Influence of exposure parameters and iterative reconstruction on automatic airway segmentation and analysis on MDCT—An ex vivo phantom study

Objectives To evaluate the influence of exposure parameters and raw-data-based iterative reconstruction (IR) on computer-aided segmentation and quantitative analysis of the tracheobronchial tree on multidetector computed tomography (MDCT). Material and methods 10 porcine heart-lung-explants were mounted inside a dedicated chest phantom. MDCT was performed at 120kV and 80kV with 120, 60, 30 and 12 mAs each. All scans were reconstructed with filtered back projection (FBP) or IR, resulting in a total of 160 datasets. The maximum number of detected airway segments, most peripheral airway generation detected, generation-specific airway wall thickness (WT), total diameter (TD) and normalized wall thickness (pi10) were compared. Results The number of detected airway segments decreased slightly with dose (324.8±118 at 120kV/120mAs vs. 288.9±130 at 80kV/30mAs with FBP, p<0.05) and was not changed by IR. The 20th generation was constantly detected as most peripheral. WT did not change significantly with exposure parameters and reconstruction algorithm across all generations: range 1st generation 2.4–2.7mm, 5th 1.0–1.1mm, and 10th 0.7mm with FBP; 1st 2.3–2.4mm, 5th 1.0–1.1mm, and 10th 0.7–0.8mm with IR. pi10 was not affected as well (range 0.32–0.34mm). Conclusions Exposure parameters and IR had no relevant influence on measured airway parameters even for WT <1mm. Thus, no systematic errors would be expected using automatic airway analysis with low-dose MDCT and IR.

[1]  Joyce D. Schroeder,et al.  Chronic obstructive pulmonary disease: lobe-based visual assessment of volumetric CT by Using standard images--comparison with quantitative CT and pulmonary function test in the COPDGene study. , 2013, Radiology.

[2]  David Couper,et al.  SPIROMICS Protocol for Multicenter Quantitative Computed Tomography to Phenotype the Lungs. , 2016, American journal of respiratory and critical care medicine.

[3]  Seok Jeong Lee,et al.  Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction , 2014, European Radiology.

[4]  Stephen Lam,et al.  Quantitative assessment of the airway wall using computed tomography and optical coherence tomography. , 2009, Proceedings of the American Thoracic Society.

[5]  Christoph Düber,et al.  Fully Automated Extraction of Airways from CT Scans Based on Self-Adapting Region Growing , 2009 .

[6]  R. Smith,et al.  Bronchial tree Architecture in Mammals of Diverse Body Mass , 2014 .

[7]  M. Hasegawa,et al.  Relationship between improved airflow limitation and changes in airway calibre induced by inhaled anticholinergic agents in COPD , 2008, Thorax.

[8]  S. Holm A Simple Sequentially Rejective Multiple Test Procedure , 1979 .

[9]  Jürgen Biederer,et al.  Artificial thorax for MR imaging studies in porcine heart-lung preparations. , 2003, Radiology.

[10]  M. Hasegawa,et al.  Airflow limitation and airway dimensions in chronic obstructive pulmonary disease. , 2006, American journal of respiratory and critical care medicine.

[11]  [Quantification of pulmonary emphysema in multislice-CT using different software tools]. , 2006, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[12]  Guang-Hong Chen,et al.  Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study. , 2015, Medical physics.

[13]  Yi Zhang,et al.  Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels. , 2015, Radiology.

[14]  Jiang Hsieh,et al.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. , 2010, Radiology.

[15]  C R Muirhead,et al.  Evidence for curvilinearity in the cancer incidence dose-response in the Japanese atomic bomb survivors. , 1996, International journal of radiation biology.

[16]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[17]  Yasutaka Nakano,et al.  Airway wall thickening and emphysema show independent familial aggregation in chronic obstructive pulmonary disease. , 2008, American journal of respiratory and critical care medicine.

[18]  V. Kim,et al.  Chronic bronchitis and chronic obstructive pulmonary disease. , 2013, American journal of respiratory and critical care medicine.

[19]  H. Kauczor,et al.  CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom: influence of exposure parameters and iterative reconstruction on reproducibility. , 2013, European journal of radiology.

[20]  Jin Mo Goo,et al.  Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction , 2014, European Radiology.

[21]  Hans-Ulrich Kauczor,et al.  Variation of Densitometry on Computed Tomography in COPD – Influence of Different Software Tools , 2014, PloS one.

[22]  C. Streffer,et al.  Biological effects after prenatal irradiation (embryo and fetus). A report of the International Commission on Radiological Protection. , 2003, Annals of the ICRP.

[23]  Oliver Weinheimer,et al.  MDCT assessment of airway wall thickness in COPD patients using a new method: correlations with pulmonary function tests , 2008, European Radiology.

[24]  Stefan Ulzheimer,et al.  CT dose and image quality in the last three scanner generations. , 2013, World journal of radiology.

[25]  H. Kauczor,et al.  Computed Tomographic Imaging of the Airways in COPD and Asthma , 2011, Journal of thoracic imaging.

[26]  Bertram J Jobst,et al.  Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom: influence of exposure parameters and iterative reconstruction. , 2015, European journal of radiology.

[27]  Thomas Flohr,et al.  Low-dose CT of the lung: potential value of iterative reconstructions , 2012, European Radiology.

[28]  A. Gulsvik,et al.  Quantitative computed tomography: emphysema and airway wall thickness by sex, age and smoking , 2009, European Respiratory Journal.

[29]  P. Calverley,et al.  Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summary. , 2007, American journal of respiratory and critical care medicine.

[30]  S. Lam,et al.  New and current clinical imaging techniques to study chronic obstructive pulmonary disease. , 2009, American journal of respiratory and critical care medicine.

[31]  E. Hart,et al.  Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: does one size fit all? , 2013, European journal of radiology.

[32]  Craig J. Galbán,et al.  Fully automated lobe-based airway taper index calculation in a low dose MDCT CF study over 4 time-points , 2017, Medical Imaging.

[33]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[34]  Christoph Düber,et al.  Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings. , 2012, European journal of radiology.

[35]  Hans-Ulrich Kauczor,et al.  About Objective 3-D Analysis of Airway Geometry in Computerized Tomography , 2008, IEEE Transactions on Medical Imaging.

[36]  Nicola A Hanania,et al.  Chronic obstructive pulmonary disease exacerbations in the COPDGene study: associated radiologic phenotypes. , 2011, Radiology.

[37]  Hans-Ulrich Kauczor,et al.  Automatic Airway Analysis on Multidetector Computed Tomography in Cystic Fibrosis: Correlation With Pulmonary Function Testing , 2013, Journal of thoracic imaging.

[38]  Edwin K Silverman,et al.  CT-Definable Subtypes of Chronic Obstructive Pulmonary Disease: A Statement of the Fleischner Society. , 2015, Radiology.

[39]  H. Kauczor,et al.  Quantifizierung des Lungenemphysems in der Mehrschicht-CT mittels verschiedener Softwareverfahren , 2006 .

[40]  J. Remy,et al.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients , 2011, European Radiology.

[41]  M. Prokop,et al.  The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions , 2012, European Radiology.

[42]  Tim Leiner,et al.  Systematic error in lung nodule volumetry: effect of iterative reconstruction versus filtered back projection at different CT parameters. , 2012, AJR. American journal of roentgenology.

[43]  Jürgen Biederer,et al.  Pulmonary Emphysema in Cystic Fibrosis Detected by Densitometry on Chest Multidetector Computed Tomography , 2013, PloS one.