabrielse invariance theorem. This prescription makes possible a surprising number of the most accurate measurements in particle, nuclear and atomic physics because it accounts exactly for the lowest order electrostatic imperfections and magnetic misalignments. Second, when less accuracy is required, as when the masses of unstable nuclei are measured, a single sideband frequency is often measured instead—the frequency of a driving force that optimally couples two of the motions of the ion in the trap. A missing theoretical justification for this alternate method is provided using an expansion of the same invariance theorem. A remarkable suppression of systematic measurement errors is predicted, showing why these are not larger than reported measurement uncertainties, despite the contrary indication of simple estimates.

[1]  H. Kluge,et al.  Ramsey technique applied in a Penning trap mass spectrometer , 1992 .

[2]  G. Bollen Mass measurements of short-lived nuclides with ion traps , 2001 .

[3]  Hartmut Häffner,et al.  New determination of the electron's mass. , 2001, Physical review letters.

[4]  G Gabrielse,et al.  New measurement of the electron magnetic moment using a one-electron quantum cyclotron. , 2006, Physical review letters.

[5]  L. Schweikhard,et al.  Carbon-cluster mass calibration at SHIPTRAP , 2007 .

[6]  Van Dyck,et al.  Determination of the electron's atomic mass and the proton/electron mass ratio via Penning trap mass spectroscopy. , 1995, Physical review letters.

[7]  Alexander Herlert,et al.  ISOLTRAP: An on-line Penning trap for mass spectrometry on short-lived nuclides , 2008 .

[8]  E. Sauvan,et al.  From direct to absolute mass measurements: A study of the accuracy of ISOLTRAP , 2003 .

[9]  R. Dyck,et al.  The UW-PTMS , 2007 .

[10]  M. Kretzschmar The Ramsey method in high-precision mass spectrometry with Penning traps: Theoretical foundations , 2007 .

[11]  K. Blaum,et al.  New mass value for 7Li. , 2006, Physical review letters.

[12]  David Hanneke,et al.  Erratum: New Determination of the Fine Structure Constant from the Electron g Value and QED [Phys. Rev. Lett. 97, 030802 (2006)] , 2007 .

[13]  Simon Rainville,et al.  An Ion Balance for Ultra-High-Precision Atomic Mass Measurements , 2004, Science.

[14]  F. Ames,et al.  Accurate mass measurements of very short-lived nuclei , 2002 .

[15]  E. G. Myers,et al.  Mass and double-beta-decay Q value of Xe-136 , 2007 .

[16]  J. Rissanen,et al.  Q_EC values of the Superallowed beta Emitters 50Mn and 54Co , 2007 .

[17]  Van Dyck,et al.  New high-precision comparison of electron and positron g factors. , 1987, Physical review letters.

[18]  W. Quint,et al.  Electronic g factor of hydrogenlike oxygen 16O7+. , 2004, Physical review letters.

[19]  D. Pritchard,et al.  Cyclotron frequency shifts arising from polarization forces , 2004, Nature.

[20]  G. Werth,et al.  PRECISION NUCLEAR MEASUREMENTS WITH ION TRAPS , 2003 .

[21]  K. Blaum,et al.  The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results , 2007, physics/0701236.

[22]  Klaus Blaum,et al.  High-accuracy mass spectrometry with stored ions , 2006 .

[23]  R. Schuch,et al.  SMILETRAP—A Penning trap facility for precision mass measurements using highly charged ions , 2002 .

[24]  E. G. Myers,et al.  Dipole moment of PH+ and the atomic masses of 28Si, 31P by comparing cyclotron frequencies of two ions simultaneously trapped in a penning trap. , 2008, Physical review letters.

[25]  H. Kluge,et al.  Quadrupole excitation of stored ion motion at the true cyclotron frequency , 1995 .

[26]  Lowell S. Brown,et al.  Geonium theory: Physics of a single electron or ion in a Penning trap , 1986 .

[27]  G. Gabrielse,et al.  New measurement of the electron magnetic moment and the fine structure constant. , 2006, Physical review letters.

[28]  G. Bollen,et al.  The accuracy of heavy‐ion mass measurements using time of flight‐ion cyclotron resonance in a Penning trap , 1990 .

[29]  G Gabrielse,et al.  New determination of the fine structure constant from the electron value and QED. , 2006, Physical review letters.

[30]  A. Khabbaz,et al.  Precision Mass Spectroscopy of the Antiproton and Proton Using Simultaneously Trapped Particles , 1999 .

[31]  H. Häffner,et al.  High-accuracy measurement of the magnetic moment anomaly of the electron bound in hydrogenlike carbon. , 2000, Physical review letters.

[32]  R. Dyck,et al.  The UW-PTMS: Systematic studies, measurement progress, and future improvements , 2006 .

[33]  H. Kalinowsky,et al.  A direct determination of the proton electron mass ratio , 1980 .

[34]  G. Gabrielse,et al.  Precision spectroscopy of a charged particle in an imperfect Penning trap , 1982 .

[35]  Boyce,et al.  Mode coupling in a Penning trap: pi pulses and a classical avoided crossing. , 1990, Physical review. A, Atomic, molecular, and optical physics.

[36]  E. Sauvan,et al.  Masses of 32Ar and 33Ar for fundamental tests. , 2003, Physical review letters.

[37]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[38]  Boyce,et al.  Accurate atomic masses for fundamental metrology. , 1994, Physical review letters.