Level set based reconstruction algorithm for EIT lung images

We show the first clinical results using the level-set-based reconstruction algorithm for electrical impedance tomography (EIT) data. The level-set-based reconstruction method (LSRM) allows the reconstruction of non-smooth interfaces between image regions, which are typically smoothed by traditional voxel-based reconstruction methods (VBRMs). We develop a time difference formulation of the LSRM for 2D images. The proposed reconstruction method is applied to reconstruct clinical EIT data of a slow flow inflation pressure-volume manoeuvre in lung-healthy and adult lung-injury patients. Images from the LSRM and the VBRM are compared. The results show comparable reconstructed images, but with an improved ability to reconstruct sharp conductivity changes in the distribution of lung ventilation using the LSRM.

[1]  I. Frerichs,et al.  Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights. , 2001, Journal of applied physiology.

[2]  Inéz Frerichs,et al.  Electrical Impedance Tomography in Acute Respiratory Distress Syndrome , 2010 .

[3]  M. Soleimani,et al.  Level set reconstruction of conductivity and permittivity from boundary electrical measurements using experimental data , 2006 .

[4]  Manuchehr Soleimani,et al.  Level set based reconstruction algorithm for EIT lung images , 2011 .

[5]  Bin He,et al.  A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity , 2006, Physics in medicine and biology.

[6]  Torleif Dahlin,et al.  Short note on electrode charge‐up effects in DC resistivity data acquisition using multi‐electrode arrays , 2000 .

[7]  K. Paulsen,et al.  Arbitrary geometry patient interfaces for breast cancer detection and monitoring with electrical impedance tomography , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Manuchehr Soleimani,et al.  A Narrow-Band Level Set Method Applied to EIT in Brain for Cryosurgery Monitoring , 2006, IEEE Transactions on Biomedical Engineering.

[9]  Hugh McCann,et al.  Krylov subspace iterative techniques: on the detection of brain activity with electrical impedance tomography , 2002, IEEE Transactions on Medical Imaging.

[10]  I Frerichs,et al.  Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. , 2000, Physiological measurement.

[11]  R. Barker,et al.  Rapid least-squares inversion of apparent resistivity pseudosections , 1994 .

[12]  Manuchehr Soleimani,et al.  Shape based reconstruction of experimental data in 3D electrical capacitance tomography , 2010 .

[13]  E. Miller,et al.  A shape reconstruction method for electromagnetic tomography using adjoint fields and level sets , 2000 .

[14]  M. Soleimani Level-Set Method Applied to Magnetic Induction Tomography Using Experimental Data , 2007 .

[15]  Andy Adler,et al.  Regional lung opening and closing pressures in patients with acute lung injury. , 2012, Journal of critical care.

[16]  Dominique Lesselier,et al.  Level set methods for inverse scattering—some recent developments , 2009 .

[17]  James A. Sethian,et al.  Level Set Methods and Fast Marching Methods , 1999 .

[18]  Xuecheng Tai,et al.  Inverse Problems: Exercices , 2009 .

[19]  Hugh McCann,et al.  Sub-second functional imaging by Electrical Impedance Tomography , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  Stanley Osher,et al.  Level Set Methods , 2003 .

[21]  Anton Vonk-Noordegraaf,et al.  Stroke volume response during exercise measured by acetylene uptake and MRI , 2007, Physiological measurement.

[22]  Gunther Uhlmann,et al.  Electrical impedance tomography and Calderón's problem , 2009 .

[23]  Eric L. Miller,et al.  Recent work in shape-based methods for diffusive inverse problems , 2002, IEEE Antennas and Propagation Society International Symposium (IEEE Cat. No.02CH37313).

[24]  John E. McFee,et al.  Electrical Impedance Tomographic Imaging of Buried Landmines , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[25]  J. Sethian,et al.  Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations , 1988 .

[26]  William R B Lionheart,et al.  GREIT: a unified approach to 2D linear EIT reconstruction of lung images , 2009, Physiological measurement.

[27]  Manuchehr Soleimani,et al.  Electrical impedance tomography imaging using a priori ultrasound data , 2006, Biomedical engineering online.

[28]  O. Dorn,et al.  Level set methods for inverse scattering , 2006 .

[29]  A. Adler,et al.  Temporal image reconstruction in electrical impedance tomography , 2007, Physiological measurement.

[30]  T Schröder,et al.  A simple method to check the dynamic performance of electrical impedance tomography systems. , 2000, Physiological measurement.

[31]  R. Barker,et al.  Practical techniques for 3D resistivity surveys and data inversion1 , 1996 .

[33]  R. Barker,et al.  Rapid least-squared inversion of apparent resisitivity pseudosections by a quasi-Newton method , 1996 .

[34]  S. Osher,et al.  Geometric Level Set Methods in Imaging, Vision, and Graphics , 2011, Springer New York.

[35]  Andy Adler,et al.  Electrical impedance tomography: regularized imaging and contrast detection , 1996, IEEE Trans. Medical Imaging.

[36]  David Isaacson,et al.  NOSER: An algorithm for solving the inverse conductivity problem , 1990, Int. J. Imaging Syst. Technol..

[37]  T. Chan,et al.  Level set and total variation regularization for elliptic inverse problems with discontinuous coefficients , 2004 .

[38]  F. Santosa A Level-set Approach Inverse Problems Involving Obstacles , 1995 .

[39]  S. Osher,et al.  Algorithms Based on Hamilton-Jacobi Formulations , 1988 .

[40]  F. Santosa,et al.  Reconstruction of a two-dimensional binary obstacle by controlled evolution of a level-set , 1998 .

[41]  Miguel Moscoso,et al.  Mathematical and Computer Modelling ( ) – Mathematical and Computer Modelling Detecting and Imaging Dielectric Objects from Real Data: a Shape-based Approach , 2022 .