Comprehensive Monte Carlo calculation of the point spread function for a commercial a-Si EPID.

Images produced by commercial amorphous silicon electronic portal imaging devices (a-Si EPIDs) are subject to multiple blurring processes. Implementation of these devices for fluence measurement requires that the blur be removed from the images. A standard deconvolution operation can be performed to accomplish this assuming the blur kernel is spatially invariant and accurately known. This study determines a comprehensive blur kernel for the Varian aS500 EPID. Monte Carlo techniques are used to derive a dose kernel and an optical kernel, which are then combined to yield an overall blur kernel for both 6 and 15 MV photon beams. Experimental measurement of the line spread function (LSF) is used to verify kernel shape. Kernel performance is gauged by comparing EPID image profiles with in-air dose profiles measured using a diamond detector (approximating fluence) both before and after the EPID images have been deconvolved. Quantitative comparisons are performed using the chi metric, an extension of the well-known y metric, using acceptance criteria of 0.0784 cm (1 pixel width) distance-to-agreement (deltad) and 2% of the relative central axis fluence (deltaD). Without incorporating any free parameters, acceptance was increased from 49.0% of pixels in a cross-plane profile for a 6 MV 10 x 10 cm2 open field to 92.0%. For a 10 x 10 cm2 physically wedged field, acceptance increased from 40.3% to 73.9%. The effect of the optical kernel was found to be negligible for these chi acceptance parameters, however for (deltaD= 1%, deltad = 0.0784 cm) we observed an improvement from 66.1% (without) to 78.6% (with) of chi scores <1 (from 20.6% before deconvolution). It is demonstrated that an empirical kernel having a triple exponential form or a semiempirical kernel based on a simplified model of the detector stack can match the performance of the comprehensive kernel.

[1]  J. Rogers,et al.  A simulation to model position encoding multicrystal PET detectors , 1995 .

[2]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[3]  Ron S Sloboda,et al.  Compensator quality control with an amorphous silicon EPID. , 2003, Medical physics.

[4]  B. Heijmen,et al.  Portal dose measurement in radiotherapy using an electronic portal imaging device (EPID). , 1995, Physics in medicine and biology.

[5]  J. Siebers,et al.  Verification of the optimal backscatter for an aSi electronic portal imaging device , 2004, Physics in medicine and biology.

[6]  C. Ling,et al.  Using the frame averaging of aS500 EPID for IMRT verification , 2003, Journal of applied clinical medical physics.

[7]  O Dössel,et al.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy. , 1999, Medical physics.

[8]  B. Fallone,et al.  Investigation into the physical characteristics of active matrix flat panel imagers for radiotherapy. , 2001, Medical physics.

[9]  B. McCurdy,et al.  Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device. , 2001, Medical physics.

[10]  W F Hanson,et al.  A generic off-axis energy correction for linac photon beam dosimetry. , 1998, Medical physics.

[11]  M L Giger,et al.  Investigation of basic imaging properties in digital radiography. 6. MTFs of II-TV digital imaging systems. , 1985, Medical physics.

[12]  M. Alber,et al.  A revision of the γ-evaluation concept for the comparison of dose distributions , 2003 .

[13]  P. Munro,et al.  X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays. , 1998, Medical physics.

[14]  J A Seibert,et al.  Scintillating fiber optic screens: a comparison of MTF, light conversion efficiency, and emission angle with Gd2O2S:Tb screens. , 1997, Medical physics.

[15]  G. Lubberts,et al.  Random Noise Produced by X-Ray Fluorescent Screens* , 1968 .

[16]  R. Mohan,et al.  Monte Carlo computation of dosimetric amorphous silicon electronic portal images. , 2004, Medical physics.

[17]  B G Fallone,et al.  Dosimetric IMRT verification with a flat-panel EPID. , 2003, Medical physics.

[18]  K. Lam,et al.  Relative dosimetry using active matrix flat-panel imager (AMFPI) technology. , 1999, Medical physics.

[19]  M. Bucciolini,et al.  An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams. , 2002, Medical physics.

[20]  Glenn F. Knoll,et al.  Light collection in scintillation detector composites for neutron detection , 1988 .

[21]  I. Kawrakow Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations. , 2000, Medical physics.

[22]  D W O Rogers,et al.  Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. , 2002, Medical physics.

[23]  M B Aufderheide,et al.  Blurring artifacts in megavoltage radiography with a flat-panel imaging system: comparison of Monte Carlo simulations with measurements. , 2002, Medical physics.