Feasibility study of grouted splice connector under tensile load

The conventional bar lapping approach to connect steel bars requires long development length and always leads to bar congestion problems. For this reason, grouted splice connectors are used to confine the grout surrounding the bars to improve the bond between the grout and the bars. Four series of specimens with a total of 35 specimens were tested under incremental tensile load. These specimens vary in terms of configurations and were assessed for feasibility in the aspects of bond strength, ductility response and failure modes. Equations are derived to evaluate the structural performance of the specimens. The typical modes of failure are bar tensile failure, grout-bar bond failure, grout-sleeve bond failure, and sleeve tensile failure. These failures reveal the factors to be considered during the design of a splice connector. Under confinement, the required anchorage length of the bars can be shortened to nearly nine times the diameter of the spliced bar.

[1]  Pietro G. Gambarova,et al.  Bond and Splitting: A Vexing Question , 1998, SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely.

[2]  Michael G. Oliva,et al.  Durable Fiber Reinforced Polymer Bar Splice Connections for Precast Concrete Structures , 2008 .

[3]  Keith Lynn Coogler Investigation of the Behavior of Offset Mechanical Splices , 2007 .

[4]  James Chinn,et al.  Lapped Splices in Reinforced ConcreteBeams , 1955 .

[5]  Ahmad Baharuddin Abd. Rahman,et al.  PERFORMANCE OF CS-SLEEVE UNDER DIRECT TENSILE LOAD: PART I: FAILURE MODES , 2008 .

[6]  Yukimasa Goto,et al.  CRACKS FORMED IN CONCRETE AROUND DEFORMED TENSION BARS , 1971 .

[7]  Ralejs Tepfers,et al.  A theory of bond applied to overlapped tensile reinforcement splices for deformed bars , 1973 .

[8]  Bilal S. Hamad,et al.  Comparative Bond Strength of Coated and Uncoated Barswith Different Rib Geometries , 1995 .

[9]  James L Noland,et al.  Computer-Aided Structural Engineering (CASE) Project: Decision Logic Table Formulation of ACI (American Concrete Institute) 318-77 Building Code Requirements for Reinforced Concrete for Automated Constraint Processing. Volume 1. , 1986 .

[10]  Ahmad Baharuddin Abd. Rahman,et al.  Performance of grouted sleeve connectors subjected to incremental tensile loads , 2010 .

[11]  Hsi Yoon Loh,et al.  Development of grouted splice sleeve and its performance under axial tension , 2008 .

[12]  Vitelmo V. Bertero,et al.  Local bond stress-slip relationships of deformed bars under generalized excitations : experimental results and analytical model , 1983 .

[13]  Vitelmo V. Bertero,et al.  Local bond stress-slip relationships of deformed bars under generalized excitations , 1982 .

[14]  Kent A. Harries,et al.  Experimental Study of Offset Mechanical Lap Splice Behavior , 2008 .

[15]  P. M. Ferguson,et al.  Reinforced Concrete Fundamentals , 1981 .

[16]  Maher K. Tadros,et al.  GROUT-FILLED PIPE SPLICES FOR PRECAST CONCRETE CONSTRUCTION , 1995 .

[17]  Robert L. Henry,et al.  Influence of Normal Pressure on Bond Strength , 1965 .

[18]  A. Jafari,et al.  Bond of cement grouted reinforcing bars under constant radial pressure , 2005 .

[19]  Claude Ethelbert Winn Tests of bond between concrete and steel , .

[20]  R. M. Mains Measurement of the Distribution of Tensile and Bond Stresses Along Reinforcing Bars , 1951 .

[21]  P. J. Robins,et al.  The influence of lateral pressure upon anchorage bond , 1984 .

[22]  Peter O Jansson,et al.  Evaluation of Grout-Filled Mechanical Splices for Precast Concrete Construction , 2008 .

[23]  Arthur P. Clark BOND OF CONCRETE REINFORCING BARS , 1949 .

[24]  John E. Breen,et al.  THE STRENGTH OF ANCHOR BARS: A REEVALUATION OF TEST DATA ON DEVELOPMENT LENGTH AND SPLICES , 1977 .

[25]  Parviz Soroushian,et al.  Bond of Deformed Bars to Concrete: Effects of Confinement and Strength of Concrete , 1991 .

[26]  S. J. Chamberlin,et al.  Spacing of Spliced Bars in Tension Pull-Out Specimens , 1952 .

[27]  Jen Hua Ling,et al.  Behaviour of grouted splice connections in precast concrete walls subjected to tensile, shear and flexural loads , 2011 .

[28]  Stephen Pessiki,et al.  Evaluation of effective prestress force in 28-year-old prestressed concrete bridge beams , 1996 .

[29]  Sami H. Rizkalla,et al.  Horizontal Connections for Precast Concrete Shear Walls Subjected to Cyclic Deformations Part 1: Mild Steel Connections , 1995 .

[30]  David Darwin,et al.  Effect of Deformation Height and Spacing on Bond Strength of Reinforcing Bars , 1993 .